Lightway Green New Energy LW290(35)P1960x990 is a 290.0 W STC (259.4 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 44.81 V Voc at 25 C, and 50.61 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 259.4 W
- Voc @ 25C
- 44.81 V
- Efficiency
- 14.95%
How Does Lightway Green New Energy LW290(35)P1960x990 Compare Against Peer CEC Listings?
Engineering position of Lightway Green New Energy LW290(35)P1960x990 (290.0 W STC) vs. Gintung Energy GTEC-290G6S across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, Lightway Green New Energy LW290(35)P1960x990 pairs typical 89.4% PTC-to-STC thermal output (259.4 W real-world rating) with 44.81 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,263 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy GTEC-290G6S offers a 290.0 W alternative.
Where Does Lightway Green New Energy LW290(35)P1960x990 Fall Across Listed CEC Models?
Plots Lightway Green New Energy LW290(35)P1960x990 at 290.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Lightway Green New Energy LW290(35)P1960x990?
Benchmarks Lightway Green New Energy LW290(35)P1960x990 on STC wattage, thermal PTC/STC retention, and 14.95 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Lightway Green New Energy LW290(35)P1960x990?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Lightway Green New Energy LW290(35)P1960x990 by Lightway Green New Energy.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.95% Aperture Efficiency
Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.61 V at -10 C (556.7 V string) and 52.27 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.3 m2 (585 sq ft) producing 7,263 W PTC; NEC 690.8 OCPD floor is 13.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.81 * (1 + (-0.37/100) * (-10 - 25)) = 50.61 V | OCPD = 1.56 * 8.49 = 13.24 A
Inputs from CEC Modules.csv for Lightway Green New Energy LW290(35)P1960x990: Voc=44.81 V, beta_Voc=-0.37%/C, Isc=8.49 A, STC=290.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (556.7 V); 28 panels for 8 kW (585 sq ft).
What Are the Published CEC Specifications for Lightway Green New Energy LW290(35)P1960x990?
Laboratory test ratings recorded for Lightway Green New Energy LW290(35)P1960x990 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 259.4 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.81 V / 8.11 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.37 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.95% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Lightway Green New Energy LW290(35)P1960x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (585 sq ft at 8 kW), and estimated Year-1 electric bill offset for Lightway Green New Energy LW290(35)P1960x990.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 585 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 731 sq ft | $2,540 | $4,296 |
How Many Lightway Green New Energy LW290(35)P1960x990 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Lightway Green New Energy LW290(35)P1960x990 (beta_Voc -0.37%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.27 V | 11 panels | 575.0 V | 19 panels |
| -10 C (14 F) | 50.61 V | 11 panels | 556.7 V | 19 panels |
| 0 C (32 F) | 48.95 V | 12 panels | 587.4 V | 20 panels |
| 25 C (77 F STC) | 44.81 V | 13 panels | 582.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW290(35)P1960x990?
Closest cross-brand CEC competitors to Lightway Green New Energy LW290(35)P1960x990 matched near 290.0 W STC and 44.81 V Voc, led by Gintung Energy GTEC-290G6S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW290(35)P1960x990?
Evaluate Lightway Green New Energy LW290(35)P1960x990 (290.0 W STC, 44.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW290(35)P1960x990 reaches 52.27 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW290(35)P1960x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lightway Green New Energy LW290(35)P1960x990 8 kW Residential Fit
Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy GTEC-290G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 259.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lightway Green New Energy LW290(35)P1960x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW290(35)P1960x990?
Multiplying Lightway Green New Energy LW290(35)P1960x990's 8.49 A short-circuit current by 1.56 equals 13.24 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Lightway Green New Energy LW290(35)P1960x990 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.61 V cold Voc at 14 F and handles 8.49 A Isc; string inverters cap Lightway Green New Energy LW290(35)P1960x990 at 11 panels on 600 V.
Is Lightway Green New Energy LW290(35)P1960x990 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW290(35)P1960x990 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)