GermanSolar USA GSM6-72-330W is a 330.0 W STC (299.2 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.84 V Voc at 25 C, and 52.71 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 299.2 W
- Voc @ 25C
- 46.84 V
- Efficiency
- 17.01%
How Does GermanSolar USA GSM6-72-330W Compare Against Peer CEC Listings?
Solar engineering breakdown for GermanSolar USA GSM6-72-330W: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Measured at 330.0 W STC and 299.2 W PTC, GermanSolar USA GSM6-72-330W sits -55.0 W vs all-CEC median (below all-CEC median; higher than 32.9% of peers) among 21,677 listed modules. Power density reaches 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). Mid-range 46.84 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Centrosolar America DM72 330 rates 330.0 W.
Where Does GermanSolar USA GSM6-72-330W Fall Across Listed CEC Models?
Distribution marker showing GermanSolar USA GSM6-72-330W (330.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define GermanSolar USA GSM6-72-330W?
Dataset percentiles tracking GermanSolar USA GSM6-72-330W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for GermanSolar USA GSM6-72-330W?
Benchmark highlights for GermanSolar USA GSM6-72-330W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.01% Aperture Efficiency
Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.71 V at -10 C (579.8 V string) and 54.39 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,480 W PTC; NEC 690.8 OCPD floor is 14.27 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.84 * (1 + (-0.358/100) * (-10 - 25)) = 52.71 V | OCPD = 1.56 * 9.15 = 14.27 A
Inputs from CEC Modules.csv for GermanSolar USA GSM6-72-330W: Voc=46.84 V, beta_Voc=-0.358%/C, Isc=9.15 A, STC=330.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (579.8 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for GermanSolar USA GSM6-72-330W?
Official CEC datasheet figures for GermanSolar USA GSM6-72-330W (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 299.2 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.31 V / 8.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.358 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.01% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GermanSolar USA GSM6-72-330W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many GermanSolar USA GSM6-72-330W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 397 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This GermanSolar USA Series?
Consolidated GermanSolar USA wattage variants sharing the GermanSolar USA GSM6-72-330W mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GermanSolar USA GSM6-72-325W | 325.0 W | 294.5 W | 46.55 V | 37.98 V | 16.75% |
| GermanSolar USA GSM6-72-330W | 330.0 W | 299.2 W | 46.84 V | 38.31 V | 17.01% |
| GermanSolar USA GSM6-72-335W | 335.0 W | 300.0 W | 46.99 V | 38.49 V | 17.26% |
How Many GermanSolar USA GSM6-72-330W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on GermanSolar USA GSM6-72-330W (52.71 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.39 V | 11 panels | 598.3 V | 18 panels |
| -10 C (14 F) | 52.71 V | 11 panels | 579.8 V | 18 panels |
| 0 C (32 F) | 51.03 V | 11 panels | 561.3 V | 19 panels |
| 25 C (77 F STC) | 46.84 V | 12 panels | 562.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to GermanSolar USA GSM6-72-330W?
Competing CEC solar panels closest to GermanSolar USA GSM6-72-330W in nameplate wattage and Voc, starting with Centrosolar America DM72 330.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM72 330 Centrosolar America |
330.0 W | Tie (0 W) | 46.9 V | 16.97% | 90.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330BW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
What Are the Design Limits and Best-Fit Uses for GermanSolar USA GSM6-72-330W?
Evaluate GermanSolar USA GSM6-72-330W (330.0 W STC, 46.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GermanSolar USA GSM6-72-330W reaches 54.39 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of GermanSolar USA GSM6-72-330W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GermanSolar USA GSM6-72-330W 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 330.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GermanSolar USA GSM6-72-330W by GermanSolar USA grounded in CEC test data and NEC 690.7/690.8 limits.
How many GermanSolar USA GSM6-72-330W panels fit on a 600 V winter solar string?
At -10 C (14 F), GermanSolar USA GSM6-72-330W cold Voc rises from 46.84 V to 52.71 V (beta_Voc -0.358%/C), capping a 600 V string at 11 panels (579.8 V).
How much roof area does an 8 kW array of GermanSolar USA GSM6-72-330W need?
An 8 kW DC system uses 25 GermanSolar USA GSM6-72-330W modules (8,250 W STC / 7,480 W PTC), covering roughly 522 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does GermanSolar USA GSM6-72-330W compare against Centrosolar America DM72 330?
GermanSolar USA GSM6-72-330W outputs 330.0 W STC (46.84 V Voc, rank #14,165 of 21,677), while Centrosolar America DM72 330 delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)