Centrosolar America DP54 230 is a 230.0 W STC (204.0 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 15.51% efficiency, 34.02 V Voc at 25 C, and 38.31 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 230.0 W
- PTC Wattage
- 204.0 W
- Voc @ 25C
- 34.02 V
- Efficiency
- 15.51%
How Does Centrosolar America DP54 230 Compare Against Peer CEC Listings?
Solar engineering breakdown for Centrosolar America DP54 230: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Centrosolar America and peers, Centrosolar America DP54 230 stands 48.8 W below the 278.8 W Multi-c-Si median and typical 88.7% PTC-to-STC thermal output (204.0 W real-world rating). Sizing 6 kW (27 panels) to 10 kW (44 panels) yields $1,554-$2,533/yr in baseline US bill offset. Lower 34.02 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does Centrosolar America DP54 230 Fall Across Listed CEC Models?
Distribution marker showing Centrosolar America DP54 230 (230.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Centrosolar America DP54 230?
Dataset percentiles tracking Centrosolar America DP54 230 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Centrosolar America DP54 230?
Benchmark highlights for Centrosolar America DP54 230 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
230.0 W STC · Higher Than 4.7%
230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.51% Aperture Efficiency
Power density 155.1 W/m2 (4.40 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 38.31 V at -10 C (574.7 V string) and 39.53 V at -20 C (15 max).
35 Panels = 8,050 W STC
Occupies 51.9 m2 (559 sq ft) producing 7,140 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 34.02 * (1 + (-0.36/100) * (-10 - 25)) = 38.31 V | OCPD = 1.56 * 8.66 = 13.51 A
Inputs from CEC Modules.csv for Centrosolar America DP54 230: Voc=34.02 V, beta_Voc=-0.36%/C, Isc=8.66 A, STC=230.0 W, Area=1.483 m2.
Result: 15 panels max on 600 V (574.7 V); 35 panels for 8 kW (559 sq ft).
What Are the Published CEC Specifications for Centrosolar America DP54 230?
Official CEC datasheet figures for Centrosolar America DP54 230 (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 204.0 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 34.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.19 V / 8.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.51% (1.483 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America DP54 230 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Centrosolar America DP54 230 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 27 | 6.21 kW | 431 sq ft | $1,554 | $2,628 |
| 8 kW Class | 35 | 8.05 kW | 559 sq ft | $2,015 | $3,407 |
| 10 kW Class | 44 | 10.12 kW | 702 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?
Consolidated Centrosolar America wattage variants sharing the Centrosolar America DP54 230 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Centrosolar America DP54 225 | 225.0 W | 199.4 W | 33.8 V | 27.78 V | 15.17% |
| Centrosolar America DP54 230 | 230.0 W | 204.0 W | 34.02 V | 28.19 V | 15.51% |
How Many Centrosolar America DP54 230 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP54 230 (38.31 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 39.53 V | 15 panels | 593.0 V | 25 panels |
| -10 C (14 F) | 38.31 V | 15 panels | 574.7 V | 26 panels |
| 0 C (32 F) | 37.08 V | 16 panels | 593.3 V | 26 panels |
| 25 C (77 F STC) | 34.02 V | 17 panels | 578.3 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP54 230?
Competing CEC solar panels closest to Centrosolar America DP54 230 in nameplate wattage and Voc, starting with Gintung Energy ASEC-235G6M69.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-235G6M69 Gintung Energy |
235.0 W | +5.0 W | 34.06 V | 16.04% | 88.1% |
| Gintung Energy GTEC-235G6M69 Gintung Energy |
235.0 W | +5.0 W | 34.06 V | 16.04% | 88.1% |
| Gintung Energy ASEC-235G6S69 Gintung Energy |
235.0 W | +5.0 W | 34.13 V | 16.04% | 87.7% |
| Gintung Energy GTEC-235G6S69 Gintung Energy |
235.0 W | +5.0 W | 34.13 V | 16.04% | 87.7% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America DP54 230?
Evaluate Centrosolar America DP54 230 (230.0 W STC, 34.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP54 230 reaches 39.53 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 559 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (559 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP54 230 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America DP54 230 8 kW Residential Fit
Needs 35 modules (559 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-235G6M69.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 204.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America DP54 230 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Centrosolar America DP54 230?
Multiplying Centrosolar America DP54 230's 8.66 A short-circuit current by 1.56 equals 13.51 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Centrosolar America DP54 230 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 38.31 V cold Voc at 14 F and handles 8.66 A Isc; string inverters cap Centrosolar America DP54 230 at 15 panels on 600 V.
Is Centrosolar America DP54 230 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP54 230 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)