LONGi Green Energy Technology Co Ltd LR5-78HBD-585M is a 585.0 W STC (552.6 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 21.51% efficiency, 53.6 V Voc at 25 C, and 58.03 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 552.6 W
- Voc @ 25C
- 53.6 V
- Efficiency
- 21.51%
How Does LONGi Green Energy Technology Co Ltd LR5-78HBD-585M Compare Against Peer CEC Listings?
How LONGi Green Energy Technology Co Ltd LONGi Green Energy Technology Co Ltd LR5-78HBD-585M handles rooftop heat (552.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, LONGi Green Energy Technology Co Ltd LR5-78HBD-585M exhibits 13.84 A short-circuit current, requiring a 21.59 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,751 of 21,677 (175.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.1 m2 for an 8 kW system (18 panels for 10 kW). Higher 53.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does LONGi Green Energy Technology Co Ltd LR5-78HBD-585M Fall Across Listed CEC Models?
Where LONGi Green Energy Technology Co Ltd LR5-78HBD-585M (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
Percentile placement of LONGi Green Energy Technology Co Ltd LR5-78HBD-585M across power density (215.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
Four critical engineering numbers homeowners and solar installers check first when reviewing LONGi Green Energy Technology Co Ltd LR5-78HBD-585M specifications.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.51% Aperture Efficiency
Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.03 V at -10 C (580.3 V string) and 59.29 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 38.1 m2 (410 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 21.59 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.6 * (1 + (-0.236/100) * (-10 - 25)) = 58.03 V | OCPD = 1.56 * 13.84 = 21.59 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M: Voc=53.6 V, beta_Voc=-0.236%/C, Isc=13.84 A, STC=585.0 W, Area=2.72 m2.
Result: 10 panels max on 600 V (580.3 V); 14 panels for 8 kW (410 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 552.6 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.1 V / 12.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.51% (2.72 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LONGi Green Energy Technology Co Ltd LR5-78HBD-585M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LONGi Green Energy Technology Co Ltd LR5-78HBD-585M (585.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 322 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 410 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 527 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This LONGi Green Energy Technology Co Ltd Series?
All closely matched LONGi Green Energy Technology Co Ltd wattages and cosmetic trims sharing the LONGi Green Energy Technology Co Ltd LR5-78HBD-585M architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LONGi Green Energy Technology Co Ltd LR5-78HBD-575M | 575.0 W | 543.0 W | 53.3 V | 44.78 V | 21.14% |
| LONGi Green Energy Technology Co Ltd LR5-78HBD-580M | 580.0 W | 547.8 W | 53.45 V | 44.94 V | 21.32% |
| LONGi Green Energy Technology Co Ltd LR5-78HBD-585M | 585.0 W | 552.6 W | 53.6 V | 45.1 V | 21.51% |
| LONGi Green Energy Technology Co Ltd LR5-78HBD-590M | 590.0 W | 557.5 W | 53.75 V | 45.25 V | 21.69% |
| LONGi Green Energy Technology Co Ltd LR5-78HBD-595M | 595.0 W | 562.3 W | 53.9 V | 45.39 V | 21.88% |
How Many LONGi Green Energy Technology Co Ltd LR5-78HBD-585M Modules Fit in a Cold-Weather String?
Maximum series module counts for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.29 V | 10 panels | 592.9 V | 16 panels |
| -10 C (14 F) | 58.03 V | 10 panels | 580.3 V | 17 panels |
| 0 C (32 F) | 56.76 V | 10 panels | 567.6 V | 17 panels |
| 25 C (77 F STC) | 53.6 V | 11 panels | 589.6 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
Alternative CEC solar modules from competing brands near LONGi Green Energy Technology Co Ltd LR5-78HBD-585M (585.0 W), including Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.0% |
| Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF-DG Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.1% |
| FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585 FS GREEN ENERGIES PRIVATE LIMITED |
585.0 W | Tie (0 W) | 53.1 V | 22.85% | 95.0% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-585 GOLDI SUN PRIVATE LIMITED |
585.0 W | Tie (0 W) | 53.1 V | 22.67% | 93.8% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
Evaluate LONGi Green Energy Technology Co Ltd LR5-78HBD-585M (585.0 W STC, 53.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR5-78HBD-585M reaches 59.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR5-78HBD-585M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR5-78HBD-585M 8 kW Residential Fit
Needs 14 modules (410 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 552.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is LONGi Green Energy Technology Co Ltd LR5-78HBD-585M PTC wattage (552.6 W) lower than STC (585.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 552.6 W PTC (94.5% retention) across LONGi Green Energy Technology Co Ltd LR5-78HBD-585M's 2.72 m2 aperture.
Who should skip LONGi Green Energy Technology Co Ltd LR5-78HBD-585M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 LONGi Green Energy Technology Co Ltd LR5-78HBD-585M panels (410 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.
What is the 1,000 V commercial string limit for LONGi Green Energy Technology Co Ltd LR5-78HBD-585M?
On 1,000 V commercial inverters at -10 C (58.03 V cold Voc), LONGi Green Energy Technology Co Ltd LR5-78HBD-585M fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)