Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitrex M410-I3H — CEC Solar Module Specifications

Manufacturer: Mitrex Registry: CEC Verified Engineering Specification

Mitrex M410-I3H is a 410.0 W STC (381.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.25 V Voc at 25 C, and 40.94 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
381.7 W
Voc @ 25C
37.25 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitrex M410-I3H Compare Against Peer CEC Listings?

How Mitrex Mitrex M410-I3H handles rooftop heat (381.7 W PTC), 8 kW sizing, and cold winter string voltage.

Mitrex builds the Mitrex M410-I3H (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108 (410.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.45 A overcurrent floor served by a 25 A breaker.

Where Does Mitrex M410-I3H Fall Across Listed CEC Models?

Where Mitrex M410-I3H (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitrex M410-I3H (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitrex M410-I3H: 410.0 W

What Dataset Percentiles Define Mitrex M410-I3H?

Percentile placement of Mitrex M410-I3H across power density (210.3 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Mitrex M410-I3H Engineering BenchmarksPercentile comparison of Mitrex M410-I3H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.1%Module Efficiency21.03%

What Do the Dataset Ranks Show for Mitrex M410-I3H?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mitrex M410-I3H specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.94 V at -10 C (573.2 V string) and 41.99 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.45 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.283/100) * (-10 - 25)) = 40.94 V | OCPD = 1.56 * 13.75 = 21.45 A

Inputs from CEC Modules.csv for Mitrex M410-I3H: Voc=37.25 V, beta_Voc=-0.283%/C, Isc=13.75 A, STC=410.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (573.2 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Mitrex M410-I3H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitrex M410-I3H. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Mitrex M410-I3H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.7 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.25 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.75 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.75 V / 12.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.283 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Mitrex M410-I3H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitrex M410-I3H (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 315 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 420 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 525 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Mitrex Series?

All closely matched Mitrex wattages and cosmetic trims sharing the Mitrex M410-I3H architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Mitrex M410-I3H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mitrex M400-I3H 400.0 W 372.1 W 36.74 V 31.23 V 20.51%
Mitrex M405-I3H 405.0 W 376.9 W 36.94 V 31.49 V 20.77%
Mitrex M410-I3H 410.0 W 381.7 W 37.25 V 31.75 V 21.03%
Mitrex M415-I3H 415.0 W 386.5 W 37.52 V 32.05 V 21.28%

How Many Mitrex M410-I3H Modules Fit in a Cold-Weather String?

Maximum series module counts for Mitrex M410-I3H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.283%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.99 V 14 panels 587.9 V 23 panels
-10 C (14 F) 40.94 V 14 panels 573.2 V 24 panels
0 C (32 F) 39.89 V 15 panels 598.4 V 25 panels
25 C (77 F STC) 37.25 V 16 panels 596.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Mitrex M410-I3H?

Alternative CEC solar modules from competing brands near Mitrex M410-I3H (410.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.3 V 21.24% 92.1%
AXITEC AC-410MH/108VB
AXITEC
410.0 W Tie (0 W) 37.3 V 21.24% 92.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitrex M410-I3H?

Evaluate Mitrex M410-I3H (410.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitrex M410-I3H reaches 41.99 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Mitrex M410-I3H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitrex M410-I3H 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitrex M410-I3H by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

What fuse or breaker size does NEC 690.8 require for Mitrex M410-I3H?

Multiplying Mitrex M410-I3H's 13.75 A short-circuit current by 1.56 equals 21.45 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M410-I3H before finalizing component orders.

Can Mitrex M410-I3H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.94 V cold Voc at 14 F and handles 13.75 A Isc; string inverters cap Mitrex M410-I3H at 14 panels on 600 V.

Is Mitrex M410-I3H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M410-I3H rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.