Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MG61-C340 is a 340.0 W STC (311.4 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 18.68% efficiency, 44.2 V Voc at 25 C, and 49.35 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
311.4 W
Voc @ 25C
44.2 V
Efficiency
18.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MG61-C340 Compare Against Peer CEC Listings?

How LOF SOLAR CORP LOF SOLAR CORP LOF-MG61-C340 handles rooftop heat (311.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, LOF SOLAR CORP LOF-MG61-C340 exhibits 10.0 A short-circuit current, requiring a 15.6 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #13,575 of 21,677 (70.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.7 m2 for an 8 kW system (30 panels for 10 kW). Mid-range 44.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does LOF SOLAR CORP LOF-MG61-C340 Fall Across Listed CEC Models?

Where LOF SOLAR CORP LOF-MG61-C340 (340.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MG61-C340 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 340.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MG61-C340?

Percentile placement of LOF SOLAR CORP LOF-MG61-C340 across power density (186.8 W/m2), thermal retention, and nameplate STC wattage.

LOF SOLAR CORP LOF-MG61-C340 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MG61-C340 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention91.6%Module Efficiency18.68%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MG61-C340?

Four critical engineering numbers homeowners and solar installers check first when reviewing LOF SOLAR CORP LOF-MG61-C340 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,048

18.68% Aperture Efficiency

Power density 186.8 W/m2 (1.23 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.35 V at -10 C (592.2 V string) and 50.82 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 43.7 m2 (470 sq ft) producing 7,474 W PTC; NEC 690.8 OCPD floor is 15.6 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.333/100) * (-10 - 25)) = 49.35 V | OCPD = 1.56 * 10.0 = 15.6 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MG61-C340: Voc=44.2 V, beta_Voc=-0.333%/C, Isc=10.0 A, STC=340.0 W, Area=1.82 m2.

Result: 12 panels max on 600 V (592.2 V); 24 panels for 8 kW (470 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MG61-C340?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LOF SOLAR CORP LOF-MG61-C340.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MG61-C340.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 311.4 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.7 V / 9.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.333 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.68% (1.82 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MG61-C340 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LOF SOLAR CORP LOF-MG61-C340 (340.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 353 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 470 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 588 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

All closely matched LOF SOLAR CORP wattages and cosmetic trims sharing the LOF SOLAR CORP LOF-MG61-C340 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MG61-C340 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LOF SOLAR CORP LOF-MG61-C325 325.0 W 297.2 W 43.6 V 36.1 V 17.86%
LOF SOLAR CORP LOF-MG61-C330 330.0 W 301.9 W 43.8 V 36.3 V 18.13%
LOF SOLAR CORP LOF-MG61-C340 340.0 W 311.4 W 44.2 V 36.7 V 18.68%
LOF SOLAR CORP LOF-MG61-C345 345.0 W 316.1 W 44.4 V 36.9 V 18.96%

How Many LOF SOLAR CORP LOF-MG61-C340 Modules Fit in a Cold-Weather String?

Maximum series module counts for LOF SOLAR CORP LOF-MG61-C340 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.2V and beta_Voc=-0.333%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.82 V 11 panels 559.0 V 19 panels
-10 C (14 F) 49.35 V 12 panels 592.2 V 20 panels
0 C (32 F) 47.88 V 12 panels 574.6 V 20 panels
25 C (77 F STC) 44.2 V 13 panels 574.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MG61-C340?

Alternative CEC solar modules from competing brands near LOF SOLAR CORP LOF-MG61-C340 (340.0 W), including CSI Solar Co Ltd CS6XH-345M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6XH-345M
CSI Solar Co Ltd
345.0 W +5.0 W 44.4 V 18.65% 92.8%
CSI Solar Co Ltd CS1H-335MS
CSI Solar Co Ltd
335.0 W -5.0 W 43.6 V 20.55% 93.4%
AXITEC AC-340M/72S
AXITEC
340.0 W Tie (0 W) 46.16 V 17.62% 91.1%
AXITEC AC-340M/72V
AXITEC
340.0 W Tie (0 W) 46.16 V 17.62% 91.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MG61-C340?

Evaluate LOF SOLAR CORP LOF-MG61-C340 (340.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MG61-C340 reaches 50.82 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (470 sq ft).
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MG61-C340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MG61-C340 8 kW Residential Fit

Needs 24 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-345M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MG61-C340 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

Why is LOF SOLAR CORP LOF-MG61-C340 PTC wattage (311.4 W) lower than STC (340.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 311.4 W PTC (91.6% retention) across LOF SOLAR CORP LOF-MG61-C340's 1.82 m2 aperture.

Who should skip LOF SOLAR CORP LOF-MG61-C340 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 LOF SOLAR CORP LOF-MG61-C340 panels (470 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6XH-345M.

What is the 1,000 V commercial string limit for LOF SOLAR CORP LOF-MG61-C340?

On 1,000 V commercial inverters at -10 C (49.35 V cold Voc), LOF SOLAR CORP LOF-MG61-C340 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting LOF SOLAR CORP LOF-MG61-C340.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.