Mitrex M395-B1F is a 395.0 W STC (364.3 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.75% efficiency, 48.3 V Voc at 25 C, and 52.78 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 364.3 W
- Voc @ 25C
- 48.3 V
- Efficiency
- 19.75%
How Does Mitrex M395-B1F Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitrex M395-B1F (Mono-c-Si) residential solar systems. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Homeowners evaluating Mitrex M395-B1F need 16 panels for 6 kW or 21 panels (452 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.265%/C) pushes open-circuit voltage to 52.78 V at 14 F and 54.06 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Mitrex M395-B1F Fall Across Listed CEC Models?
Comparison of Mitrex M395-B1F (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Mitrex M395-B1F?
Relative ranking of Mitrex M395-B1F across nameplate watts, 92.2% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Mitrex M395-B1F?
Summary of Mitrex M395-B1F output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.75% Aperture Efficiency
Power density 197.5 W/m2 (0.16 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.78 V at -10 C (580.6 V string) and 54.06 V at -20 C (11 max).
21 Panels = 8,295 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,650 W PTC; NEC 690.8 OCPD floor is 15.3 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.3 * (1 + (-0.265/100) * (-10 - 25)) = 52.78 V | OCPD = 1.56 * 9.81 = 15.3 A
Inputs from CEC Modules.csv for Mitrex M395-B1F: Voc=48.3 V, beta_Voc=-0.265%/C, Isc=9.81 A, STC=395.0 W, Area=2.0 m2.
Result: 11 panels max on 600 V (580.6 V); 21 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for Mitrex M395-B1F?
Complete CEC test sheet for Mitrex M395-B1F including Isc (9.81 A), Voc (48.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 364.3 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.1 V / 9.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.75% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Mitrex M395-B1F Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitrex M395-B1F.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 344 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 452 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 560 sq ft | $2,570 | $4,347 |
How Many Mitrex M395-B1F Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Mitrex M395-B1F (48.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.06 V | 11 panels | 594.7 V | 18 panels |
| -10 C (14 F) | 52.78 V | 11 panels | 580.6 V | 18 panels |
| 0 C (32 F) | 51.5 V | 11 panels | 566.5 V | 19 panels |
| 25 C (77 F STC) | 48.3 V | 12 panels | 579.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M395-B1F?
Four comparable CEC modules such as Auxin Solar AXNG1M395B (395.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXNG1M395B Auxin Solar |
395.0 W | Tie (0 W) | 48.33 V | 20.15% | 93.3% |
| Auxin Solar AXNG1M395W Auxin Solar |
395.0 W | Tie (0 W) | 48.33 V | 20.15% | 93.2% |
| Aptos Solar Technology LLC DNA-144-MF23-395W {Blk} Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 48.37 V | 19.63% | 90.7% |
| Aptos Solar Technology LLC DNA-144-MF23-395W {Wht} Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 48.37 V | 20.26% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Mitrex M395-B1F?
Evaluate Mitrex M395-B1F (395.0 W STC, 48.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M395-B1F reaches 54.06 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mitrex M395-B1F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M395-B1F 8 kW Residential Fit
Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXNG1M395B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 364.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M395-B1F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Why is Mitrex M395-B1F PTC wattage (364.3 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 364.3 W PTC (92.2% retention) across Mitrex M395-B1F's 2.0 m2 aperture.
Who should skip Mitrex M395-B1F on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Mitrex M395-B1F panels (452 sq ft) leave unusable roof gaps vs. Auxin Solar AXNG1M395B.
What is the 1,000 V commercial string limit for Mitrex M395-B1F?
On 1,000 V commercial inverters at -10 C (52.78 V cold Voc), Mitrex M395-B1F fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitrex M395-B1F.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)