LONGi Green Energy Technology Co Ltd LR5-72HBD-560M is a 560.0 W STC (516.5 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 22.31% efficiency, 50.1 V Voc at 25 C, and 54.76 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 516.5 W
- Voc @ 25C
- 50.1 V
- Efficiency
- 22.31%
How Does LONGi Green Energy Technology Co Ltd LR5-72HBD-560M Compare Against Peer CEC Listings?
Engineering position of LONGi Green Energy Technology Co Ltd LR5-72HBD-560M (560.0 W STC) vs. ES Foundry Corp ES-DP8-H72L-560W across 5,889 CEC Mono-c-Si solar modules.
Ranking #2,404 across 21,677 CEC solar panels (top 11.8%; higher than 88.2% of peers), LONGi Green Energy Technology Co Ltd LR5-72HBD-560M operates as a large-format commercial and ground-mount module sitting 150.0 W above the 410.0 W Mono-c-Si median. Higher 50.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677), 15 panels occupy 405 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does LONGi Green Energy Technology Co Ltd LR5-72HBD-560M Fall Across Listed CEC Models?
Plots LONGi Green Energy Technology Co Ltd LR5-72HBD-560M at 560.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR5-72HBD-560M?
Benchmarks LONGi Green Energy Technology Co Ltd LR5-72HBD-560M on STC wattage, thermal PTC/STC retention, and 22.31 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M by LONGi Green Energy Technology Co Ltd.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.31% Aperture Efficiency
Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.76 V at -10 C (547.6 V string) and 56.1 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 37.6 m2 (405 sq ft) producing 7,748 W PTC; NEC 690.8 OCPD floor is 22.0 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.1 * (1 + (-0.266/100) * (-10 - 25)) = 54.76 V | OCPD = 1.56 * 14.1 = 22.0 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M: Voc=50.1 V, beta_Voc=-0.266%/C, Isc=14.1 A, STC=560.0 W, Area=2.51 m2.
Result: 10 panels max on 600 V (547.6 V); 15 panels for 8 kW (405 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M?
Laboratory test ratings recorded for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 516.5 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.25 V / 13.26 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.31% (2.51 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LONGi Green Energy Technology Co Ltd LR5-72HBD-560M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 297 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 405 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 486 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This LONGi Green Energy Technology Co Ltd Series?
Sibling wattage bins and frame colors grouped with LONGi Green Energy Technology Co Ltd LR5-72HBD-560M under LONGi Green Energy Technology Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LONGi Green Energy Technology Co Ltd LR5-72HBD-550M | 550.0 W | 506.9 W | 49.8 V | 41.95 V | 21.91% |
| LONGi Green Energy Technology Co Ltd LR5-72HBD-555M | 555.0 W | 511.7 W | 49.95 V | 42.1 V | 22.11% |
| LONGi Green Energy Technology Co Ltd LR5-72HBD-560M | 560.0 W | 516.5 W | 50.1 V | 42.25 V | 22.31% |
| LONGi Green Energy Technology Co Ltd LR5-72HBD-565M | 565.0 W | 521.2 W | 50.25 V | 42.4 V | 22.51% |
How Many LONGi Green Energy Technology Co Ltd LR5-72HBD-560M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.1 V | 10 panels | 561.0 V | 17 panels |
| -10 C (14 F) | 54.76 V | 10 panels | 547.6 V | 18 panels |
| 0 C (32 F) | 53.43 V | 11 panels | 587.7 V | 18 panels |
| 25 C (77 F STC) | 50.1 V | 11 panels | 551.1 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR5-72HBD-560M?
Closest cross-brand CEC competitors to LONGi Green Energy Technology Co Ltd LR5-72HBD-560M matched near 560.0 W STC and 50.1 V Voc, led by ES Foundry Corp ES-DP8-H72L-560W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ES Foundry Corp ES-DP8-H72L-560W ES Foundry Corp |
560.0 W | Tie (0 W) | 50.1 V | 22.31% | 92.2% |
| Bila Solar Inc AA560US-6x24GG Bila Solar Inc |
560.0 W | Tie (0 W) | 50.2 V | 22.31% | 92.9% |
| ES Foundry Corp ES-DP8-H72-560 ES Foundry Corp |
560.0 W | Tie (0 W) | 50.2 V | 21.88% | 93.9% |
| Elin Energy (Sirius PV) ELNSM72M-HC-BF-560 Elin Energy (Sirius PV) |
560.0 W | Tie (0 W) | 49.9 V | 21.88% | 94.5% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M?
Evaluate LONGi Green Energy Technology Co Ltd LR5-72HBD-560M (560.0 W STC, 50.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR5-72HBD-560M reaches 56.1 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 405 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR5-72HBD-560M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR5-72HBD-560M 8 kW Residential Fit
Needs 15 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare ES Foundry Corp ES-DP8-H72L-560W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 516.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR5-72HBD-560M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many LONGi Green Energy Technology Co Ltd LR5-72HBD-560M panels fit on a 600 V winter solar string?
At -10 C (14 F), LONGi Green Energy Technology Co Ltd LR5-72HBD-560M cold Voc rises from 50.1 V to 54.76 V (beta_Voc -0.266%/C), capping a 600 V string at 10 panels (547.6 V).
How much roof area does an 8 kW array of LONGi Green Energy Technology Co Ltd LR5-72HBD-560M need?
An 8 kW DC system uses 15 LONGi Green Energy Technology Co Ltd LR5-72HBD-560M modules (8,400 W STC / 7,748 W PTC), covering roughly 405 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does LONGi Green Energy Technology Co Ltd LR5-72HBD-560M compare against ES Foundry Corp ES-DP8-H72L-560W?
LONGi Green Energy Technology Co Ltd LR5-72HBD-560M outputs 560.0 W STC (50.1 V Voc, rank #2,404 of 21,677), while ES Foundry Corp ES-DP8-H72L-560W delivers 560.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)