Manufacturer: Merlin Solar Technologies Inc Registry: CEC Verified Engineering Specification

Merlin Solar Technologies Inc FXS 155L-W is a 155.0 W STC (142.0 W PTC) Mono-c-Si solar module ranking #21,394 of 21,677 CEC listings (below all-CEC median; higher than 1.2% of peers). It delivers 13.96% efficiency, 23.01 V Voc at 25 C, and 25.48 V cold Voc at -10 C (23 panels max per 600 V string).

STC Wattage
155.0 W
PTC Wattage
142.0 W
Voc @ 25C
23.01 V
Efficiency
13.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Merlin Solar Technologies Inc FXS 155L-W Compare Against Peer CEC Listings?

Solar engineering breakdown for Merlin Solar Technologies Inc FXS 155L-W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 155.0 W STC and 142.0 W PTC, Merlin Solar Technologies Inc FXS 155L-W sits -230.0 W vs all-CEC median (below all-CEC median; higher than 1.2% of peers) among 21,677 listed modules. Power density reaches 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). Lower 23.01 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 39 panels in series. Alternative peer Auxin Solar AXN6M409T155 rates 155.0 W.

Where Does Merlin Solar Technologies Inc FXS 155L-W Fall Across Listed CEC Models?

Distribution marker showing Merlin Solar Technologies Inc FXS 155L-W (155.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Merlin Solar Technologies Inc FXS 155L-W (155.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMerlin Solar Techn: 155.0 W

What Dataset Percentiles Define Merlin Solar Technologies Inc FXS 155L-W?

Dataset percentiles tracking Merlin Solar Technologies Inc FXS 155L-W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Merlin Solar Technologies Inc FXS 155L-W Engineering BenchmarksPercentile comparison of Merlin Solar Technologies Inc FXS 155L-W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage155.0 WPTC/STC Retention91.6%Module Efficiency13.96%

What Do the Dataset Ranks Show for Merlin Solar Technologies Inc FXS 155L-W?

Benchmark highlights for Merlin Solar Technologies Inc FXS 155L-W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,394 / 21,677

155.0 W STC · Higher Than 1.2%

155.0 W STC (-230.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,928

13.96% Aperture Efficiency

Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

23 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.48 V at -10 C (586.0 V string) and 26.19 V at -20 C (22 max).

8 kW Reference Array

52 Panels = 8,060 W STC

Occupies 57.7 m2 (621 sq ft) producing 7,384 W PTC; NEC 690.8 OCPD floor is 13.6 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 23.01 * (1 + (-0.307/100) * (-10 - 25)) = 25.48 V | OCPD = 1.56 * 8.72 = 13.6 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc FXS 155L-W: Voc=23.01 V, beta_Voc=-0.307%/C, Isc=8.72 A, STC=155.0 W, Area=1.11 m2.

Result: 23 panels max on 600 V (586.0 V); 52 panels for 8 kW (621 sq ft).

What Are the Published CEC Specifications for Merlin Solar Technologies Inc FXS 155L-W?

Official CEC datasheet figures for Merlin Solar Technologies Inc FXS 155L-W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc FXS 155L-W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 155.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 142.0 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 23.01 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 18.35 V / 8.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.96% (1.11 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Merlin Solar Technologies Inc FXS 155L-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Merlin Solar Technologies Inc FXS 155L-W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 39 6.04 kW 466 sq ft $1,512 $2,556
8 kW Class 52 8.06 kW 621 sq ft $2,017 $3,411
10 kW Class 65 10.07 kW 777 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

Consolidated Merlin Solar Technologies Inc wattage variants sharing the Merlin Solar Technologies Inc FXS 155L-W mechanical and cell layout.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc FXS 155L-W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Merlin Solar Technologies Inc FXS 150L-W 150.0 W 137.3 W 22.67 V 18.02 V 13.51%
Merlin Solar Technologies Inc FXS 155L-W 155.0 W 142.0 W 23.01 V 18.35 V 13.96%
Merlin Solar Technologies Inc FXS 160L-W 160.0 W 146.7 W 23.25 V 18.75 V 14.41%

How Many Merlin Solar Technologies Inc FXS 155L-W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Merlin Solar Technologies Inc FXS 155L-W (25.48 V at 14 F).

Computed from Voc=23.01V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 26.19 V 22 panels 576.2 V 38 panels
-10 C (14 F) 25.48 V 23 panels 586.0 V 39 panels
0 C (32 F) 24.78 V 24 panels 594.7 V 40 panels
25 C (77 F STC) 23.01 V 26 panels 598.3 V 43 panels

Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc FXS 155L-W?

Competing CEC solar panels closest to Merlin Solar Technologies Inc FXS 155L-W in nameplate wattage and Voc, starting with Auxin Solar AXN6M409T155.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M409T155
Auxin Solar
155.0 W Tie (0 W) 22.68 V 15.82% 89.5%
Gintung Energy ASEC-155G6S49
Gintung Energy
155.0 W Tie (0 W) 22.58 V 15.71% 87.7%
Gintung Energy ASEC-155G6M49
Gintung Energy
155.0 W Tie (0 W) 22.53 V 15.71% 88.1%
Centrosolar America DP36 150
Centrosolar America
150.0 W -5.0 W 22.51 V 14.84% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc FXS 155L-W?

Evaluate Merlin Solar Technologies Inc FXS 155L-W (155.0 W STC, 23.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc FXS 155L-W reaches 26.19 V per panel—exceeding 22 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 52 panels for an 8 kW build require 621 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 52 panels (621 sq ft).
  • 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc FXS 155L-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Merlin Solar Technologies Inc FXS 155L-W 8 kW Residential Fit

Needs 52 modules (621 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 23 panels (-10 C) or 22 panels (-20 C), or compare Auxin Solar AXN6M409T155.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 142.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc FXS 155L-W by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Merlin Solar Technologies Inc FXS 155L-W panels fit on a 600 V winter solar string?

At -10 C (14 F), Merlin Solar Technologies Inc FXS 155L-W cold Voc rises from 23.01 V to 25.48 V (beta_Voc -0.307%/C), capping a 600 V string at 23 panels (586.0 V).

How much roof area does an 8 kW array of Merlin Solar Technologies Inc FXS 155L-W need?

An 8 kW DC system uses 52 Merlin Solar Technologies Inc FXS 155L-W modules (8,060 W STC / 7,384 W PTC), covering roughly 621 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Merlin Solar Technologies Inc FXS 155L-W compare against Auxin Solar AXN6M409T155?

Merlin Solar Technologies Inc FXS 155L-W outputs 155.0 W STC (23.01 V Voc, rank #21,394 of 21,677), while Auxin Solar AXN6M409T155 delivers 155.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.