Changzhou Nesl Solartech DJ-245DA/C-ST15 — CEC Solar Module Specifications

Manufacturer: Changzhou Nesl Solartech Registry: CEC Verified Engineering Specification

Changzhou Nesl Solartech DJ-245DA/C-ST15 is a 245.0 W STC (221.3 W PTC) Mono-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 15.0% efficiency, 37.82 V Voc at 25 C, and 43.31 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
245.0 W
PTC Wattage
221.3 W
Voc @ 25C
37.82 V
Efficiency
15.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Changzhou Nesl Solartech DJ-245DA/C-ST15 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Changzhou Nesl Solartech DJ-245DA/C-ST15 (Mono-c-Si) residential solar systems.

Homeowners evaluating Changzhou Nesl Solartech DJ-245DA/C-ST15 need 25 panels for 6 kW or 33 panels (580 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (580 sq ft). Under NEC 690.7(A), beta_Voc (-0.415%/C) pushes open-circuit voltage to 43.31 V at 14 F and 44.88 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Changzhou Nesl Solartech DJ-245DA/C-ST15 Fall Across Listed CEC Models?

Comparison of Changzhou Nesl Solartech DJ-245DA/C-ST15 (245.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Changzhou Nesl Solartech DJ-245DA/C-ST15 (245.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCChangzhou Nesl Sol: 245.0 W

What Dataset Percentiles Define Changzhou Nesl Solartech DJ-245DA/C-ST15?

Relative ranking of Changzhou Nesl Solartech DJ-245DA/C-ST15 across nameplate watts, 90.3% PTC thermal ratio, and module aperture efficiency.

Changzhou Nesl Solartech DJ-245DA/C-ST15 Engineering BenchmarksPercentile comparison of Changzhou Nesl Solartech DJ-245DA/C-ST15 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage245.0 WPTC/STC Retention90.3%Module Efficiency15.0%

What Do the Dataset Ranks Show for Changzhou Nesl Solartech DJ-245DA/C-ST15?

Summary of Changzhou Nesl Solartech DJ-245DA/C-ST15 output rank, 8 kW array size (33 panels), efficiency rating, and 600 V string limit.

Rank #19,942 / 21,677

245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,736

15.0% Aperture Efficiency

Power density 150.0 W/m2 (4.91 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.31 V at -10 C (563.0 V string) and 44.88 V at -20 C (13 max).

8 kW Reference Array

33 Panels = 8,085 W STC

Occupies 53.9 m2 (580 sq ft) producing 7,303 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.82 * (1 + (-0.415/100) * (-10 - 25)) = 43.31 V | OCPD = 1.56 * 8.68 = 13.54 A

Inputs from CEC Modules.csv for Changzhou Nesl Solartech DJ-245DA/C-ST15: Voc=37.82 V, beta_Voc=-0.415%/C, Isc=8.68 A, STC=245.0 W, Area=1.633 m2.

Result: 13 panels max on 600 V (563.0 V); 33 panels for 8 kW (580 sq ft).

What Are the Published CEC Specifications for Changzhou Nesl Solartech DJ-245DA/C-ST15?

Complete CEC test sheet for Changzhou Nesl Solartech DJ-245DA/C-ST15 including Isc (8.68 A), Voc (37.82 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Changzhou Nesl Solartech DJ-245DA/C-ST15.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 245.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 221.3 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.82 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.5 V / 8.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.415 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.0% (1.633 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Changzhou Nesl Solartech DJ-245DA/C-ST15 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Changzhou Nesl Solartech DJ-245DA/C-ST15.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.12 kW 439 sq ft $1,532 $2,590
8 kW Class 33 8.09 kW 580 sq ft $2,025 $3,424
10 kW Class 41 10.04 kW 721 sq ft $2,513 $4,249

Which Sibling Wattage & Trim Variants Belong to This Changzhou Nesl Solartech Series?

Related Changzhou Nesl Solartech power steps and black/silver trims consolidated into this Changzhou Nesl Solartech DJ-245DA/C-ST15 series guide.

Sibling CEC listings grouped into the Changzhou Nesl Solartech DJ-245DA/C-ST15 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Changzhou Nesl Solartech DJ-240DA/C-ST15 240.0 W 216.7 W 37.57 V 30.3 V 14.69%
Changzhou Nesl Solartech DJ-245DA/C-ST15 245.0 W 221.3 W 37.82 V 30.5 V 15.0%

How Many Changzhou Nesl Solartech DJ-245DA/C-ST15 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Changzhou Nesl Solartech DJ-245DA/C-ST15 (37.82 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.82V and beta_Voc=-0.415%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.88 V 13 panels 583.4 V 22 panels
-10 C (14 F) 43.31 V 13 panels 563.0 V 23 panels
0 C (32 F) 41.74 V 14 panels 584.4 V 23 panels
25 C (77 F STC) 37.82 V 15 panels 567.3 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Changzhou Nesl Solartech DJ-245DA/C-ST15?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W (245.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
245.0 W Tie (0 W) 37.5 V 15.09% 88.3%
GermanSolar USA GSP6-60-245W
GermanSolar USA
245.0 W Tie (0 W) 37.5 V 14.89% 89.7%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245TW
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Changzhou Nesl Solartech DJ-245DA/C-ST15?

Evaluate Changzhou Nesl Solartech DJ-245DA/C-ST15 (245.0 W STC, 37.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Changzhou Nesl Solartech DJ-245DA/C-ST15 reaches 44.88 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 33 panels for an 8 kW build require 580 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (580 sq ft).
  • 2026 tax credit baseline: cash residential installs of Changzhou Nesl Solartech DJ-245DA/C-ST15 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Changzhou Nesl Solartech DJ-245DA/C-ST15 8 kW Residential Fit

Needs 33 modules (580 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 221.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Changzhou Nesl Solartech DJ-245DA/C-ST15 by Changzhou Nesl Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Changzhou Nesl Solartech DJ-245DA/C-ST15 PTC wattage (221.3 W) lower than STC (245.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 221.3 W PTC (90.3% retention) across Changzhou Nesl Solartech DJ-245DA/C-ST15's 1.633 m2 aperture.

Who should skip Changzhou Nesl Solartech DJ-245DA/C-ST15 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 33 Changzhou Nesl Solartech DJ-245DA/C-ST15 panels (580 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W.

What is the 1,000 V commercial string limit for Changzhou Nesl Solartech DJ-245DA/C-ST15?

On 1,000 V commercial inverters at -10 C (43.31 V cold Voc), Changzhou Nesl Solartech DJ-245DA/C-ST15 fits up to 23 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.