Gintung Energy GTEC-235G6S69 — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-235G6S69 is a 235.0 W STC (206.2 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 16.04% efficiency, 34.13 V Voc at 25 C, and 38.23 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
206.2 W
Voc @ 25C
34.13 V
Efficiency
16.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-235G6S69 Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-235G6S69 handles rooftop heat (206.2 W PTC), 8 kW sizing, and cold winter string voltage.

Gintung Energy builds the Gintung Energy GTEC-235G6S69 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 160.4 W/m2 (3.87 percentage points below 19.91% CEC median). Compared against Centrosolar America DP54 230 (230.0 W), this model holds typical 87.7% PTC-to-STC thermal output (206.2 W real-world rating). Lower 34.13 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.04 A overcurrent floor served by a 15 A breaker.

Where Does Gintung Energy GTEC-235G6S69 Fall Across Listed CEC Models?

Where Gintung Energy GTEC-235G6S69 (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-235G6S69 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 235.0 W

What Dataset Percentiles Define Gintung Energy GTEC-235G6S69?

Percentile placement of Gintung Energy GTEC-235G6S69 across power density (160.4 W/m2), thermal retention, and nameplate STC wattage.

Gintung Energy GTEC-235G6S69 Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-235G6S69 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention87.7%Module Efficiency16.04%

What Do the Dataset Ranks Show for Gintung Energy GTEC-235G6S69?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-235G6S69 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,090

16.04% Aperture Efficiency

Power density 160.4 W/m2 (3.87 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.23 V at -10 C (573.4 V string) and 39.4 V at -20 C (15 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 51.3 m2 (552 sq ft) producing 7,217 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 34.13 * (1 + (-0.343/100) * (-10 - 25)) = 38.23 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-235G6S69: Voc=34.13 V, beta_Voc=-0.343%/C, Isc=9.0 A, STC=235.0 W, Area=1.465 m2.

Result: 15 panels max on 600 V (573.4 V); 35 panels for 8 kW (552 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-235G6S69?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-235G6S69.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-235G6S69.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 206.2 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 34.13 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.17 V / 8.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.04% (1.465 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-235G6S69 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-235G6S69 (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 410 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 552 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 678 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-235G6S69 architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Gintung Energy GTEC-235G6S69 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-225G6S69 225.0 W 197.1 W 33.92 V 26.85 V 15.36%
Gintung Energy GTEC-230G6S69 230.0 W 201.6 W 34.08 V 27.0 V 15.7%
Gintung Energy GTEC-235G6S69 235.0 W 206.2 W 34.13 V 27.17 V 16.04%
Gintung Energy GTEC-240G6S69 240.0 W 210.7 W 34.19 V 27.33 V 16.39%
Gintung Energy GTEC-245G6S69 245.0 W 215.3 W 34.29 V 27.44 V 16.73%

How Many Gintung Energy GTEC-235G6S69 Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-235G6S69 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=34.13V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 39.4 V 15 panels 591.0 V 25 panels
-10 C (14 F) 38.23 V 15 panels 573.4 V 26 panels
0 C (32 F) 37.06 V 16 panels 593.0 V 26 panels
25 C (77 F STC) 34.13 V 17 panels 580.2 V 29 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-235G6S69?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-235G6S69 (235.0 W), including Centrosolar America DP54 230.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP54 230
Centrosolar America
230.0 W -5.0 W 34.02 V 15.51% 88.7%
Anhui Rinengzhongtian Semiconductor Development QJP235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.1 V 14.44% 89.3%
Changzhou Nesl Solartech DJ-235P-ST15
Changzhou Nesl Solartech
235.0 W Tie (0 W) 36.2 V 14.39% 90.3%
Anhui Rinengzhongtian Semiconductor Development QJM235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.65 V 14.44% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-235G6S69?

Evaluate Gintung Energy GTEC-235G6S69 (235.0 W STC, 34.13 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-235G6S69 reaches 39.4 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 552 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (552 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-235G6S69 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-235G6S69 8 kW Residential Fit

Needs 35 modules (552 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 230.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 206.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-235G6S69 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-235G6S69?

Multiplying Gintung Energy GTEC-235G6S69's 9.0 A short-circuit current by 1.56 equals 14.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Gintung Energy GTEC-235G6S69 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 38.23 V cold Voc at 14 F and handles 9.0 A Isc; string inverters cap Gintung Energy GTEC-235G6S69 at 15 panels on 600 V.

Is Gintung Energy GTEC-235G6S69 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-235G6S69 rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.