AXITEC AC-410MH/108VB is a 410.0 W STC (377.8 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.24% efficiency, 37.3 V Voc at 25 C, and 40.9 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 377.8 W
- Voc @ 25C
- 37.3 V
- Efficiency
- 21.24%
How Does AXITEC AC-410MH/108VB Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-410MH/108VB (410.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E across 5,889 CEC Mono-c-Si solar modules.
Built with 54 Mono-c-Si cells, AXITEC AC-410MH/108VB pairs strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677) with 37.3 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,556 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E offers a 410.0 W alternative.
Where Does AXITEC AC-410MH/108VB Fall Across Listed CEC Models?
Plots AXITEC AC-410MH/108VB at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-410MH/108VB?
Benchmarks AXITEC AC-410MH/108VB on STC wattage, thermal PTC/STC retention, and 21.24 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-410MH/108VB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-410MH/108VB by AXITEC.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.24% Aperture Efficiency
Power density 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.9 V at -10 C (572.6 V string) and 41.93 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,556 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.3 * (1 + (-0.276/100) * (-10 - 25)) = 40.9 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for AXITEC AC-410MH/108VB: Voc=37.3 V, beta_Voc=-0.276%/C, Isc=13.7 A, STC=410.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (572.6 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for AXITEC AC-410MH/108VB?
Laboratory test ratings recorded for AXITEC AC-410MH/108VB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 377.8 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.2 V / 13.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.276 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.24% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-410MH/108VB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (415 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-410MH/108VB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 312 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 415 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 519 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-410MH/108VB under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-400MH/108VB | 400.0 W | 374.9 W | 37.07 V | 31.01 V | 20.62% |
| AXITEC AC-410MH/108VB | 410.0 W | 377.8 W | 37.3 V | 31.2 V | 21.24% |
| AXITEC AC-415MH/108VB | 415.0 W | 382.6 W | 37.4 V | 31.2 V | 21.5% |
How Many AXITEC AC-410MH/108VB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-410MH/108VB (beta_Voc -0.276%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.93 V | 14 panels | 587.0 V | 23 panels |
| -10 C (14 F) | 40.9 V | 14 panels | 572.6 V | 24 panels |
| 0 C (32 F) | 39.87 V | 15 panels | 598.0 V | 25 panels |
| 25 C (77 F STC) | 37.3 V | 16 panels | 596.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-410MH/108VB?
Closest cross-brand CEC competitors to AXITEC AC-410MH/108VB matched near 410.0 W STC and 37.3 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
410.0 W | Tie (0 W) | 37.3 V | 21.24% | 92.1% |
| Aptos Solar Technology LLC DNA-108-MF10-410W Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| CertainTeed CTM10410HC11-06 CertainTeed |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| Elin Energy (Sirius PV) ELNSM54M-HC-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.3% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-410MH/108VB?
Evaluate AXITEC AC-410MH/108VB (410.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-410MH/108VB reaches 41.93 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-410MH/108VB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-410MH/108VB 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-410MH/108VB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-410MH/108VB?
Multiplying AXITEC AC-410MH/108VB's 13.7 A short-circuit current by 1.56 equals 21.37 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can AXITEC AC-410MH/108VB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.9 V cold Voc at 14 F and handles 13.7 A Isc; string inverters cap AXITEC AC-410MH/108VB at 14 panels on 600 V.
Is AXITEC AC-410MH/108VB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-410MH/108VB rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)