Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 is a 635.0 W STC (603.5 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 23.52% efficiency, 49.51 V Voc at 25 C, and 53.58 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 635.0 W
- PTC Wattage
- 603.5 W
- Voc @ 25C
- 49.51 V
- Efficiency
- 23.52%
How Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 Compare Against Peer CEC Listings?
How Jiangsu Runergy New Energy Technology Co Ltd Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 handles rooftop heat (603.5 W PTC), 8 kW sizing, and cold winter string voltage.
Jiangsu Runergy New Energy Technology Co Ltd builds the Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 235.2 W/m2 (3.61 percentage points above 19.91% CEC median). Compared against New East Solar Energy (Cambodia) CoLtd NESE635-66THB-G12R (635.0 W), this model holds strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Higher 49.51 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 24.94 A overcurrent floor served by a 25 A breaker.
Where Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 Fall Across Listed CEC Models?
Where Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 (635.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Percentile placement of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 across power density (235.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 specifications.
Top 3.6% STC Output
635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.52% Aperture Efficiency
Power density 235.2 W/m2 (3.61 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.58 V at -10 C (589.4 V string) and 54.75 V at -20 C (10 max).
13 Panels = 8,255 W STC
Occupies 35.1 m2 (378 sq ft) producing 7,846 W PTC; NEC 690.8 OCPD floor is 24.94 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.51 * (1 + (-0.235/100) * (-10 - 25)) = 53.58 V | OCPD = 1.56 * 15.99 = 24.94 A
Inputs from CEC Modules.csv for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635: Voc=49.51 V, beta_Voc=-0.235%/C, Isc=15.99 A, STC=635.0 W, Area=2.7 m2.
Result: 11 panels max on 600 V (589.4 V); 13 panels for 8 kW (378 sq ft).
What Are the Published CEC Specifications for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 603.5 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.51 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.17 V / 15.06 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.52% (2.7 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 (635.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.35 kW | 291 sq ft | $1,589 | $2,687 |
| 8 kW Class | 13 | 8.26 kW | 378 sq ft | $2,067 | $3,496 |
| 10 kW Class | 16 | 10.16 kW | 465 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This Jiangsu Runergy New Energy Technology Co Ltd Series?
All closely matched Jiangsu Runergy New Energy Technology Co Ltd wattages and cosmetic trims sharing the Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-625 | 625.0 W | 593.7 W | 49.11 V | 41.62 V | 23.15% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-630 | 630.0 W | 598.6 W | 49.31 V | 41.89 V | 23.33% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 | 635.0 W | 603.5 W | 49.51 V | 42.17 V | 23.52% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-640 | 640.0 W | 608.3 W | 49.71 V | 42.45 V | 23.7% |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 Modules Fit in a Cold-Weather String?
Maximum series module counts for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.75 V | 10 panels | 547.5 V | 18 panels |
| -10 C (14 F) | 53.58 V | 11 panels | 589.4 V | 18 panels |
| 0 C (32 F) | 52.42 V | 11 panels | 576.6 V | 19 panels |
| 25 C (77 F STC) | 49.51 V | 12 panels | 594.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Alternative CEC solar modules from competing brands near Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 (635.0 W), including New East Solar Energy (Cambodia) CoLtd NESE635-66THB-G12R.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE635-66THB-G12R New East Solar Energy (Cambodia) CoLtd |
635.0 W | Tie (0 W) | 49.5 V | 23.61% | 95.4% |
| KOSOL ENERGIE PVT LTD KE635R KOSOL ENERGIE PVT LTD |
635.0 W | Tie (0 W) | 49.6 V | 23.69% | 95.2% |
| G-Star Pte Ltd GSD8R66T-635BT G-Star Pte Ltd |
635.0 W | Tie (0 W) | 49.64 V | 23.69% | 95.2% |
| G-Star Pte Ltd GSD8R66T-635WT G-Star Pte Ltd |
635.0 W | Tie (0 W) | 49.64 V | 23.69% | 95.2% |
What Are the Design Limits and Best-Fit Uses for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Evaluate Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 (635.0 W STC, 49.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 reaches 54.75 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 378 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 8 kW Residential Fit
Needs 13 modules (378 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE635-66THB-G12R.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 603.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 by Jiangsu Runergy New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635?
Multiplying Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635's 15.99 A short-circuit current by 1.56 equals 24.94 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.58 V cold Voc at 14 F and handles 15.99 A Isc; string inverters cap Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 at 11 panels on 600 V.
Is Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)