Lightway Green New Energy LW240(29)P1650x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW240(29)P1650x990 is a 240.0 W STC (215.1 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.82% efficiency, 37.4 V Voc at 25 C, and 42.11 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
215.1 W
Voc @ 25C
37.4 V
Efficiency
14.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW240(29)P1650x990 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Lightway Green New Energy LW240(29)P1650x990 (Multi-c-Si) residential solar systems.

Lightway Green New Energy LW240(29)P1650x990 delivers 148.2 W/m2 (5.09 percentage points below 19.91% CEC median) and typical 89.6% PTC-to-STC thermal output (215.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (593 sq ft). At -4 F (-20 C), string voltage climbs to 43.46 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with AXITEC AC-240P/156-60B (240.0 W).

Where Does Lightway Green New Energy LW240(29)P1650x990 Fall Across Listed CEC Models?

Comparison of Lightway Green New Energy LW240(29)P1650x990 (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW240(29)P1650x990 (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 240.0 W

What Dataset Percentiles Define Lightway Green New Energy LW240(29)P1650x990?

Relative ranking of Lightway Green New Energy LW240(29)P1650x990 across nameplate watts, 89.6% PTC thermal ratio, and module aperture efficiency.

Lightway Green New Energy LW240(29)P1650x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW240(29)P1650x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention89.6%Module Efficiency14.82%

What Do the Dataset Ranks Show for Lightway Green New Energy LW240(29)P1650x990?

Summary of Lightway Green New Energy LW240(29)P1650x990 output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,035

14.82% Aperture Efficiency

Power density 148.2 W/m2 (5.09 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.11 V at -10 C (589.5 V string) and 43.46 V at -20 C (13 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.0 m2 (593 sq ft) producing 7,313 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.4 * (1 + (-0.36/100) * (-10 - 25)) = 42.11 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW240(29)P1650x990: Voc=37.4 V, beta_Voc=-0.36%/C, Isc=8.56 A, STC=240.0 W, Area=1.619 m2.

Result: 14 panels max on 600 V (589.5 V); 34 panels for 8 kW (593 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW240(29)P1650x990?

Complete CEC test sheet for Lightway Green New Energy LW240(29)P1650x990 including Isc (8.56 A), Voc (37.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW240(29)P1650x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 215.1 W (89.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.8 V / 8.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.82% (1.619 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW240(29)P1650x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Lightway Green New Energy LW240(29)P1650x990.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 436 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 593 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 732 sq ft $2,523 $4,266

How Many Lightway Green New Energy LW240(29)P1650x990 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Lightway Green New Energy LW240(29)P1650x990 (37.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.4V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.46 V 13 panels 565.0 V 23 panels
-10 C (14 F) 42.11 V 14 panels 589.5 V 23 panels
0 C (32 F) 40.77 V 14 panels 570.8 V 24 panels
25 C (77 F STC) 37.4 V 16 panels 598.4 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW240(29)P1650x990?

Four comparable CEC modules such as AXITEC AC-240P/156-60B (240.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-240P/156-60B
AXITEC
240.0 W Tie (0 W) 37.4 V 14.79% 89.5%
AXITEC AC-240M/156-60S
AXITEC
240.0 W Tie (0 W) 37.47 V 14.79% 90.4%
CSI Solar Co Ltd CS6P-240M
CSI Solar Co Ltd
240.0 W Tie (0 W) 37.3 V 15.5% 90.5%
CSI Solar Co Ltd CS6P-240MX
CSI Solar Co Ltd
240.0 W Tie (0 W) 37.3 V 15.5% 88.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW240(29)P1650x990?

Evaluate Lightway Green New Energy LW240(29)P1650x990 (240.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW240(29)P1650x990 reaches 43.46 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 593 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (593 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW240(29)P1650x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW240(29)P1650x990 8 kW Residential Fit

Needs 34 modules (593 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-240P/156-60B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 215.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW240(29)P1650x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Lightway Green New Energy LW240(29)P1650x990 panels fit on a 600 V winter solar string?

At -10 C (14 F), Lightway Green New Energy LW240(29)P1650x990 cold Voc rises from 37.4 V to 42.11 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (589.5 V).

How much roof area does an 8 kW array of Lightway Green New Energy LW240(29)P1650x990 need?

An 8 kW DC system uses 34 Lightway Green New Energy LW240(29)P1650x990 modules (8,160 W STC / 7,313 W PTC), covering roughly 593 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Lightway Green New Energy LW240(29)P1650x990 compare against AXITEC AC-240P/156-60B?

Lightway Green New Energy LW240(29)P1650x990 outputs 240.0 W STC (37.4 V Voc, rank #20,160 of 21,677), while AXITEC AC-240P/156-60B delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.