Gintung Energy GTEC-235G6M69 is a 235.0 W STC (207.0 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 16.04% efficiency, 34.06 V Voc at 25 C, and 38.15 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 207.0 W
- Voc @ 25C
- 34.06 V
- Efficiency
- 16.04%
How Does Gintung Energy GTEC-235G6M69 Compare Against Peer CEC Listings?
Solar engineering breakdown for Gintung Energy GTEC-235G6M69: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Measured at 235.0 W STC and 207.0 W PTC, Gintung Energy GTEC-235G6M69 sits -150.0 W vs all-CEC median (below all-CEC median; higher than 5.4% of peers) among 21,677 listed modules. Power density reaches 160.4 W/m2 (3.87 percentage points below 19.91% CEC median). Lower 34.06 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 26 panels in series. Alternative peer Centrosolar America DP54 230 rates 230.0 W.
Where Does Gintung Energy GTEC-235G6M69 Fall Across Listed CEC Models?
Distribution marker showing Gintung Energy GTEC-235G6M69 (235.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Gintung Energy GTEC-235G6M69?
Dataset percentiles tracking Gintung Energy GTEC-235G6M69 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Gintung Energy GTEC-235G6M69?
Benchmark highlights for Gintung Energy GTEC-235G6M69 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.04% Aperture Efficiency
Power density 160.4 W/m2 (3.87 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 38.15 V at -10 C (572.2 V string) and 39.32 V at -20 C (15 max).
35 Panels = 8,225 W STC
Occupies 51.3 m2 (552 sq ft) producing 7,245 W PTC; NEC 690.8 OCPD floor is 14.07 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 34.06 * (1 + (-0.343/100) * (-10 - 25)) = 38.15 V | OCPD = 1.56 * 9.02 = 14.07 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-235G6M69: Voc=34.06 V, beta_Voc=-0.343%/C, Isc=9.02 A, STC=235.0 W, Area=1.465 m2.
Result: 15 panels max on 600 V (572.2 V); 35 panels for 8 kW (552 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-235G6M69?
Official CEC datasheet figures for Gintung Energy GTEC-235G6M69 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 207.0 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 34.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.2 V / 8.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.04% (1.465 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-235G6M69 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gintung Energy GTEC-235G6M69 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 410 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 552 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 678 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-235G6M69 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-225G6M69 | 225.0 W | 197.9 W | 33.83 V | 26.88 V | 15.36% |
| Gintung Energy GTEC-230G6M69 | 230.0 W | 202.5 W | 33.93 V | 27.03 V | 15.7% |
| Gintung Energy GTEC-235G6M69 | 235.0 W | 207.0 W | 34.06 V | 27.2 V | 16.04% |
| Gintung Energy GTEC-240G6M69 | 240.0 W | 211.6 W | 34.19 V | 27.37 V | 16.39% |
| Gintung Energy GTEC-245G6M69 | 245.0 W | 216.2 W | 34.36 V | 27.47 V | 16.73% |
How Many Gintung Energy GTEC-235G6M69 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-235G6M69 (38.15 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 39.32 V | 15 panels | 589.8 V | 25 panels |
| -10 C (14 F) | 38.15 V | 15 panels | 572.2 V | 26 panels |
| 0 C (32 F) | 36.98 V | 16 panels | 591.7 V | 27 panels |
| 25 C (77 F STC) | 34.06 V | 17 panels | 579.0 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-235G6M69?
Competing CEC solar panels closest to Gintung Energy GTEC-235G6M69 in nameplate wattage and Voc, starting with Centrosolar America DP54 230.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP54 230 Centrosolar America |
230.0 W | -5.0 W | 34.02 V | 15.51% | 88.7% |
| Anhui Rinengzhongtian Semiconductor Development QJP235-60 Anhui Rinengzhongtian Semiconductor Development |
235.0 W | Tie (0 W) | 36.1 V | 14.44% | 89.3% |
| Changzhou Nesl Solartech DJ-235P-ST15 Changzhou Nesl Solartech |
235.0 W | Tie (0 W) | 36.2 V | 14.39% | 90.3% |
| Anhui Rinengzhongtian Semiconductor Development QJM235-60 Anhui Rinengzhongtian Semiconductor Development |
235.0 W | Tie (0 W) | 36.65 V | 14.44% | 90.0% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-235G6M69?
Evaluate Gintung Energy GTEC-235G6M69 (235.0 W STC, 34.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-235G6M69 reaches 39.32 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 552 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (552 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-235G6M69 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-235G6M69 8 kW Residential Fit
Needs 35 modules (552 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 230.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 207.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-235G6M69 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy GTEC-235G6M69 panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy GTEC-235G6M69 cold Voc rises from 34.06 V to 38.15 V (beta_Voc -0.343%/C), capping a 600 V string at 15 panels (572.2 V).
How much roof area does an 8 kW array of Gintung Energy GTEC-235G6M69 need?
An 8 kW DC system uses 35 Gintung Energy GTEC-235G6M69 modules (8,225 W STC / 7,245 W PTC), covering roughly 552 sq ft and saving ~$2,057/yr at 18.54 c/kWh.
How does Gintung Energy GTEC-235G6M69 compare against Centrosolar America DP54 230?
Gintung Energy GTEC-235G6M69 outputs 235.0 W STC (34.06 V Voc, rank #20,368 of 21,677), while Centrosolar America DP54 230 delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)