JA Solar JAP6-72-330/4BB is a 330.0 W STC (306.0 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.02% efficiency, 46.48 V Voc at 25 C, and 51.38 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 306.0 W
- Voc @ 25C
- 46.48 V
- Efficiency
- 17.02%
How Does JA Solar JAP6-72-330/4BB Compare Against Peer CEC Listings?
How JA Solar JA Solar JAP6-72-330/4BB handles rooftop heat (306.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, JA Solar JAP6-72-330/4BB exhibits 9.22 A short-circuit current, requiring a 14.38 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #14,165 of 21,677 (51.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 48.4 m2 for an 8 kW system (31 panels for 10 kW). Mid-range 46.48 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does JA Solar JAP6-72-330/4BB Fall Across Listed CEC Models?
Where JA Solar JAP6-72-330/4BB (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6-72-330/4BB?
Percentile placement of JA Solar JAP6-72-330/4BB across power density (170.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAP6-72-330/4BB?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-72-330/4BB specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.02% Aperture Efficiency
Power density 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.38 V at -10 C (565.2 V string) and 52.78 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.4 m2 (522 sq ft) producing 7,650 W PTC; NEC 690.8 OCPD floor is 14.38 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.48 * (1 + (-0.301/100) * (-10 - 25)) = 51.38 V | OCPD = 1.56 * 9.22 = 14.38 A
Inputs from CEC Modules.csv for JA Solar JAP6-72-330/4BB: Voc=46.48 V, beta_Voc=-0.301%/C, Isc=9.22 A, STC=330.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (565.2 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-72-330/4BB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-72-330/4BB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 306.0 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.48 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.6 V / 8.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.301 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.02% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-72-330/4BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-72-330/4BB (330.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 396 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-72-330/4BB architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6-72-325/4BB | 325.0 W | 301.2 W | 46.48 V | 37.49 V | 16.77% |
| JA Solar JAP6-72-330/4BB | 330.0 W | 306.0 W | 46.48 V | 37.6 V | 17.02% |
How Many JA Solar JAP6-72-330/4BB Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAP6-72-330/4BB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.78 V | 11 panels | 580.6 V | 18 panels |
| -10 C (14 F) | 51.38 V | 11 panels | 565.2 V | 19 panels |
| 0 C (32 F) | 49.98 V | 12 panels | 599.8 V | 20 panels |
| 25 C (77 F STC) | 46.48 V | 12 panels | 557.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-330/4BB?
Alternative CEC solar modules from competing brands near JA Solar JAP6-72-330/4BB (330.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330BW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| GCL System Integration Technology Co Ltd GCL-M6/72330 GCL System Integration Technology Co Ltd |
330.0 W | Tie (0 W) | 46.2 V | 17.01% | 90.4% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-330/4BB?
Evaluate JA Solar JAP6-72-330/4BB (330.0 W STC, 46.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-330/4BB reaches 52.78 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-330/4BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-72-330/4BB 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 306.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-72-330/4BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6-72-330/4BB PTC wattage (306.0 W) lower than STC (330.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 306.0 W PTC (92.7% retention) across JA Solar JAP6-72-330/4BB's 1.938 m2 aperture.
Who should skip JA Solar JAP6-72-330/4BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 JA Solar JAP6-72-330/4BB panels (522 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.
What is the 1,000 V commercial string limit for JA Solar JAP6-72-330/4BB?
On 1,000 V commercial inverters at -10 C (51.38 V cold Voc), JA Solar JAP6-72-330/4BB fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-72-330/4BB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)