Gintung Energy ASEC-155G6M49 is a 155.0 W STC (136.5 W PTC) Multi-c-Si solar module ranking #21,394 of 21,677 CEC listings (below all-CEC median; higher than 1.2% of peers). It delivers 15.71% efficiency, 22.53 V Voc at 25 C, and 25.23 V cold Voc at -10 C (23 panels max per 600 V string).
- STC Wattage
- 155.0 W
- PTC Wattage
- 136.5 W
- Voc @ 25C
- 22.53 V
- Efficiency
- 15.71%
How Does Gintung Energy ASEC-155G6M49 Compare Against Peer CEC Listings?
Solar engineering breakdown for Gintung Energy ASEC-155G6M49: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Measured at 155.0 W STC and 136.5 W PTC, Gintung Energy ASEC-155G6M49 sits -230.0 W vs all-CEC median (below all-CEC median; higher than 1.2% of peers) among 21,677 listed modules. Power density reaches 157.2 W/m2 (4.20 percentage points below 19.91% CEC median). Lower 22.53 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 39 panels in series. Alternative peer Auxin Solar AXN6M409T155 rates 155.0 W.
Where Does Gintung Energy ASEC-155G6M49 Fall Across Listed CEC Models?
Distribution marker showing Gintung Energy ASEC-155G6M49 (155.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Gintung Energy ASEC-155G6M49?
Dataset percentiles tracking Gintung Energy ASEC-155G6M49 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Gintung Energy ASEC-155G6M49?
Benchmark highlights for Gintung Energy ASEC-155G6M49 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
155.0 W STC · Higher Than 1.2%
155.0 W STC (-230.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.71% Aperture Efficiency
Power density 157.2 W/m2 (4.20 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).
23 Panels Max @ -10 C (600 V)
Cold Voc reaches 25.23 V at -10 C (580.3 V string) and 26.01 V at -20 C (23 max).
52 Panels = 8,060 W STC
Occupies 51.3 m2 (552 sq ft) producing 7,098 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.53 * (1 + (-0.343/100) * (-10 - 25)) = 25.23 V | OCPD = 1.56 * 8.98 = 14.01 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-155G6M49: Voc=22.53 V, beta_Voc=-0.343%/C, Isc=8.98 A, STC=155.0 W, Area=0.986 m2.
Result: 23 panels max on 600 V (580.3 V); 52 panels for 8 kW (552 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-155G6M49?
Official CEC datasheet figures for Gintung Energy ASEC-155G6M49 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 155.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 136.5 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 18.07 V / 8.58 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.71% (0.986 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-155G6M49 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gintung Energy ASEC-155G6M49 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 39 | 6.04 kW | 414 sq ft | $1,512 | $2,556 |
| 8 kW Class | 52 | 8.06 kW | 552 sq ft | $2,017 | $3,411 |
| 10 kW Class | 65 | 10.07 kW | 690 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Consolidated Gintung Energy wattage variants sharing the Gintung Energy ASEC-155G6M49 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy ASEC-150G6M49 | 150.0 W | 131.9 W | 22.4 V | 17.92 V | 15.21% |
| Gintung Energy ASEC-155G6M49 | 155.0 W | 136.5 W | 22.53 V | 18.07 V | 15.71% |
How Many Gintung Energy ASEC-155G6M49 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy ASEC-155G6M49 (25.23 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 26.01 V | 23 panels | 598.2 V | 38 panels |
| -10 C (14 F) | 25.23 V | 23 panels | 580.3 V | 39 panels |
| 0 C (32 F) | 24.46 V | 24 panels | 587.0 V | 40 panels |
| 25 C (77 F STC) | 22.53 V | 26 panels | 585.8 V | 44 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-155G6M49?
Competing CEC solar panels closest to Gintung Energy ASEC-155G6M49 in nameplate wattage and Voc, starting with Auxin Solar AXN6M409T155.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M409T155 Auxin Solar |
155.0 W | Tie (0 W) | 22.68 V | 15.82% | 89.5% |
| Merlin Solar Technologies Inc FX 155L-B Merlin Solar Technologies Inc |
155.0 W | Tie (0 W) | 23.01 V | 13.96% | 89.5% |
| Merlin Solar Technologies Inc FXS 155L-W Merlin Solar Technologies Inc |
155.0 W | Tie (0 W) | 23.01 V | 13.96% | 91.6% |
| Merlin Solar Technologies Inc FXS 155S-W Merlin Solar Technologies Inc |
155.0 W | Tie (0 W) | 23.01 V | 14.76% | 91.7% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-155G6M49?
Evaluate Gintung Energy ASEC-155G6M49 (155.0 W STC, 22.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-155G6M49 reaches 26.01 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 52 panels for an 8 kW build require 552 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 52 panels (552 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-155G6M49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-155G6M49 8 kW Residential Fit
Needs 52 modules (552 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 23 panels (-10 C) or 23 panels (-20 C), or compare Auxin Solar AXN6M409T155.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 136.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-155G6M49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy ASEC-155G6M49 panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy ASEC-155G6M49 cold Voc rises from 22.53 V to 25.23 V (beta_Voc -0.343%/C), capping a 600 V string at 23 panels (580.3 V).
How much roof area does an 8 kW array of Gintung Energy ASEC-155G6M49 need?
An 8 kW DC system uses 52 Gintung Energy ASEC-155G6M49 modules (8,060 W STC / 7,098 W PTC), covering roughly 552 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does Gintung Energy ASEC-155G6M49 compare against Auxin Solar AXN6M409T155?
Gintung Energy ASEC-155G6M49 outputs 155.0 W STC (22.53 V Voc, rank #21,394 of 21,677), while Auxin Solar AXN6M409T155 delivers 155.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)