DualSun SAS DualSun 290M-60-00 is a 290.0 W STC (263.6 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 17.68% efficiency, 39.7 V Voc at 25 C, and 43.65 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 263.6 W
- Voc @ 25C
- 39.7 V
- Efficiency
- 17.68%
How Does DualSun SAS DualSun 290M-60-00 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for DualSun SAS DualSun 290M-60-00 (Mono-c-Si) residential solar systems.
DualSun SAS DualSun 290M-60-00 delivers 176.8 W/m2 (2.23 percentage points below 19.91% CEC median) and typical 90.9% PTC-to-STC thermal output (263.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft). At -4 F (-20 C), string voltage climbs to 44.77 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with CertainTeed CT290M10-02 (290.0 W).
Where Does DualSun SAS DualSun 290M-60-00 Fall Across Listed CEC Models?
Comparison of DualSun SAS DualSun 290M-60-00 (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define DualSun SAS DualSun 290M-60-00?
Relative ranking of DualSun SAS DualSun 290M-60-00 across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for DualSun SAS DualSun 290M-60-00?
Summary of DualSun SAS DualSun 290M-60-00 output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.68% Aperture Efficiency
Power density 176.8 W/m2 (2.23 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.65 V at -10 C (567.4 V string) and 44.77 V at -20 C (13 max).
28 Panels = 8,120 W STC
Occupies 45.9 m2 (494 sq ft) producing 7,381 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.7 * (1 + (-0.284/100) * (-10 - 25)) = 43.65 V | OCPD = 1.56 * 9.58 = 14.94 A
Inputs from CEC Modules.csv for DualSun SAS DualSun 290M-60-00: Voc=39.7 V, beta_Voc=-0.284%/C, Isc=9.58 A, STC=290.0 W, Area=1.64 m2.
Result: 13 panels max on 600 V (567.4 V); 28 panels for 8 kW (494 sq ft).
What Are the Published CEC Specifications for DualSun SAS DualSun 290M-60-00?
Complete CEC test sheet for DualSun SAS DualSun 290M-60-00 including Isc (9.58 A), Voc (39.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 263.6 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.3 V / 8.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.68% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many DualSun SAS DualSun 290M-60-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using DualSun SAS DualSun 290M-60-00.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 371 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 494 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 618 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?
Related DualSun SAS power steps and black/silver trims consolidated into this DualSun SAS DualSun 290M-60-00 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| DualSun SAS DualSun 280M-60-00 | 280.0 W | 254.2 W | 39.3 V | 32.0 V | 17.07% |
| DualSun SAS DualSun 285M-60-00 | 285.0 W | 258.9 W | 39.5 V | 32.1 V | 17.38% |
| DualSun SAS DualSun 290M-60-00 | 290.0 W | 263.6 W | 39.7 V | 32.3 V | 17.68% |
| DualSun SAS DualSun 295M-60-00 | 295.0 W | 268.2 W | 39.9 V | 32.6 V | 17.99% |
How Many DualSun SAS DualSun 290M-60-00 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for DualSun SAS DualSun 290M-60-00 (39.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.77 V | 13 panels | 582.0 V | 22 panels |
| -10 C (14 F) | 43.65 V | 13 panels | 567.4 V | 22 panels |
| 0 C (32 F) | 42.52 V | 14 panels | 595.3 V | 23 panels |
| 25 C (77 F STC) | 39.7 V | 15 panels | 595.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 290M-60-00?
Four comparable CEC modules such as CertainTeed CT290M10-02 (290.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| CertainTeed CT290M11-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| AXITEC AC-290M/60S AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 290M-60-00?
Evaluate DualSun SAS DualSun 290M-60-00 (290.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 290M-60-00 reaches 44.77 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 494 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (494 sq ft).
- 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 290M-60-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
DualSun SAS DualSun 290M-60-00 8 kW Residential Fit
Needs 28 modules (494 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT290M10-02.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 263.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for DualSun SAS DualSun 290M-60-00 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.
How many DualSun SAS DualSun 290M-60-00 panels fit on a 600 V winter solar string?
At -10 C (14 F), DualSun SAS DualSun 290M-60-00 cold Voc rises from 39.7 V to 43.65 V (beta_Voc -0.284%/C), capping a 600 V string at 13 panels (567.4 V).
How much roof area does an 8 kW array of DualSun SAS DualSun 290M-60-00 need?
An 8 kW DC system uses 28 DualSun SAS DualSun 290M-60-00 modules (8,120 W STC / 7,381 W PTC), covering roughly 494 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does DualSun SAS DualSun 290M-60-00 compare against CertainTeed CT290M10-02?
DualSun SAS DualSun 290M-60-00 outputs 290.0 W STC (39.7 V Voc, rank #17,253 of 21,677), while CertainTeed CT290M10-02 delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)