Lumos L40-235-47-xx is a 235.0 W STC (216.7 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 10.31% efficiency, 27.3 V Voc at 25 C, and 30.4 V cold Voc at -10 C (19 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 216.7 W
- Voc @ 25C
- 27.3 V
- Efficiency
- 10.31%
How Does Lumos L40-235-47-xx Compare Against Peer CEC Listings?
How Lumos Lumos L40-235-47-xx handles rooftop heat (216.7 W PTC), 8 kW sizing, and cold winter string voltage.
Lumos builds the Lumos L40-235-47-xx (Mono-c-Si) as a compact residential or specialty off-grid module delivering 103.1 W/m2 (9.60 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-235G6M69 (235.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Lower 27.3 V string voltage fits 19 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 17.63 A overcurrent floor served by a 20 A breaker.
Where Does Lumos L40-235-47-xx Fall Across Listed CEC Models?
Where Lumos L40-235-47-xx (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Lumos L40-235-47-xx?
Percentile placement of Lumos L40-235-47-xx across power density (103.1 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Lumos L40-235-47-xx?
Four critical engineering numbers homeowners and solar installers check first when reviewing Lumos L40-235-47-xx specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
10.31% Aperture Efficiency
Power density 103.1 W/m2 (9.60 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
19 Panels Max @ -10 C (600 V)
Cold Voc reaches 30.4 V at -10 C (577.6 V string) and 31.28 V at -20 C (19 max).
35 Panels = 8,225 W STC
Occupies 79.8 m2 (859 sq ft) producing 7,584 W PTC; NEC 690.8 OCPD floor is 17.63 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 27.3 * (1 + (-0.324/100) * (-10 - 25)) = 30.4 V | OCPD = 1.56 * 11.3 = 17.63 A
Inputs from CEC Modules.csv for Lumos L40-235-47-xx: Voc=27.3 V, beta_Voc=-0.324%/C, Isc=11.3 A, STC=235.0 W, Area=2.28 m2.
Result: 19 panels max on 600 V (577.6 V); 35 panels for 8 kW (859 sq ft).
What Are the Published CEC Specifications for Lumos L40-235-47-xx?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lumos L40-235-47-xx. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 216.7 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 27.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 22.14 V / 10.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 10.31% (2.28 m2) | Array roof footprint density |
| Cell Count & Technology | 40 cells (Mono-c-Si) | Monofacial backsheet |
How Many Lumos L40-235-47-xx Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lumos L40-235-47-xx (235.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 638 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 859 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 1,055 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Lumos Series?
All closely matched Lumos wattages and cosmetic trims sharing the Lumos L40-235-47-xx architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Lumos L40-225-47-xx | 225.0 W | 207.4 W | 27.1 V | 21.94 V | 9.87% |
| Lumos L40-230-47-xx | 230.0 W | 212.1 W | 27.2 V | 22.04 V | 10.09% |
| Lumos L40-235-47-xx | 235.0 W | 216.7 W | 27.3 V | 22.14 V | 10.31% |
| Lumos L40-240-47-xx | 240.0 W | 221.4 W | 27.4 V | 22.25 V | 10.53% |
How Many Lumos L40-235-47-xx Modules Fit in a Cold-Weather String?
Maximum series module counts for Lumos L40-235-47-xx from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 31.28 V | 19 panels | 594.3 V | 31 panels |
| -10 C (14 F) | 30.4 V | 19 panels | 577.6 V | 32 panels |
| 0 C (32 F) | 29.51 V | 20 panels | 590.2 V | 33 panels |
| 25 C (77 F STC) | 27.3 V | 21 panels | 573.3 V | 36 panels |
Which Cross-Brand Solar Modules Compare Closest to Lumos L40-235-47-xx?
Alternative CEC solar modules from competing brands near Lumos L40-235-47-xx (235.0 W), including Gintung Energy ASEC-235G6M69. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-235G6M69 Gintung Energy |
235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| Gintung Energy GTEC-235G6M69 Gintung Energy |
235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| Gintung Energy ASEC-235G6S69 Gintung Energy |
235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |
| Gintung Energy GTEC-235G6S69 Gintung Energy |
235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |
What Are the Design Limits and Best-Fit Uses for Lumos L40-235-47-xx?
Evaluate Lumos L40-235-47-xx (235.0 W STC, 27.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lumos L40-235-47-xx reaches 31.28 V per panel—exceeding 19 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 859 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (859 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos L40-235-47-xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lumos L40-235-47-xx 8 kW Residential Fit
Needs 35 modules (859 sq ft) with a 20 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 19 panels (-10 C) or 19 panels (-20 C), or compare Gintung Energy ASEC-235G6M69.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 216.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lumos L40-235-47-xx by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for Lumos L40-235-47-xx?
Multiplying Lumos L40-235-47-xx's 11.3 A short-circuit current by 1.56 equals 17.63 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Lumos L40-235-47-xx before finalizing component orders.
Can Lumos L40-235-47-xx pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 30.4 V cold Voc at 14 F and handles 11.3 A Isc; string inverters cap Lumos L40-235-47-xx at 19 panels on 600 V.
Is Lumos L40-235-47-xx eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lumos L40-235-47-xx rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)