LONGi Green Energy Technology Co Ltd LR6-60HIB-295M is a 295.0 W STC (274.1 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.6 V Voc at 25 C, and 43.33 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 274.1 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 18.21%
How Does LONGi Green Energy Technology Co Ltd LR6-60HIB-295M Compare Against Peer CEC Listings?
Engineering position of LONGi Green Energy Technology Co Ltd LR6-60HIB-295M (295.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-M6/60295 across 5,889 CEC Mono-c-Si solar modules.
Ranking #16,890 across 21,677 CEC solar panels (below all-CEC median; higher than 20.4% of peers), LONGi Green Energy Technology Co Ltd LR6-60HIB-295M operates as a compact residential or specialty off-grid module sitting 115.0 W below the 410.0 W Mono-c-Si median. Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters. With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 28 panels occupy 488 sq ft and offset roughly $2,067/yr at average US rates (or $3,496/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does LONGi Green Energy Technology Co Ltd LR6-60HIB-295M Fall Across Listed CEC Models?
Plots LONGi Green Energy Technology Co Ltd LR6-60HIB-295M at 295.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR6-60HIB-295M?
Benchmarks LONGi Green Energy Technology Co Ltd LR6-60HIB-295M on STC wattage, thermal PTC/STC retention, and 18.21 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M by LONGi Green Energy Technology Co Ltd.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.21% Aperture Efficiency
Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.33 V at -10 C (563.3 V string) and 44.39 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,675 W PTC; NEC 690.8 OCPD floor is 14.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.269/100) * (-10 - 25)) = 43.33 V | OCPD = 1.56 * 9.59 = 14.96 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M: Voc=39.6 V, beta_Voc=-0.269%/C, Isc=9.59 A, STC=295.0 W, Area=1.62 m2.
Result: 13 panels max on 600 V (563.3 V); 28 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M?
Laboratory test ratings recorded for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 274.1 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.7 V / 9.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.21% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many LONGi Green Energy Technology Co Ltd LR6-60HIB-295M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (488 sq ft at 8 kW), and estimated Year-1 electric bill offset for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 366 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 488 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 593 sq ft | $2,510 | $4,245 |
How Many LONGi Green Energy Technology Co Ltd LR6-60HIB-295M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M (beta_Voc -0.269%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.39 V | 13 panels | 577.1 V | 22 panels |
| -10 C (14 F) | 43.33 V | 13 panels | 563.3 V | 23 panels |
| 0 C (32 F) | 42.26 V | 14 panels | 591.6 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR6-60HIB-295M?
Closest cross-brand CEC competitors to LONGi Green Energy Technology Co Ltd LR6-60HIB-295M matched near 295.0 W STC and 39.6 V Voc, led by GCL System Integration Technology Co Ltd GCL-M6/60295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | -5.0 W | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | -5.0 W | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M?
Evaluate LONGi Green Energy Technology Co Ltd LR6-60HIB-295M (295.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR6-60HIB-295M reaches 44.39 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR6-60HIB-295M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR6-60HIB-295M 8 kW Residential Fit
Needs 28 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR6-60HIB-295M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many LONGi Green Energy Technology Co Ltd LR6-60HIB-295M panels fit on a 600 V winter solar string?
At -10 C (14 F), LONGi Green Energy Technology Co Ltd LR6-60HIB-295M cold Voc rises from 39.6 V to 43.33 V (beta_Voc -0.269%/C), capping a 600 V string at 13 panels (563.3 V).
How much roof area does an 8 kW array of LONGi Green Energy Technology Co Ltd LR6-60HIB-295M need?
An 8 kW DC system uses 28 LONGi Green Energy Technology Co Ltd LR6-60HIB-295M modules (8,260 W STC / 7,675 W PTC), covering roughly 488 sq ft and saving ~$2,067/yr at 18.54 c/kWh.
How does LONGi Green Energy Technology Co Ltd LR6-60HIB-295M compare against GCL System Integration Technology Co Ltd GCL-M6/60295?
LONGi Green Energy Technology Co Ltd LR6-60HIB-295M outputs 295.0 W STC (39.6 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.