Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitrex M410-L3H — CEC Solar Module Specifications

Manufacturer: Mitrex Registry: CEC Verified Engineering Specification

Mitrex M410-L3H is a 410.0 W STC (386.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.24% efficiency, 37.68 V Voc at 25 C, and 41.04 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
386.1 W
Voc @ 25C
37.68 V
Efficiency
21.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitrex M410-L3H Compare Against Peer CEC Listings?

Engineering position of Mitrex M410-L3H (410.0 W STC) vs. ASTORIOS Holding Inc ASTR108BDG-410W-US across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Mitrex M410-L3H pairs strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677) with 37.68 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,722 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ASTORIOS Holding Inc ASTR108BDG-410W-US offers a 410.0 W alternative.

Where Does Mitrex M410-L3H Fall Across Listed CEC Models?

Plots Mitrex M410-L3H at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitrex M410-L3H (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitrex M410-L3H: 410.0 W

What Dataset Percentiles Define Mitrex M410-L3H?

Benchmarks Mitrex M410-L3H on STC wattage, thermal PTC/STC retention, and 21.24 aperture conversion efficiency against CEC peers.

Mitrex M410-L3H Engineering BenchmarksPercentile comparison of Mitrex M410-L3H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.2%Module Efficiency21.24%

What Do the Dataset Ranks Show for Mitrex M410-L3H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitrex M410-L3H by Mitrex.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,440

21.24% Aperture Efficiency

Power density 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.04 V at -10 C (574.6 V string) and 42.0 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.6 m2 (415 sq ft) producing 7,722 W PTC; NEC 690.8 OCPD floor is 21.57 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.68 * (1 + (-0.255/100) * (-10 - 25)) = 41.04 V | OCPD = 1.56 * 13.83 = 21.57 A

Inputs from CEC Modules.csv for Mitrex M410-L3H: Voc=37.68 V, beta_Voc=-0.255%/C, Isc=13.83 A, STC=410.0 W, Area=1.93 m2.

Result: 14 panels max on 600 V (574.6 V); 20 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for Mitrex M410-L3H?

Laboratory test ratings recorded for Mitrex M410-L3H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mitrex M410-L3H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 386.1 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.17 V / 13.18 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.255 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.24% (1.93 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Mitrex M410-L3H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (415 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitrex M410-L3H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 312 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 415 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 519 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Mitrex Series?

Sibling wattage bins and frame colors grouped with Mitrex M410-L3H under Mitrex to prevent duplicate spec pages. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Mitrex M410-L3H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mitrex M400-L3H 400.0 W 376.5 W 37.08 V 30.59 V 20.73%
Mitrex M405-L3H 405.0 W 381.3 W 37.38 V 30.87 V 20.98%
Mitrex M410-L3H 410.0 W 386.1 W 37.68 V 31.17 V 21.24%
Mitrex M415-L3H 415.0 W 391.0 W 37.98 V 31.43 V 21.5%

How Many Mitrex M410-L3H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mitrex M410-L3H (beta_Voc -0.255%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.68V and beta_Voc=-0.255%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.0 V 14 panels 588.0 V 23 panels
-10 C (14 F) 41.04 V 14 panels 574.6 V 24 panels
0 C (32 F) 40.08 V 14 panels 561.1 V 24 panels
25 C (77 F STC) 37.68 V 15 panels 565.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Mitrex M410-L3H?

Closest cross-brand CEC competitors to Mitrex M410-L3H matched near 410.0 W STC and 37.68 V Voc, led by ASTORIOS Holding Inc ASTR108BDG-410W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
CSI Solar Co Ltd CS6R-410MB-HL
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitrex M410-L3H?

Evaluate Mitrex M410-L3H (410.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitrex M410-L3H reaches 42.0 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Mitrex M410-L3H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitrex M410-L3H 8 kW Residential Fit

Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 386.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitrex M410-L3H by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What fuse or breaker size does NEC 690.8 require for Mitrex M410-L3H?

Multiplying Mitrex M410-L3H's 13.83 A short-circuit current by 1.56 equals 21.57 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M410-L3H before finalizing component orders.

Can Mitrex M410-L3H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.04 V cold Voc at 14 F and handles 13.83 A Isc; string inverters cap Mitrex M410-L3H at 14 panels on 600 V.

Is Mitrex M410-L3H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M410-L3H rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.