Centrosolar America DP36 150 is a 150.0 W STC (132.8 W PTC) Multi-c-Si solar module ranking #21,410 of 21,677 CEC listings (below all-CEC median; higher than 1.2% of peers). It delivers 14.84% efficiency, 22.51 V Voc at 25 C, and 25.35 V cold Voc at -10 C (23 panels max per 600 V string).
- STC Wattage
- 150.0 W
- PTC Wattage
- 132.8 W
- Voc @ 25C
- 22.51 V
- Efficiency
- 14.84%
How Does Centrosolar America DP36 150 Compare Against Peer CEC Listings?
Engineering position of Centrosolar America DP36 150 (150.0 W STC) vs. Solartech Energy ASC-6P-36-150 across 1,407 CEC Multi-c-Si solar modules.
Ranking #21,410 across 21,677 CEC solar panels (below all-CEC median; higher than 1.2% of peers), Centrosolar America DP36 150 operates as a compact residential or specialty off-grid module sitting 128.8 W below the 278.8 W Multi-c-Si median. Lower 22.51 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters. With typical 88.5% PTC-to-STC thermal output (132.8 W real-world rating), 54 panels occupy 588 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Centrosolar America DP36 150 Fall Across Listed CEC Models?
Plots Centrosolar America DP36 150 at 150.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Centrosolar America DP36 150?
Benchmarks Centrosolar America DP36 150 on STC wattage, thermal PTC/STC retention, and 14.84 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Centrosolar America DP36 150?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America DP36 150 by Centrosolar America.
150.0 W STC · Higher Than 1.2%
150.0 W STC (-235.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.84% Aperture Efficiency
Power density 148.4 W/m2 (5.07 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).
23 Panels Max @ -10 C (600 V)
Cold Voc reaches 25.35 V at -10 C (583.1 V string) and 26.16 V at -20 C (22 max).
54 Panels = 8,100 W STC
Occupies 54.6 m2 (588 sq ft) producing 7,171 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.51 * (1 + (-0.36/100) * (-10 - 25)) = 25.35 V | OCPD = 1.56 * 8.63 = 13.46 A
Inputs from CEC Modules.csv for Centrosolar America DP36 150: Voc=22.51 V, beta_Voc=-0.36%/C, Isc=8.63 A, STC=150.0 W, Area=1.011 m2.
Result: 23 panels max on 600 V (583.1 V); 54 panels for 8 kW (588 sq ft).
What Are the Published CEC Specifications for Centrosolar America DP36 150?
Laboratory test ratings recorded for Centrosolar America DP36 150 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 150.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 132.8 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.51 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 18.45 V / 8.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.84% (1.011 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America DP36 150 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (588 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America DP36 150.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 40 | 6.0 kW | 435 sq ft | $1,502 | $2,539 |
| 8 kW Class | 54 | 8.1 kW | 588 sq ft | $2,027 | $3,428 |
| 10 kW Class | 67 | 10.05 kW | 729 sq ft | $2,515 | $4,253 |
How Many Centrosolar America DP36 150 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Centrosolar America DP36 150 (beta_Voc -0.36%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 26.16 V | 22 panels | 575.5 V | 38 panels |
| -10 C (14 F) | 25.35 V | 23 panels | 583.1 V | 39 panels |
| 0 C (32 F) | 24.54 V | 24 panels | 589.0 V | 40 panels |
| 25 C (77 F STC) | 22.51 V | 26 panels | 585.3 V | 44 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP36 150?
Closest cross-brand CEC competitors to Centrosolar America DP36 150 matched near 150.0 W STC and 22.51 V Voc, led by Solartech Energy ASC-6P-36-150.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Solartech Energy ASC-6P-36-150 Solartech Energy |
150.0 W | Tie (0 W) | 22.51 V | 14.84% | 88.5% |
| US Solar USS-QCMI2-36-150 US Solar |
150.0 W | Tie (0 W) | 22.51 V | 14.84% | 88.5% |
| Gintung Energy ASEC-155G6M49 Gintung Energy |
155.0 W | +5.0 W | 22.53 V | 15.71% | 88.1% |
| Gintung Energy ASEC-155G6S49 Gintung Energy |
155.0 W | +5.0 W | 22.58 V | 15.71% | 87.7% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America DP36 150?
Evaluate Centrosolar America DP36 150 (150.0 W STC, 22.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP36 150 reaches 26.16 V per panel—exceeding 22 panels in series voids 600 V inverter warranties.
- Footprint constraint: 54 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 54 panels (588 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP36 150 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America DP36 150 8 kW Residential Fit
Needs 54 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 23 panels (-10 C) or 22 panels (-20 C), or compare Solartech Energy ASC-6P-36-150.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 132.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America DP36 150 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Centrosolar America DP36 150 panels fit on a 600 V winter solar string?
At -10 C (14 F), Centrosolar America DP36 150 cold Voc rises from 22.51 V to 25.35 V (beta_Voc -0.36%/C), capping a 600 V string at 23 panels (583.1 V).
How much roof area does an 8 kW array of Centrosolar America DP36 150 need?
An 8 kW DC system uses 54 Centrosolar America DP36 150 modules (8,100 W STC / 7,171 W PTC), covering roughly 588 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Centrosolar America DP36 150 compare against Solartech Energy ASC-6P-36-150?
Centrosolar America DP36 150 outputs 150.0 W STC (22.51 V Voc, rank #21,410 of 21,677), while Solartech Energy ASC-6P-36-150 delivers 150.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)