Mitrex M295-RF041F is a 295.0 W STC (267.9 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 14.75% efficiency, 48.4 V Voc at 25 C, and 53.02 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
267.9 W
Voc @ 25C
48.4 V
Efficiency
14.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitrex M295-RF041F Compare Against Peer CEC Listings?

Solar engineering breakdown for Mitrex M295-RF041F: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Measured at 295.0 W STC and 267.9 W PTC, Mitrex M295-RF041F sits -90.0 W vs all-CEC median (below all-CEC median; higher than 20.4% of peers) among 21,677 listed modules. Power density reaches 147.5 W/m2 (5.16 percentage points below 19.91% CEC median). Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Centrosolar America TP7 295xx rates 295.0 W.

Where Does Mitrex M295-RF041F Fall Across Listed CEC Models?

Distribution marker showing Mitrex M295-RF041F (295.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitrex M295-RF041F (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitrex M295-RF041F: 295.0 W

What Dataset Percentiles Define Mitrex M295-RF041F?

Dataset percentiles tracking Mitrex M295-RF041F power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Mitrex M295-RF041F Engineering BenchmarksPercentile comparison of Mitrex M295-RF041F wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention90.8%Module Efficiency14.75%

What Do the Dataset Ranks Show for Mitrex M295-RF041F?

Benchmark highlights for Mitrex M295-RF041F covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,070

14.75% Aperture Efficiency

Power density 147.5 W/m2 (5.16 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.02 V at -10 C (583.2 V string) and 54.35 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 56.0 m2 (603 sq ft) producing 7,501 W PTC; NEC 690.8 OCPD floor is 11.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.4 * (1 + (-0.273/100) * (-10 - 25)) = 53.02 V | OCPD = 1.56 * 7.64 = 11.92 A

Inputs from CEC Modules.csv for Mitrex M295-RF041F: Voc=48.4 V, beta_Voc=-0.273%/C, Isc=7.64 A, STC=295.0 W, Area=2.0 m2.

Result: 11 panels max on 600 V (583.2 V); 28 panels for 8 kW (603 sq ft).

What Are the Published CEC Specifications for Mitrex M295-RF041F?

Official CEC datasheet figures for Mitrex M295-RF041F (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Mitrex M295-RF041F.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 267.9 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.5 V / 7.28 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.273 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.75% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Mitrex M295-RF041F Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mitrex M295-RF041F modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 452 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 603 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 732 sq ft $2,510 $4,245

How Many Mitrex M295-RF041F Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mitrex M295-RF041F (53.02 V at 14 F). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Computed from Voc=48.4V and beta_Voc=-0.273%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.35 V 11 panels 597.9 V 18 panels
-10 C (14 F) 53.02 V 11 panels 583.2 V 18 panels
0 C (32 F) 51.7 V 11 panels 568.7 V 19 panels
25 C (77 F STC) 48.4 V 12 panels 580.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Mitrex M295-RF041F?

Competing CEC solar panels closest to Mitrex M295-RF041F in nameplate wattage and Voc, starting with Centrosolar America TP7 295xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TP7 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
Centrosolar America TP7S 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W Tie (0 W) 44.9 V 15.21% 91.5%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W Tie (0 W) 44.4 V 15.28% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitrex M295-RF041F?

Evaluate Mitrex M295-RF041F (295.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitrex M295-RF041F reaches 54.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 603 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (603 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitrex M295-RF041F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitrex M295-RF041F 8 kW Residential Fit

Needs 28 modules (603 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America TP7 295xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 267.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitrex M295-RF041F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many Mitrex M295-RF041F panels fit on a 600 V winter solar string?

At -10 C (14 F), Mitrex M295-RF041F cold Voc rises from 48.4 V to 53.02 V (beta_Voc -0.273%/C), capping a 600 V string at 11 panels (583.2 V).

How much roof area does an 8 kW array of Mitrex M295-RF041F need?

An 8 kW DC system uses 28 Mitrex M295-RF041F modules (8,260 W STC / 7,501 W PTC), covering roughly 603 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does Mitrex M295-RF041F compare against Centrosolar America TP7 295xx?

Mitrex M295-RF041F outputs 295.0 W STC (48.4 V Voc, rank #16,890 of 21,677), while Centrosolar America TP7 295xx delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.