JA Solar JAP6-60-255/MP — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-255/MP is a 255.0 W STC (225.6 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.59% efficiency, 37.78 V Voc at 25 C, and 42.33 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
225.6 W
Voc @ 25C
37.78 V
Efficiency
15.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-255/MP Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-255/MP handles rooftop heat (225.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAP6-60-255/MP exhibits 8.91 A short-circuit current, requiring a 13.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,421 of 21,677 (23.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 52.3 m2 for an 8 kW system (40 panels for 10 kW). Lower 37.78 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does JA Solar JAP6-60-255/MP Fall Across Listed CEC Models?

Where JA Solar JAP6-60-255/MP (255.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-255/MP (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 255.0 W

What Dataset Percentiles Define JA Solar JAP6-60-255/MP?

Percentile placement of JA Solar JAP6-60-255/MP across power density (156.0 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP6-60-255/MP Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-255/MP wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention88.5%Module Efficiency15.59%

What Do the Dataset Ranks Show for JA Solar JAP6-60-255/MP?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-255/MP specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,803

15.59% Aperture Efficiency

Power density 156.0 W/m2 (4.32 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.33 V at -10 C (592.6 V string) and 43.63 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,219 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.78 * (1 + (-0.344/100) * (-10 - 25)) = 42.33 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-255/MP: Voc=37.78 V, beta_Voc=-0.344%/C, Isc=8.91 A, STC=255.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (592.6 V); 32 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-255/MP?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-255/MP.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-255/MP.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 225.6 W (88.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.78 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.36 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.344 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.59% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-255/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-255/MP (255.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 422 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 563 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 704 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-60-255/MP architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the JA Solar JAP6-60-255/MP wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-250/MP 250.0 W 221.0 W 37.71 V 30.14 V 15.29%
JA Solar JAP6-60-255/MP 255.0 W 225.6 W 37.78 V 30.36 V 15.59%
JA Solar JAP6-60-260/MP 260.0 W 230.1 W 37.84 V 30.57 V 15.9%

How Many JA Solar JAP6-60-255/MP Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-255/MP from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.78V and beta_Voc=-0.344%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.63 V 13 panels 567.2 V 22 panels
-10 C (14 F) 42.33 V 14 panels 592.6 V 23 panels
0 C (32 F) 41.03 V 14 panels 574.4 V 24 panels
25 C (77 F STC) 37.78 V 15 panels 566.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-255/MP?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-255/MP (255.0 W), including GCL System Integration Technology Co Ltd GCL-P6/60255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
Eoplly New Energy Technology EP156M/60-255 AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-255/MP?

Evaluate JA Solar JAP6-60-255/MP (255.0 W STC, 37.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-255/MP reaches 43.63 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-255/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-255/MP 8 kW Residential Fit

Needs 32 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 225.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-255/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is JA Solar JAP6-60-255/MP PTC wattage (225.6 W) lower than STC (255.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 225.6 W PTC (88.5% retention) across JA Solar JAP6-60-255/MP's 1.635 m2 aperture.

Who should skip JA Solar JAP6-60-255/MP on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 JA Solar JAP6-60-255/MP panels (563 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-P6/60255.

What is the 1,000 V commercial string limit for JA Solar JAP6-60-255/MP?

On 1,000 V commercial inverters at -10 C (42.33 V cold Voc), JA Solar JAP6-60-255/MP fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-60-255/MP.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.