Mitrex M390-A1F is a 390.0 W STC (359.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.5% efficiency, 48.2 V Voc at 25 C, and 52.7 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 359.4 W
- Voc @ 25C
- 48.2 V
- Efficiency
- 19.5%
How Does Mitrex M390-A1F Compare Against Peer CEC Listings?
Engineering position of Mitrex M390-A1F (390.0 W STC) vs. CSI Solar Co Ltd CS3U-390MS across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Mitrex M390-A1F pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 48.2 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,547 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-390MS offers a 390.0 W alternative.
Where Does Mitrex M390-A1F Fall Across Listed CEC Models?
Plots Mitrex M390-A1F at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Mitrex M390-A1F?
Benchmarks Mitrex M390-A1F on STC wattage, thermal PTC/STC retention, and 19.5 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Mitrex M390-A1F?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitrex M390-A1F by Mitrex.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.5% Aperture Efficiency
Power density 195.0 W/m2 (0.41 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.7 V at -10 C (579.7 V string) and 53.99 V at -20 C (11 max).
21 Panels = 8,190 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,547 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.2 * (1 + (-0.267/100) * (-10 - 25)) = 52.7 V | OCPD = 1.56 * 9.77 = 15.24 A
Inputs from CEC Modules.csv for Mitrex M390-A1F: Voc=48.2 V, beta_Voc=-0.267%/C, Isc=9.77 A, STC=390.0 W, Area=2.0 m2.
Result: 11 panels max on 600 V (579.7 V); 21 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for Mitrex M390-A1F?
Laboratory test ratings recorded for Mitrex M390-A1F (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 359.4 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.9 V / 9.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.5% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Mitrex M390-A1F Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (452 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitrex M390-A1F.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 344 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 452 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 560 sq ft | $2,538 | $4,292 |
How Many Mitrex M390-A1F Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Mitrex M390-A1F (beta_Voc -0.267%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.99 V | 11 panels | 593.9 V | 18 panels |
| -10 C (14 F) | 52.7 V | 11 panels | 579.7 V | 18 panels |
| 0 C (32 F) | 51.42 V | 11 panels | 565.6 V | 19 panels |
| 25 C (77 F STC) | 48.2 V | 12 panels | 578.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M390-A1F?
Closest cross-brand CEC competitors to Mitrex M390-A1F matched near 390.0 W STC and 48.2 V Voc, led by CSI Solar Co Ltd CS3U-390MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-390MS CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| Auxin Solar AXNG1M395B Auxin Solar |
395.0 W | +5.0 W | 48.33 V | 20.15% | 93.3% |
| Auxin Solar AXNG1M395W Auxin Solar |
395.0 W | +5.0 W | 48.33 V | 20.15% | 93.2% |
| CSI Solar Co Ltd CS3W-390P CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 46.8 V | 18.22% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Mitrex M390-A1F?
Evaluate Mitrex M390-A1F (390.0 W STC, 48.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M390-A1F reaches 53.99 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Mitrex M390-A1F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M390-A1F 8 kW Residential Fit
Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M390-A1F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What fuse or breaker size does NEC 690.8 require for Mitrex M390-A1F?
Multiplying Mitrex M390-A1F's 9.77 A short-circuit current by 1.56 equals 15.24 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M390-A1F before finalizing component orders.
Can Mitrex M390-A1F pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.7 V cold Voc at 14 F and handles 9.77 A Isc; string inverters cap Mitrex M390-A1F at 11 panels on 600 V.
Is Mitrex M390-A1F eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M390-A1F rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)