Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 is a 610.0 W STC (579.2 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.59% efficiency, 48.51 V Voc at 25 C, and 52.5 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 579.2 W
- Voc @ 25C
- 48.51 V
- Efficiency
- 22.59%
How Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 (Mono-c-Si) residential solar systems.
Homeowners evaluating Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 need 10 panels for 6 kW or 14 panels (407 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.235%/C) pushes open-circuit voltage to 52.5 V at 14 F and 53.64 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 Fall Across Listed CEC Models?
Comparison of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 (610.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
Relative ranking of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
Summary of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.59% Aperture Efficiency
Power density 225.9 W/m2 (2.68 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.5 V at -10 C (577.5 V string) and 53.64 V at -20 C (11 max).
14 Panels = 8,540 W STC
Occupies 37.8 m2 (407 sq ft) producing 8,109 W PTC; NEC 690.8 OCPD floor is 24.71 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.51 * (1 + (-0.235/100) * (-10 - 25)) = 52.5 V | OCPD = 1.56 * 15.84 = 24.71 A
Inputs from CEC Modules.csv for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610: Voc=48.51 V, beta_Voc=-0.235%/C, Isc=15.84 A, STC=610.0 W, Area=2.7 m2.
Result: 11 panels max on 600 V (577.5 V); 14 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
Complete CEC test sheet for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 including Isc (15.84 A), Voc (48.51 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 579.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.51 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.78 V / 14.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.59% (2.7 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 291 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 407 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 494 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This Jiangsu Runergy New Energy Technology Co Ltd Series?
Related Jiangsu Runergy New Energy Technology Co Ltd power steps and black/silver trims consolidated into this Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-600 | 600.0 W | 569.5 W | 48.11 V | 40.22 V | 22.22% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-605 | 605.0 W | 574.3 W | 48.31 V | 40.5 V | 22.41% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 | 610.0 W | 579.2 W | 48.51 V | 40.78 V | 22.59% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-615 | 615.0 W | 584.0 W | 48.71 V | 41.06 V | 22.78% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-620 | 620.0 W | 588.9 W | 48.91 V | 41.34 V | 22.96% |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 (48.51 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.64 V | 11 panels | 590.0 V | 18 panels |
| -10 C (14 F) | 52.5 V | 11 panels | 577.5 V | 19 panels |
| 0 C (32 F) | 51.36 V | 11 panels | 565.0 V | 19 panels |
| 25 C (77 F STC) | 48.51 V | 12 panels | 582.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
Four comparable CEC modules such as New East Solar Energy (Cambodia) CoLtd NESE610-66THB-G12R (610.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE610-66THB-G12R New East Solar Energy (Cambodia) CoLtd |
610.0 W | Tie (0 W) | 48.5 V | 22.68% | 95.3% |
| ELITE Solar ET-NR66TBH610GB ELITE Solar |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 95.0% |
| ELITE Solar ET-NR66TBH610GL ELITE Solar |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 95.0% |
| Hengdian Group DMEGC Magnetics Co Ltd DM610G12RT-B66yyy Hengdian Group DMEGC Magnetics Co Ltd |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 94.0% |
What Are the Design Limits and Best-Fit Uses for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
Evaluate Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 (610.0 W STC, 48.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 reaches 53.64 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 8 kW Residential Fit
Needs 14 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE610-66THB-G12R.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 579.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 by Jiangsu Runergy New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 PTC wattage (579.2 W) lower than STC (610.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 579.2 W PTC (95.0% retention) across Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610's 2.7 m2 aperture.
Who should skip Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 panels (407 sq ft) leave unusable roof gaps vs. New East Solar Energy (Cambodia) CoLtd NESE610-66THB-G12R.
What is the 1,000 V commercial string limit for Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610?
On 1,000 V commercial inverters at -10 C (52.5 V cold Voc), Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610 fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)