Lightway Green New Energy LW240(29)P1650x990 is a 240.0 W STC (215.1 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.82% efficiency, 37.4 V Voc at 25 C, and 42.11 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 215.1 W
- Voc @ 25C
- 37.4 V
- Efficiency
- 14.82%
How Does Lightway Green New Energy LW240(29)P1650x990 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Lightway Green New Energy LW240(29)P1650x990 (Multi-c-Si) residential solar systems.
Lightway Green New Energy LW240(29)P1650x990 delivers 148.2 W/m2 (5.09 percentage points below 19.91% CEC median) and typical 89.6% PTC-to-STC thermal output (215.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (593 sq ft). At -4 F (-20 C), string voltage climbs to 43.46 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with AXITEC AC-240P/156-60B (240.0 W).
Where Does Lightway Green New Energy LW240(29)P1650x990 Fall Across Listed CEC Models?
Comparison of Lightway Green New Energy LW240(29)P1650x990 (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Lightway Green New Energy LW240(29)P1650x990?
Relative ranking of Lightway Green New Energy LW240(29)P1650x990 across nameplate watts, 89.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Lightway Green New Energy LW240(29)P1650x990?
Summary of Lightway Green New Energy LW240(29)P1650x990 output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.82% Aperture Efficiency
Power density 148.2 W/m2 (5.09 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.11 V at -10 C (589.5 V string) and 43.46 V at -20 C (13 max).
34 Panels = 8,160 W STC
Occupies 55.0 m2 (593 sq ft) producing 7,313 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.4 * (1 + (-0.36/100) * (-10 - 25)) = 42.11 V | OCPD = 1.56 * 8.56 = 13.35 A
Inputs from CEC Modules.csv for Lightway Green New Energy LW240(29)P1650x990: Voc=37.4 V, beta_Voc=-0.36%/C, Isc=8.56 A, STC=240.0 W, Area=1.619 m2.
Result: 14 panels max on 600 V (589.5 V); 34 panels for 8 kW (593 sq ft).
What Are the Published CEC Specifications for Lightway Green New Energy LW240(29)P1650x990?
Complete CEC test sheet for Lightway Green New Energy LW240(29)P1650x990 including Isc (8.56 A), Voc (37.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 215.1 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.8 V / 8.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.82% (1.619 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Lightway Green New Energy LW240(29)P1650x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Lightway Green New Energy LW240(29)P1650x990.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 436 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 593 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 732 sq ft | $2,523 | $4,266 |
How Many Lightway Green New Energy LW240(29)P1650x990 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Lightway Green New Energy LW240(29)P1650x990 (37.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.46 V | 13 panels | 565.0 V | 23 panels |
| -10 C (14 F) | 42.11 V | 14 panels | 589.5 V | 23 panels |
| 0 C (32 F) | 40.77 V | 14 panels | 570.8 V | 24 panels |
| 25 C (77 F STC) | 37.4 V | 16 panels | 598.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW240(29)P1650x990?
Four comparable CEC modules such as AXITEC AC-240P/156-60B (240.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-240P/156-60B AXITEC |
240.0 W | Tie (0 W) | 37.4 V | 14.79% | 89.5% |
| AXITEC AC-240M/156-60S AXITEC |
240.0 W | Tie (0 W) | 37.47 V | 14.79% | 90.4% |
| CSI Solar Co Ltd CS6P-240M CSI Solar Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 15.5% | 90.5% |
| CSI Solar Co Ltd CS6P-240MX CSI Solar Co Ltd |
240.0 W | Tie (0 W) | 37.3 V | 15.5% | 88.3% |
What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW240(29)P1650x990?
Evaluate Lightway Green New Energy LW240(29)P1650x990 (240.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW240(29)P1650x990 reaches 43.46 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 593 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (593 sq ft).
- 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW240(29)P1650x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lightway Green New Energy LW240(29)P1650x990 8 kW Residential Fit
Needs 34 modules (593 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-240P/156-60B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 215.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lightway Green New Energy LW240(29)P1650x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Lightway Green New Energy LW240(29)P1650x990 panels fit on a 600 V winter solar string?
At -10 C (14 F), Lightway Green New Energy LW240(29)P1650x990 cold Voc rises from 37.4 V to 42.11 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (589.5 V).
How much roof area does an 8 kW array of Lightway Green New Energy LW240(29)P1650x990 need?
An 8 kW DC system uses 34 Lightway Green New Energy LW240(29)P1650x990 modules (8,160 W STC / 7,313 W PTC), covering roughly 593 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does Lightway Green New Energy LW240(29)P1650x990 compare against AXITEC AC-240P/156-60B?
Lightway Green New Energy LW240(29)P1650x990 outputs 240.0 W STC (37.4 V Voc, rank #20,160 of 21,677), while AXITEC AC-240P/156-60B delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)