Mitrex M395-L3H is a 395.0 W STC (371.7 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.47% efficiency, 36.78 V Voc at 25 C, and 40.06 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 371.7 W
- Voc @ 25C
- 36.78 V
- Efficiency
- 20.47%
How Does Mitrex M395-L3H Compare Against Peer CEC Listings?
Engineering position of Mitrex M395-L3H (395.0 W STC) vs. ASTORIOS Holding Inc ASTR108BDG-395W-US across 5,889 CEC Mono-c-Si solar modules.
Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), Mitrex M395-L3H operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 36.78 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), 21 panels occupy 436 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Mitrex M395-L3H Fall Across Listed CEC Models?
Plots Mitrex M395-L3H at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Mitrex M395-L3H?
Benchmarks Mitrex M395-L3H on STC wattage, thermal PTC/STC retention, and 20.47 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Mitrex M395-L3H?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitrex M395-L3H by Mitrex.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.47% Aperture Efficiency
Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.06 V at -10 C (560.8 V string) and 41.0 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.5 m2 (436 sq ft) producing 7,806 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.78 * (1 + (-0.255/100) * (-10 - 25)) = 40.06 V | OCPD = 1.56 * 13.69 = 21.36 A
Inputs from CEC Modules.csv for Mitrex M395-L3H: Voc=36.78 V, beta_Voc=-0.255%/C, Isc=13.69 A, STC=395.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (560.8 V); 21 panels for 8 kW (436 sq ft).
What Are the Published CEC Specifications for Mitrex M395-L3H?
Laboratory test ratings recorded for Mitrex M395-L3H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 371.7 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.3 V / 13.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.255 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.47% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Mitrex M395-L3H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (436 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitrex M395-L3H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 332 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 436 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 540 sq ft | $2,570 | $4,347 |
How Many Mitrex M395-L3H Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Mitrex M395-L3H (beta_Voc -0.255%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.0 V | 14 panels | 574.0 V | 24 panels |
| -10 C (14 F) | 40.06 V | 14 panels | 560.8 V | 24 panels |
| 0 C (32 F) | 39.12 V | 15 panels | 586.8 V | 25 panels |
| 25 C (77 F STC) | 36.78 V | 16 panels | 588.5 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M395-L3H?
Closest cross-brand CEC competitors to Mitrex M395-L3H matched near 395.0 W STC and 36.78 V Voc, led by ASTORIOS Holding Inc ASTR108BDG-395W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR108BDG-395W-US ASTORIOS Holding Inc |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |
| AXITEC AC-395MBT/108V AXITEC |
395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| Belinus Solar BV BE-M7-GG-108-395 Belinus Solar BV |
395.0 W | Tie (0 W) | 37.03 V | 20.26% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Mitrex M395-L3H?
Evaluate Mitrex M395-L3H (395.0 W STC, 36.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M395-L3H reaches 41.0 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 436 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (436 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mitrex M395-L3H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M395-L3H 8 kW Residential Fit
Needs 21 modules (436 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-395W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 371.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M395-L3H by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
How many Mitrex M395-L3H panels fit on a 600 V winter solar string?
At -10 C (14 F), Mitrex M395-L3H cold Voc rises from 36.78 V to 40.06 V (beta_Voc -0.255%/C), capping a 600 V string at 14 panels (560.8 V).
How much roof area does an 8 kW array of Mitrex M395-L3H need?
An 8 kW DC system uses 21 Mitrex M395-L3H modules (8,295 W STC / 7,806 W PTC), covering roughly 436 sq ft and saving ~$2,075/yr at 18.54 c/kWh.
How does Mitrex M395-L3H compare against ASTORIOS Holding Inc ASTR108BDG-395W-US?
Mitrex M395-L3H outputs 395.0 W STC (36.78 V Voc, rank #9,869 of 21,677), while ASTORIOS Holding Inc ASTR108BDG-395W-US delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)