Skip to main content
WireAndSun
Calculators
CEC PV Module

GermanSolar USA GSP6-60-245W — CEC Solar Module Specifications

Manufacturer: GermanSolar USA Registry: CEC Verified Engineering Specification

GermanSolar USA GSP6-60-245W is a 245.0 W STC (219.7 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.89% efficiency, 37.5 V Voc at 25 C, and 42.22 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
245.0 W
PTC Wattage
219.7 W
Voc @ 25C
37.5 V
Efficiency
14.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GermanSolar USA GSP6-60-245W Compare Against Peer CEC Listings?

Engineering position of GermanSolar USA GSP6-60-245W (245.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W across 1,407 CEC Multi-c-Si solar modules.

Ranking #19,942 across 21,677 CEC solar panels (below all-CEC median; higher than 7.0% of peers), GermanSolar USA GSP6-60-245W operates as a compact residential or specialty off-grid module sitting 33.8 W below the 278.8 W Multi-c-Si median. Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.7% PTC-to-STC thermal output (219.7 W real-world rating), 33 panels occupy 584 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does GermanSolar USA GSP6-60-245W Fall Across Listed CEC Models?

Plots GermanSolar USA GSP6-60-245W at 245.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GermanSolar USA GSP6-60-245W (245.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGermanSolar USA GS: 245.0 W

What Dataset Percentiles Define GermanSolar USA GSP6-60-245W?

Benchmarks GermanSolar USA GSP6-60-245W on STC wattage, thermal PTC/STC retention, and 14.89 aperture conversion efficiency against CEC peers.

GermanSolar USA GSP6-60-245W Engineering BenchmarksPercentile comparison of GermanSolar USA GSP6-60-245W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage245.0 WPTC/STC Retention89.7%Module Efficiency14.89%

What Do the Dataset Ranks Show for GermanSolar USA GSP6-60-245W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for GermanSolar USA GSP6-60-245W by GermanSolar USA.

Rank #19,942 / 21,677

245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,898

14.89% Aperture Efficiency

Power density 148.9 W/m2 (5.02 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.22 V at -10 C (591.1 V string) and 43.57 V at -20 C (13 max).

8 kW Reference Array

33 Panels = 8,085 W STC

Occupies 54.3 m2 (584 sq ft) producing 7,250 W PTC; NEC 690.8 OCPD floor is 13.67 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.36/100) * (-10 - 25)) = 42.22 V | OCPD = 1.56 * 8.76 = 13.67 A

Inputs from CEC Modules.csv for GermanSolar USA GSP6-60-245W: Voc=37.5 V, beta_Voc=-0.36%/C, Isc=8.76 A, STC=245.0 W, Area=1.645 m2.

Result: 14 panels max on 600 V (591.1 V); 33 panels for 8 kW (584 sq ft).

What Are the Published CEC Specifications for GermanSolar USA GSP6-60-245W?

Laboratory test ratings recorded for GermanSolar USA GSP6-60-245W (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for GermanSolar USA GSP6-60-245W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 245.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 219.7 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.1 V / 8.14 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.89% (1.645 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many GermanSolar USA GSP6-60-245W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (584 sq ft at 8 kW), and estimated Year-1 electric bill offset for GermanSolar USA GSP6-60-245W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.12 kW 443 sq ft $1,532 $2,590
8 kW Class 33 8.09 kW 584 sq ft $2,025 $3,424
10 kW Class 41 10.04 kW 726 sq ft $2,513 $4,249

How Many GermanSolar USA GSP6-60-245W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for GermanSolar USA GSP6-60-245W (beta_Voc -0.36%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.5V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.57 V 13 panels 566.4 V 22 panels
-10 C (14 F) 42.22 V 14 panels 591.1 V 23 panels
0 C (32 F) 40.88 V 14 panels 572.3 V 24 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to GermanSolar USA GSP6-60-245W?

Closest cross-brand CEC competitors to GermanSolar USA GSP6-60-245W matched near 245.0 W STC and 37.5 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
245.0 W Tie (0 W) 37.5 V 15.09% 88.3%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245TW
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-245T
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GermanSolar USA GSP6-60-245W?

Evaluate GermanSolar USA GSP6-60-245W (245.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GermanSolar USA GSP6-60-245W reaches 43.57 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 33 panels for an 8 kW build require 584 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (584 sq ft).
  • 2026 tax credit baseline: cash residential installs of GermanSolar USA GSP6-60-245W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GermanSolar USA GSP6-60-245W 8 kW Residential Fit

Needs 33 modules (584 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 219.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GermanSolar USA GSP6-60-245W by GermanSolar USA grounded in CEC test data and NEC 690.7/690.8 limits.

How many GermanSolar USA GSP6-60-245W panels fit on a 600 V winter solar string?

At -10 C (14 F), GermanSolar USA GSP6-60-245W cold Voc rises from 37.5 V to 42.22 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (591.1 V).

How much roof area does an 8 kW array of GermanSolar USA GSP6-60-245W need?

An 8 kW DC system uses 33 GermanSolar USA GSP6-60-245W modules (8,085 W STC / 7,250 W PTC), covering roughly 584 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does GermanSolar USA GSP6-60-245W compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W?

GermanSolar USA GSP6-60-245W outputs 245.0 W STC (37.5 V Voc, rank #19,942 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W delivers 245.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.