Lumos GSX 72/72 is a 360.0 W STC (334.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 17.91% efficiency, 47.6 V Voc at 25 C, and 52.25 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 334.9 W
- Voc @ 25C
- 47.6 V
- Efficiency
- 17.91%
How Does Lumos GSX 72/72 Compare Against Peer CEC Listings?
Solar engineering breakdown for Lumos GSX 72/72: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 360.0 W STC and 334.9 W PTC, Lumos GSX 72/72 sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 179.1 W/m2 (2.00 percentage points below 19.91% CEC median). Mid-range 47.6 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Auxin Solar AXN6M612B360 rates 360.0 W.
Where Does Lumos GSX 72/72 Fall Across Listed CEC Models?
Distribution marker showing Lumos GSX 72/72 (360.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Lumos GSX 72/72?
Dataset percentiles tracking Lumos GSX 72/72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Lumos GSX 72/72?
Benchmark highlights for Lumos GSX 72/72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.91% Aperture Efficiency
Power density 179.1 W/m2 (2.00 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.25 V at -10 C (574.8 V string) and 53.58 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 46.2 m2 (498 sq ft) producing 7,703 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.6 * (1 + (-0.279/100) * (-10 - 25)) = 52.25 V | OCPD = 1.56 * 9.99 = 15.58 A
Inputs from CEC Modules.csv for Lumos GSX 72/72: Voc=47.6 V, beta_Voc=-0.279%/C, Isc=9.99 A, STC=360.0 W, Area=2.01 m2.
Result: 11 panels max on 600 V (574.8 V); 23 panels for 8 kW (498 sq ft).
What Are the Published CEC Specifications for Lumos GSX 72/72?
Official CEC datasheet figures for Lumos GSX 72/72 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 334.9 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.6 V / 9.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.91% (2.01 m2) | Array roof footprint density |
| Cell Count & Technology | 12 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Lumos GSX 72/72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Lumos GSX 72/72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 368 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 498 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 606 sq ft | $2,523 | $4,266 |
How Many Lumos GSX 72/72 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Lumos GSX 72/72 (52.25 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.58 V | 11 panels | 589.4 V | 18 panels |
| -10 C (14 F) | 52.25 V | 11 panels | 574.8 V | 19 panels |
| 0 C (32 F) | 50.92 V | 11 panels | 560.1 V | 19 panels |
| 25 C (77 F STC) | 47.6 V | 12 panels | 571.2 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Lumos GSX 72/72?
Competing CEC solar panels closest to Lumos GSX 72/72 in nameplate wattage and Voc, starting with Auxin Solar AXN6M612B360.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612B360 Auxin Solar |
360.0 W | Tie (0 W) | 47.56 V | 18.28% | 93.0% |
| CSI Solar Co Ltd CS3U-360MB-AG CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 47.0 V | 18.56% | 93.8% |
| CSI Solar Co Ltd CS3U-360PB-AG CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 47.0 V | 18.56% | 92.5% |
| CSI Solar Co Ltd CS3U-380PB-AG CSI Solar Co Ltd |
380.0 W | +20.0 W | 47.8 V | 19.29% | 93.5% |
What Are the Design Limits and Best-Fit Uses for Lumos GSX 72/72?
Evaluate Lumos GSX 72/72 (360.0 W STC, 47.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lumos GSX 72/72 reaches 53.58 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 498 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (498 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos GSX 72/72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lumos GSX 72/72 8 kW Residential Fit
Needs 23 modules (498 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B360.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 334.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lumos GSX 72/72 by Lumos grounded in CEC test data and NEC 690.7/690.8 limits.
How many Lumos GSX 72/72 panels fit on a 600 V winter solar string?
At -10 C (14 F), Lumos GSX 72/72 cold Voc rises from 47.6 V to 52.25 V (beta_Voc -0.279%/C), capping a 600 V string at 11 panels (574.8 V).
How much roof area does an 8 kW array of Lumos GSX 72/72 need?
An 8 kW DC system uses 23 Lumos GSX 72/72 modules (8,280 W STC / 7,703 W PTC), covering roughly 498 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does Lumos GSX 72/72 compare against Auxin Solar AXN6M612B360?
Lumos GSX 72/72 outputs 360.0 W STC (47.6 V Voc, rank #12,385 of 21,677), while Auxin Solar AXN6M612B360 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)