Mitrex M440-H1H is a 440.0 W STC (409.8 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.47% efficiency, 49.53 V Voc at 25 C, and 54.7 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 409.8 W
- Voc @ 25C
- 49.53 V
- Efficiency
- 20.47%
How Does Mitrex M440-H1H Compare Against Peer CEC Listings?
How Mitrex Mitrex M440-H1H handles rooftop heat (409.8 W PTC), 8 kW sizing, and cold winter string voltage.
Mitrex builds the Mitrex M440-H1H (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). Compared against Bluesun Solar CoLtd BSM440M-72HBD (440.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Higher 49.53 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 17.39 A overcurrent floor served by a 20 A breaker.
Where Does Mitrex M440-H1H Fall Across Listed CEC Models?
Where Mitrex M440-H1H (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Mitrex M440-H1H?
Percentile placement of Mitrex M440-H1H across power density (204.7 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Mitrex M440-H1H?
Four critical engineering numbers homeowners and solar installers check first when reviewing Mitrex M440-H1H specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.47% Aperture Efficiency
Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.7 V at -10 C (547.0 V string) and 56.17 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 40.9 m2 (440 sq ft) producing 7,786 W PTC; NEC 690.8 OCPD floor is 17.39 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.53 * (1 + (-0.298/100) * (-10 - 25)) = 54.7 V | OCPD = 1.56 * 11.15 = 17.39 A
Inputs from CEC Modules.csv for Mitrex M440-H1H: Voc=49.53 V, beta_Voc=-0.298%/C, Isc=11.15 A, STC=440.0 W, Area=2.15 m2.
Result: 10 panels max on 600 V (547.0 V); 19 panels for 8 kW (440 sq ft).
What Are the Published CEC Specifications for Mitrex M440-H1H?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitrex M440-H1H. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 409.8 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.55 V / 10.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.298 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.47% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Mitrex M440-H1H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitrex M440-H1H (440.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 324 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 440 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 532 sq ft | $2,533 | $4,283 |
How Many Mitrex M440-H1H Modules Fit in a Cold-Weather String?
Maximum series module counts for Mitrex M440-H1H from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.17 V | 10 panels | 561.7 V | 17 panels |
| -10 C (14 F) | 54.7 V | 10 panels | 547.0 V | 18 panels |
| 0 C (32 F) | 53.22 V | 11 panels | 585.4 V | 18 panels |
| 25 C (77 F STC) | 49.53 V | 12 panels | 594.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M440-H1H?
Alternative CEC solar modules from competing brands near Mitrex M440-H1H (440.0 W), including Bluesun Solar CoLtd BSM440M-72HBD. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM440M-72HBD Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 50.0 V | 20.28% | 92.7% |
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | -5.0 W | 49.38 V | 20.71% | 92.3% |
| CSI Solar Co Ltd CS3Y-440PB-AG CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 51.2 V | 19.13% | 93.7% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | -5.0 W | 49.1 V | 20.62% | 93.7% |
What Are the Design Limits and Best-Fit Uses for Mitrex M440-H1H?
Evaluate Mitrex M440-H1H (440.0 W STC, 49.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M440-H1H reaches 56.17 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mitrex M440-H1H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M440-H1H 8 kW Residential Fit
Needs 19 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM440M-72HBD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 409.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M440-H1H by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What fuse or breaker size does NEC 690.8 require for Mitrex M440-H1H?
Multiplying Mitrex M440-H1H's 11.15 A short-circuit current by 1.56 equals 17.39 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M440-H1H before finalizing component orders.
Can Mitrex M440-H1H pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.7 V cold Voc at 14 F and handles 11.15 A Isc; string inverters cap Mitrex M440-H1H at 10 panels on 600 V.
Is Mitrex M440-H1H eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M440-H1H rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)