Lumos L72-415-08-xx is a 415.0 W STC (386.7 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 18.2% efficiency, 48.9 V Voc at 25 C, and 54.45 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 386.7 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 18.2%
How Does Lumos L72-415-08-xx Compare Against Peer CEC Listings?
Solar engineering breakdown for Lumos L72-415-08-xx: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Measured at 415.0 W STC and 386.7 W PTC, Lumos L72-415-08-xx sits +30.0 W vs all-CEC median (top 39.4%; higher than 60.6% of peers) among 21,677 listed modules. Power density reaches 182.0 W/m2 (1.71 percentage points below 19.91% CEC median). Higher 48.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Aptos Solar Technology LLC DNA-144-BF23-410W rates 410.0 W.
Where Does Lumos L72-415-08-xx Fall Across Listed CEC Models?
Distribution marker showing Lumos L72-415-08-xx (415.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Dataset Percentiles Define Lumos L72-415-08-xx?
Dataset percentiles tracking Lumos L72-415-08-xx power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Lumos L72-415-08-xx?
Benchmark highlights for Lumos L72-415-08-xx covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.2% Aperture Efficiency
Power density 182.0 W/m2 (1.71 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.45 V at -10 C (599.0 V string) and 56.03 V at -20 C (10 max).
20 Panels = 8,300 W STC
Occupies 45.6 m2 (491 sq ft) producing 7,734 W PTC; NEC 690.8 OCPD floor is 17.16 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.324/100) * (-10 - 25)) = 54.45 V | OCPD = 1.56 * 11.0 = 17.16 A
Inputs from CEC Modules.csv for Lumos L72-415-08-xx: Voc=48.9 V, beta_Voc=-0.324%/C, Isc=11.0 A, STC=415.0 W, Area=2.28 m2.
Result: 11 panels max on 600 V (599.0 V); 20 panels for 8 kW (491 sq ft).
What Are the Published CEC Specifications for Lumos L72-415-08-xx?
Official CEC datasheet figures for Lumos L72-415-08-xx (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 386.7 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.7 V / 10.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.2% (2.28 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Lumos L72-415-08-xx Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Lumos L72-415-08-xx modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 368 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 491 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 614 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This Lumos Series?
Consolidated Lumos wattage variants sharing the Lumos L72-415-08-xx mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Lumos L72-410-08-xx | 410.0 W | 382.0 W | 48.8 V | 39.6 V | 17.98% |
| Lumos L72-415-08-xx | 415.0 W | 386.7 W | 48.9 V | 39.7 V | 18.2% |
| Lumos L72-420-08-xx | 420.0 W | 391.5 W | 49.0 V | 39.8 V | 18.42% |
How Many Lumos L72-415-08-xx Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Lumos L72-415-08-xx (54.45 V at 14 F). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.03 V | 10 panels | 560.3 V | 17 panels |
| -10 C (14 F) | 54.45 V | 11 panels | 599.0 V | 18 panels |
| 0 C (32 F) | 52.86 V | 11 panels | 581.5 V | 18 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Lumos L72-415-08-xx?
Competing CEC solar panels closest to Lumos L72-415-08-xx in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-BF23-410W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-BF23-410W Aptos Solar Technology LLC |
410.0 W | -5.0 W | 48.56 V | 21.03% | 93.4% |
| CSI Solar Co Ltd CS3W-420MB-AG CSI Solar Co Ltd |
420.0 W | +5.0 W | 47.9 V | 19.44% | 92.7% |
| CSI Solar Co Ltd CS3W-410PB-AG CSI Solar Co Ltd |
410.0 W | -5.0 W | 47.6 V | 18.89% | 93.4% |
| CSI Solar Co Ltd CS3U-405MB-AG CSI Solar Co Ltd |
405.0 W | -10.0 W | 49.3 V | 20.56% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Lumos L72-415-08-xx?
Evaluate Lumos L72-415-08-xx (415.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lumos L72-415-08-xx reaches 56.03 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 491 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (491 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Lumos L72-415-08-xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lumos L72-415-08-xx 8 kW Residential Fit
Needs 20 modules (491 sq ft) with a 20 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF23-410W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 386.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lumos L72-415-08-xx by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
How many Lumos L72-415-08-xx panels fit on a 600 V winter solar string?
At -10 C (14 F), Lumos L72-415-08-xx cold Voc rises from 48.9 V to 54.45 V (beta_Voc -0.324%/C), capping a 600 V string at 11 panels (599.0 V).
How much roof area does an 8 kW array of Lumos L72-415-08-xx need?
An 8 kW DC system uses 20 Lumos L72-415-08-xx modules (8,300 W STC / 7,734 W PTC), covering roughly 491 sq ft and saving ~$2,077/yr at 18.54 c/kWh.
How does Lumos L72-415-08-xx compare against Aptos Solar Technology LLC DNA-144-BF23-410W?
Lumos L72-415-08-xx outputs 415.0 W STC (48.9 V Voc, rank #8,199 of 21,677), while Aptos Solar Technology LLC DNA-144-BF23-410W delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)