JA Solar JAP6-60-245 is a 245.0 W STC (218.3 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.98% efficiency, 37.68 V Voc at 25 C, and 42.48 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 245.0 W
- PTC Wattage
- 218.3 W
- Voc @ 25C
- 37.68 V
- Efficiency
- 14.98%
How Does JA Solar JAP6-60-245 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-245 (Multi-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAP6-60-245 need 25 panels for 6 kW or 33 panels (581 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft). Under NEC 690.7(A), beta_Voc (-0.364%/C) pushes open-circuit voltage to 42.48 V at 14 F and 43.85 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAP6-60-245 Fall Across Listed CEC Models?
Comparison of JA Solar JAP6-60-245 (245.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Dataset Percentiles Define JA Solar JAP6-60-245?
Relative ranking of JA Solar JAP6-60-245 across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for JA Solar JAP6-60-245?
Summary of JA Solar JAP6-60-245 output rank, 8 kW array size (33 panels), efficiency rating, and 600 V string limit.
245.0 W STC · Higher Than 7.0%
245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.98% Aperture Efficiency
Power density 149.8 W/m2 (4.93 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.48 V at -10 C (594.7 V string) and 43.85 V at -20 C (13 max).
33 Panels = 8,085 W STC
Occupies 54.0 m2 (581 sq ft) producing 7,204 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.68 * (1 + (-0.364/100) * (-10 - 25)) = 42.48 V | OCPD = 1.56 * 8.56 = 13.35 A
Inputs from CEC Modules.csv for JA Solar JAP6-60-245: Voc=37.68 V, beta_Voc=-0.364%/C, Isc=8.56 A, STC=245.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (594.7 V); 33 panels for 8 kW (581 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-60-245?
Complete CEC test sheet for JA Solar JAP6-60-245 including Isc (8.56 A), Voc (37.68 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 218.3 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.68 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.92 V / 8.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.364 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.98% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-60-245 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-245.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.12 kW | 440 sq ft | $1,532 | $2,590 |
| 8 kW Class | 33 | 8.09 kW | 581 sq ft | $2,025 | $3,424 |
| 10 kW Class | 41 | 10.04 kW | 722 sq ft | $2,513 | $4,249 |
How Many JA Solar JAP6-60-245 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAP6-60-245 (37.68 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.85 V | 13 panels | 570.1 V | 22 panels |
| -10 C (14 F) | 42.48 V | 14 panels | 594.7 V | 23 panels |
| 0 C (32 F) | 41.11 V | 14 panels | 575.5 V | 24 panels |
| 25 C (77 F STC) | 37.68 V | 15 panels | 565.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-245?
Four comparable CEC modules such as Changzhou Nesl Solartech DJ-245DA/C-ST15 (245.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Changzhou Nesl Solartech DJ-245DA/C-ST15 Changzhou Nesl Solartech |
245.0 W | Tie (0 W) | 37.82 V | 15.0% | 90.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
245.0 W | Tie (0 W) | 37.5 V | 15.09% | 88.3% |
| GermanSolar USA GSP6-60-245W GermanSolar USA |
245.0 W | Tie (0 W) | 37.5 V | 14.89% | 89.7% |
| Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T Hanwha Qcells (Qidong) Co Ltd |
245.0 W | Tie (0 W) | 37.5 V | 14.83% | 88.9% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-245?
Evaluate JA Solar JAP6-60-245 (245.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-245 reaches 43.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-245 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-60-245 8 kW Residential Fit
Needs 33 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-245DA/C-ST15.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 218.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-60-245 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6-60-245 PTC wattage (218.3 W) lower than STC (245.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 218.3 W PTC (89.1% retention) across JA Solar JAP6-60-245's 1.635 m2 aperture.
Who should skip JA Solar JAP6-60-245 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 33 JA Solar JAP6-60-245 panels (581 sq ft) leave unusable roof gaps vs. Changzhou Nesl Solartech DJ-245DA/C-ST15.
What is the 1,000 V commercial string limit for JA Solar JAP6-60-245?
On 1,000 V commercial inverters at -10 C (42.48 V cold Voc), JA Solar JAP6-60-245 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-60-245.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)