Manufacturer: Mitrex Registry: CEC Verified Engineering Specification

Mitrex M390-A1F is a 390.0 W STC (359.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.5% efficiency, 48.2 V Voc at 25 C, and 52.7 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
359.4 W
Voc @ 25C
48.2 V
Efficiency
19.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitrex M390-A1F Compare Against Peer CEC Listings?

Engineering position of Mitrex M390-A1F (390.0 W STC) vs. CSI Solar Co Ltd CS3U-390MS across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Mitrex M390-A1F pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 48.2 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,547 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-390MS offers a 390.0 W alternative.

Where Does Mitrex M390-A1F Fall Across Listed CEC Models?

Plots Mitrex M390-A1F at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitrex M390-A1F (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitrex M390-A1F: 390.0 W

What Dataset Percentiles Define Mitrex M390-A1F?

Benchmarks Mitrex M390-A1F on STC wattage, thermal PTC/STC retention, and 19.5 aperture conversion efficiency against CEC peers.

Mitrex M390-A1F Engineering BenchmarksPercentile comparison of Mitrex M390-A1F wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention92.2%Module Efficiency19.5%

What Do the Dataset Ranks Show for Mitrex M390-A1F?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitrex M390-A1F by Mitrex.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,199

19.5% Aperture Efficiency

Power density 195.0 W/m2 (0.41 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.7 V at -10 C (579.7 V string) and 53.99 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,547 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.2 * (1 + (-0.267/100) * (-10 - 25)) = 52.7 V | OCPD = 1.56 * 9.77 = 15.24 A

Inputs from CEC Modules.csv for Mitrex M390-A1F: Voc=48.2 V, beta_Voc=-0.267%/C, Isc=9.77 A, STC=390.0 W, Area=2.0 m2.

Result: 11 panels max on 600 V (579.7 V); 21 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for Mitrex M390-A1F?

Laboratory test ratings recorded for Mitrex M390-A1F (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mitrex M390-A1F.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 359.4 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.9 V / 9.31 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.5% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Mitrex M390-A1F Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (452 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitrex M390-A1F.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 344 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 452 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 560 sq ft $2,538 $4,292

How Many Mitrex M390-A1F Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mitrex M390-A1F (beta_Voc -0.267%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.2V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.99 V 11 panels 593.9 V 18 panels
-10 C (14 F) 52.7 V 11 panels 579.7 V 18 panels
0 C (32 F) 51.42 V 11 panels 565.6 V 19 panels
25 C (77 F STC) 48.2 V 12 panels 578.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Mitrex M390-A1F?

Closest cross-brand CEC competitors to Mitrex M390-A1F matched near 390.0 W STC and 48.2 V Voc, led by CSI Solar Co Ltd CS3U-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 48.2 V 20.31% 93.2%
Auxin Solar AXNG1M395B
Auxin Solar
395.0 W +5.0 W 48.33 V 20.15% 93.3%
Auxin Solar AXNG1M395W
Auxin Solar
395.0 W +5.0 W 48.33 V 20.15% 93.2%
CSI Solar Co Ltd CS3W-390P
CSI Solar Co Ltd
390.0 W Tie (0 W) 46.8 V 18.22% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitrex M390-A1F?

Evaluate Mitrex M390-A1F (390.0 W STC, 48.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitrex M390-A1F reaches 53.99 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Mitrex M390-A1F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitrex M390-A1F 8 kW Residential Fit

Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitrex M390-A1F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What fuse or breaker size does NEC 690.8 require for Mitrex M390-A1F?

Multiplying Mitrex M390-A1F's 9.77 A short-circuit current by 1.56 equals 15.24 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M390-A1F before finalizing component orders.

Can Mitrex M390-A1F pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.7 V cold Voc at 14 F and handles 9.77 A Isc; string inverters cap Mitrex M390-A1F at 11 panels on 600 V.

Is Mitrex M390-A1F eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M390-A1F rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.