Auxin Solar AXNG1M395B is a 395.0 W STC (368.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.15% efficiency, 48.33 V Voc at 25 C, and 52.69 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 368.4 W
- Voc @ 25C
- 48.33 V
- Efficiency
- 20.15%
How Does Auxin Solar AXNG1M395B Compare Against Peer CEC Listings?
Solar engineering breakdown for Auxin Solar AXNG1M395B: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Across 5,889 Mono-c-Si listings from Auxin Solar and peers, Auxin Solar AXNG1M395B stands 15.0 W below the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Higher 48.33 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Auxin Solar AXNG1M395B Fall Across Listed CEC Models?
Distribution marker showing Auxin Solar AXNG1M395B (395.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Auxin Solar AXNG1M395B?
Dataset percentiles tracking Auxin Solar AXNG1M395B power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Auxin Solar AXNG1M395B?
Benchmark highlights for Auxin Solar AXNG1M395B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.15% Aperture Efficiency
Power density 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.69 V at -10 C (579.6 V string) and 53.94 V at -20 C (11 max).
21 Panels = 8,295 W STC
Occupies 41.2 m2 (443 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 15.97 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.33 * (1 + (-0.258/100) * (-10 - 25)) = 52.69 V | OCPD = 1.56 * 10.24 = 15.97 A
Inputs from CEC Modules.csv for Auxin Solar AXNG1M395B: Voc=48.33 V, beta_Voc=-0.258%/C, Isc=10.24 A, STC=395.0 W, Area=1.96 m2.
Result: 11 panels max on 600 V (579.6 V); 21 panels for 8 kW (443 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXNG1M395B?
Official CEC datasheet figures for Auxin Solar AXNG1M395B (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 368.4 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.13 V / 9.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.258 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.15% (1.96 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXNG1M395B Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Auxin Solar AXNG1M395B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 338 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 443 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 549 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Consolidated Auxin Solar wattage variants sharing the Auxin Solar AXNG1M395B mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXNG1M390B | 390.0 W | 363.6 W | 47.9 V | 40.07 V | 19.9% |
| Auxin Solar AXNG1M395B | 395.0 W | 368.4 W | 48.33 V | 41.13 V | 20.15% |
How Many Auxin Solar AXNG1M395B Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Auxin Solar AXNG1M395B (52.69 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.94 V | 11 panels | 593.3 V | 18 panels |
| -10 C (14 F) | 52.69 V | 11 panels | 579.6 V | 18 panels |
| 0 C (32 F) | 51.45 V | 11 panels | 566.0 V | 19 panels |
| 25 C (77 F STC) | 48.33 V | 12 panels | 580.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXNG1M395B?
Competing CEC solar panels closest to Auxin Solar AXNG1M395B in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF23-395W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF23-395W {Blk} Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 48.37 V | 19.63% | 90.7% |
| Aptos Solar Technology LLC DNA-144-MF23-395W {Wht} Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 48.37 V | 20.26% | 93.4% |
| CertainTeed CT395HC00-04 CertainTeed |
395.0 W | Tie (0 W) | 48.37 V | 20.26% | 93.4% |
| CertainTeed CT395HC11-04 CertainTeed |
395.0 W | Tie (0 W) | 48.37 V | 20.26% | 90.8% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXNG1M395B?
Evaluate Auxin Solar AXNG1M395B (395.0 W STC, 48.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXNG1M395B reaches 53.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXNG1M395B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXNG1M395B 8 kW Residential Fit
Needs 21 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF23-395W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXNG1M395B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Auxin Solar AXNG1M395B?
Multiplying Auxin Solar AXNG1M395B's 10.24 A short-circuit current by 1.56 equals 15.97 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Auxin Solar AXNG1M395B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.69 V cold Voc at 14 F and handles 10.24 A Isc; string inverters cap Auxin Solar AXNG1M395B at 11 panels on 600 V.
Is Auxin Solar AXNG1M395B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXNG1M395B rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)