Skip to main content
WireAndSun
Calculators
CEC PV Module

Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 — CEC Solar Module Specifications

Manufacturer: Jiangsu Runergy New Energy Technology Co Ltd Registry: CEC Verified Engineering Specification

Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 is a 595.0 W STC (564.3 W PTC) Mono-c-Si solar module ranking #1,462 of 21,677 CEC listings (top 7.4%; higher than 92.6% of peers). It delivers 21.25% efficiency, 54.57 V Voc at 25 C, and 58.96 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
595.0 W
PTC Wattage
564.3 W
Voc @ 25C
54.57 V
Efficiency
21.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 (Mono-c-Si) residential solar systems.

Homeowners evaluating Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 need 11 panels for 6 kW or 14 panels (422 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.23%/C) pushes open-circuit voltage to 58.96 V at 14 F and 60.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 Fall Across Listed CEC Models?

Comparison of Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 (595.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 (595.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJiangsu Runergy Ne: 595.0 W

What Dataset Percentiles Define Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

Relative ranking of Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.

Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 Engineering BenchmarksPercentile comparison of Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage595.0 WPTC/STC Retention94.8%Module Efficiency21.25%

What Do the Dataset Ranks Show for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

Summary of Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,462 / 21,677

Top 7.4% STC Output

595.0 W STC (+210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,423

21.25% Aperture Efficiency

Power density 212.5 W/m2 (1.34 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.96 V at -10 C (589.6 V string) and 60.22 V at -20 C (9 max).

8 kW Reference Array

14 Panels = 8,330 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,900 W PTC; NEC 690.8 OCPD floor is 21.89 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 54.57 * (1 + (-0.23/100) * (-10 - 25)) = 58.96 V | OCPD = 1.56 * 14.03 = 21.89 A

Inputs from CEC Modules.csv for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595: Voc=54.57 V, beta_Voc=-0.23%/C, Isc=14.03 A, STC=595.0 W, Area=2.8 m2.

Result: 10 panels max on 600 V (589.6 V); 14 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

Complete CEC test sheet for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 including Isc (14.03 A), Voc (54.57 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 595.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 564.3 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 54.57 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.99 V / 13.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.23 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.25% (2.8 m2) Array roof footprint density
Cell Count & Technology 156 cells (Mono-c-Si) Monofacial backsheet

How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.54 kW 332 sq ft $1,637 $2,768
8 kW Class 14 8.33 kW 422 sq ft $2,085 $3,525
10 kW Class 17 10.12 kW 512 sq ft $2,533 $4,283

How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 (54.57 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=54.57V and beta_Voc=-0.23%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 60.22 V 9 panels 542.0 V 16 panels
-10 C (14 F) 58.96 V 10 panels 589.6 V 16 panels
0 C (32 F) 57.71 V 10 panels 577.1 V 17 panels
25 C (77 F STC) 54.57 V 10 panels 545.7 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

Four comparable CEC modules such as GermanSolar USA Inc GSM10-144-590W (590.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GermanSolar USA Inc GSM10-144-590W
GermanSolar USA Inc
590.0 W -5.0 W 54.31 V 24.48% 95.2%
Elin Energy (Sirius PV) ELNSM78M-HC-590
Elin Energy (Sirius PV)
590.0 W -5.0 W 53.83 V 21.3% 94.3%
Elin Energy (Sirius PV) ELNSM78M-HC-LV-590
Elin Energy (Sirius PV)
590.0 W -5.0 W 53.83 V 21.3% 94.3%
Boviet Solar Technology Co Ltd BVM7613M-585-H-HC
Boviet Solar Technology Co Ltd
585.0 W -10.0 W 54.07 V 20.89% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

Evaluate Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 (595.0 W STC, 54.57 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 reaches 60.22 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 422 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 8 kW Residential Fit

Needs 14 modules (422 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare GermanSolar USA Inc GSM10-144-590W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 564.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 by Jiangsu Runergy New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 PTC wattage (564.3 W) lower than STC (595.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 564.3 W PTC (94.8% retention) across Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595's 2.8 m2 aperture.

Who should skip Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 panels (422 sq ft) leave unusable roof gaps vs. GermanSolar USA Inc GSM10-144-590W.

What is the 1,000 V commercial string limit for Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595?

On 1,000 V commercial inverters at -10 C (58.96 V cold Voc), Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595 fits up to 16 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.