AXITEC AC-340M/72V is a 340.0 W STC (309.6 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.62% efficiency, 46.16 V Voc at 25 C, and 51.06 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 309.6 W
- Voc @ 25C
- 46.16 V
- Efficiency
- 17.62%
How Does AXITEC AC-340M/72V Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-340M/72V (340.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-M6/72340 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, AXITEC AC-340M/72V pairs typical 91.1% PTC-to-STC thermal output (309.6 W real-world rating) with 46.16 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,430 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer GCL System Integration Technology Co Ltd GCL-M6/72340 offers a 340.0 W alternative.
Where Does AXITEC AC-340M/72V Fall Across Listed CEC Models?
Plots AXITEC AC-340M/72V at 340.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-340M/72V?
Benchmarks AXITEC AC-340M/72V on STC wattage, thermal PTC/STC retention, and 17.62 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-340M/72V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-340M/72V by AXITEC.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.62% Aperture Efficiency
Power density 176.2 W/m2 (2.29 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.06 V at -10 C (561.7 V string) and 52.45 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 46.3 m2 (499 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 14.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.16 * (1 + (-0.303/100) * (-10 - 25)) = 51.06 V | OCPD = 1.56 * 9.48 = 14.79 A
Inputs from CEC Modules.csv for AXITEC AC-340M/72V: Voc=46.16 V, beta_Voc=-0.303%/C, Isc=9.48 A, STC=340.0 W, Area=1.93 m2.
Result: 11 panels max on 600 V (561.7 V); 24 panels for 8 kW (499 sq ft).
What Are the Published CEC Specifications for AXITEC AC-340M/72V?
Laboratory test ratings recorded for AXITEC AC-340M/72V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 309.6 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.57 V / 9.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.62% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-340M/72V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (499 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-340M/72V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 374 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 499 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 623 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-340M/72V under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-335M/72V | 335.0 W | 304.9 W | 46.04 V | 37.44 V | 17.36% |
| AXITEC AC-340M/72V | 340.0 W | 309.6 W | 46.16 V | 37.57 V | 17.62% |
| AXITEC AC-345M/72V | 345.0 W | 314.3 W | 46.61 V | 37.96 V | 17.88% |
How Many AXITEC AC-340M/72V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-340M/72V (beta_Voc -0.303%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.45 V | 11 panels | 577.0 V | 19 panels |
| -10 C (14 F) | 51.06 V | 11 panels | 561.7 V | 19 panels |
| 0 C (32 F) | 49.66 V | 12 panels | 595.9 V | 20 panels |
| 25 C (77 F STC) | 46.16 V | 12 panels | 553.9 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-340M/72V?
Closest cross-brand CEC competitors to AXITEC AC-340M/72V matched near 340.0 W STC and 46.16 V Voc, led by GCL System Integration Technology Co Ltd GCL-M6/72340.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-M6/72H340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.5% |
| GCL System Integration Technology Co Ltd GCL-P6/72H340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.7% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-340M/72V?
Evaluate AXITEC AC-340M/72V (340.0 W STC, 46.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-340M/72V reaches 52.45 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 499 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (499 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-340M/72V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-340M/72V 8 kW Residential Fit
Needs 24 modules (499 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72340.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-340M/72V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-340M/72V?
Multiplying AXITEC AC-340M/72V's 9.48 A short-circuit current by 1.56 equals 14.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can AXITEC AC-340M/72V pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.06 V cold Voc at 14 F and handles 9.48 A Isc; string inverters cap AXITEC AC-340M/72V at 11 panels on 600 V.
Is AXITEC AC-340M/72V eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-340M/72V rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)