Belinus Solar BV BE-M7-GG-108-395 — CEC Solar Module Specifications

Manufacturer: Belinus Solar BV Registry: CEC Verified Engineering Specification

Belinus Solar BV BE-M7-GG-108-395 is a 395.0 W STC (370.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 37.03 V Voc at 25 C, and 40.36 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
370.4 W
Voc @ 25C
37.03 V
Efficiency
20.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Belinus Solar BV BE-M7-GG-108-395 Compare Against Peer CEC Listings?

How Belinus Solar BV Belinus Solar BV BE-M7-GG-108-395 handles rooftop heat (370.4 W PTC), 8 kW sizing, and cold winter string voltage.

Belinus Solar BV builds the Belinus Solar BV BE-M7-GG-108-395 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 (395.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Lower 37.03 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.2 A overcurrent floor served by a 25 A breaker.

Where Does Belinus Solar BV BE-M7-GG-108-395 Fall Across Listed CEC Models?

Where Belinus Solar BV BE-M7-GG-108-395 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Belinus Solar BV BE-M7-GG-108-395 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCBelinus Solar BV B: 395.0 W

What Dataset Percentiles Define Belinus Solar BV BE-M7-GG-108-395?

Percentile placement of Belinus Solar BV BE-M7-GG-108-395 across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.

Belinus Solar BV BE-M7-GG-108-395 Engineering BenchmarksPercentile comparison of Belinus Solar BV BE-M7-GG-108-395 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.8%Module Efficiency20.26%

What Do the Dataset Ranks Show for Belinus Solar BV BE-M7-GG-108-395?

Four critical engineering numbers homeowners and solar installers check first when reviewing Belinus Solar BV BE-M7-GG-108-395 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.36 V at -10 C (565.0 V string) and 41.31 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,778 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.03 * (1 + (-0.257/100) * (-10 - 25)) = 40.36 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for Belinus Solar BV BE-M7-GG-108-395: Voc=37.03 V, beta_Voc=-0.257%/C, Isc=13.59 A, STC=395.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (565.0 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for Belinus Solar BV BE-M7-GG-108-395?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Belinus Solar BV BE-M7-GG-108-395.

Official California Energy Commission (NREL SAM) test parameters for Belinus Solar BV BE-M7-GG-108-395.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 370.4 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.03 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.0 V / 12.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.26% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Belinus Solar BV BE-M7-GG-108-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Belinus Solar BV BE-M7-GG-108-395 (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 336 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 441 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 546 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This Belinus Solar BV Series?

All closely matched Belinus Solar BV wattages and cosmetic trims sharing the Belinus Solar BV BE-M7-GG-108-395 architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Belinus Solar BV BE-M7-GG-108-395 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Belinus Solar BV BE-M7-GG-108-390 390.0 W 365.6 W 36.84 V 30.82 V 20.0%
Belinus Solar BV BE-M7-GG-108-395 395.0 W 370.4 W 37.03 V 31.0 V 20.26%

How Many Belinus Solar BV BE-M7-GG-108-395 Modules Fit in a Cold-Weather String?

Maximum series module counts for Belinus Solar BV BE-M7-GG-108-395 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.03V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.31 V 14 panels 578.3 V 24 panels
-10 C (14 F) 40.36 V 14 panels 565.0 V 24 panels
0 C (32 F) 39.41 V 15 panels 591.1 V 25 panels
25 C (77 F STC) 37.03 V 16 panels 592.5 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Belinus Solar BV BE-M7-GG-108-395?

Alternative CEC solar modules from competing brands near Belinus Solar BV BE-M7-GG-108-395 (395.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-BF-395.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM54M-HC-BF-395
Elin Energy (Sirius PV)
395.0 W Tie (0 W) 37.02 V 20.36% 94.3%
AXITEC AC-395MBT/108V
AXITEC
395.0 W Tie (0 W) 37.0 V 20.47% 93.3%
ASTORIOS Holding Inc ASTR108BDG-395W-US
ASTORIOS Holding Inc
395.0 W Tie (0 W) 36.9 V 20.36% 92.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
390.0 W -5.0 W 36.9 V 20.21% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Belinus Solar BV BE-M7-GG-108-395?

Evaluate Belinus Solar BV BE-M7-GG-108-395 (395.0 W STC, 37.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Belinus Solar BV BE-M7-GG-108-395 reaches 41.31 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Belinus Solar BV BE-M7-GG-108-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Belinus Solar BV BE-M7-GG-108-395 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-395.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 370.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Belinus Solar BV BE-M7-GG-108-395 by Belinus Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Belinus Solar BV BE-M7-GG-108-395?

Multiplying Belinus Solar BV BE-M7-GG-108-395's 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Belinus Solar BV BE-M7-GG-108-395 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.36 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap Belinus Solar BV BE-M7-GG-108-395 at 14 panels on 600 V.

Is Belinus Solar BV BE-M7-GG-108-395 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Belinus Solar BV BE-M7-GG-108-395 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.