Manufacturer: Lumos Registry: CEC Verified Engineering Specification

Lumos S60-355-13-IM is a 355.0 W STC (330.9 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 18.39% efficiency, 41.0 V Voc at 25 C, and 45.65 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
355.0 W
PTC Wattage
330.9 W
Voc @ 25C
41.0 V
Efficiency
18.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lumos S60-355-13-IM Compare Against Peer CEC Listings?

Engineering position of Lumos S60-355-13-IM (355.0 W STC) vs. Aptos Solar Technology LLC DNA-120-BF26-365W across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Lumos S60-355-13-IM pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 41.0 V nominal Voc. An 8 kW residential build (8,165 W DC, 7,611 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Aptos Solar Technology LLC DNA-120-BF26-365W offers a 365.0 W alternative.

Where Does Lumos S60-355-13-IM Fall Across Listed CEC Models?

Plots Lumos S60-355-13-IM at 355.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lumos S60-355-13-IM (355.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLumos S60-355-13-I: 355.0 W

What Dataset Percentiles Define Lumos S60-355-13-IM?

Benchmarks Lumos S60-355-13-IM on STC wattage, thermal PTC/STC retention, and 18.39 aperture conversion efficiency against CEC peers.

Lumos S60-355-13-IM Engineering BenchmarksPercentile comparison of Lumos S60-355-13-IM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage355.0 WPTC/STC Retention93.2%Module Efficiency18.39%

What Do the Dataset Ranks Show for Lumos S60-355-13-IM?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Lumos S60-355-13-IM by Lumos.

Rank #12,724 / 21,677

355.0 W STC · Higher Than 39.9%

355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,533

18.39% Aperture Efficiency

Power density 183.9 W/m2 (1.52 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.65 V at -10 C (593.4 V string) and 46.98 V at -20 C (12 max).

8 kW Reference Array

23 Panels = 8,165 W STC

Occupies 44.4 m2 (478 sq ft) producing 7,611 W PTC; NEC 690.8 OCPD floor is 17.78 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.324/100) * (-10 - 25)) = 45.65 V | OCPD = 1.56 * 11.4 = 17.78 A

Inputs from CEC Modules.csv for Lumos S60-355-13-IM: Voc=41.0 V, beta_Voc=-0.324%/C, Isc=11.4 A, STC=355.0 W, Area=1.93 m2.

Result: 13 panels max on 600 V (593.4 V); 23 panels for 8 kW (478 sq ft).

What Are the Published CEC Specifications for Lumos S60-355-13-IM?

Laboratory test ratings recorded for Lumos S60-355-13-IM (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Lumos S60-355-13-IM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 355.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 330.9 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.4 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.94 V / 10.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.39% (1.93 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Lumos S60-355-13-IM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (478 sq ft at 8 kW), and estimated Year-1 electric bill offset for Lumos S60-355-13-IM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.04 kW 353 sq ft $1,512 $2,556
8 kW Class 23 8.16 kW 478 sq ft $2,042 $3,454
10 kW Class 29 10.29 kW 602 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Lumos Series?

Sibling wattage bins and frame colors grouped with Lumos S60-355-13-IM under Lumos to prevent duplicate spec pages. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Lumos S60-355-13-IM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Lumos S60-350-13-IM 350.0 W 326.1 W 40.9 V 32.84 V 18.13%
Lumos S60-355-13-IM 355.0 W 330.9 W 41.0 V 32.94 V 18.39%

How Many Lumos S60-355-13-IM Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Lumos S60-355-13-IM (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.0V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.98 V 12 panels 563.8 V 21 panels
-10 C (14 F) 45.65 V 13 panels 593.4 V 21 panels
0 C (32 F) 44.32 V 13 panels 576.2 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Lumos S60-355-13-IM?

Closest cross-brand CEC competitors to Lumos S60-355-13-IM matched near 355.0 W STC and 41.0 V Voc, led by Aptos Solar Technology LLC DNA-120-BF26-365W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-120-BF26-365W
Aptos Solar Technology LLC
365.0 W +10.0 W 40.59 V 20.74% 92.2%
Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC-BF
Boviet Solar Technology Co Ltd
365.0 W +10.0 W 40.38 V 19.52% 94.0%
Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC-BF-DG
Boviet Solar Technology Co Ltd
365.0 W +10.0 W 40.38 V 19.52% 94.2%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF
Boviet Solar Technology Co Ltd
380.0 W +25.0 W 40.94 V 20.32% 94.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lumos S60-355-13-IM?

Evaluate Lumos S60-355-13-IM (355.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lumos S60-355-13-IM reaches 46.98 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (478 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lumos S60-355-13-IM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lumos S60-355-13-IM 8 kW Residential Fit

Needs 23 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BF26-365W.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 330.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lumos S60-355-13-IM by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What fuse or breaker size does NEC 690.8 require for Lumos S60-355-13-IM?

Multiplying Lumos S60-355-13-IM's 11.4 A short-circuit current by 1.56 equals 17.78 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Lumos S60-355-13-IM before finalizing component orders.

Can Lumos S60-355-13-IM pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.65 V cold Voc at 14 F and handles 11.4 A Isc; string inverters cap Lumos S60-355-13-IM at 13 panels on 600 V.

Is Lumos S60-355-13-IM eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lumos S60-355-13-IM rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.