Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-60-235/MP — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-235/MP is a 235.0 W STC (207.3 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.37% efficiency, 37.51 V Voc at 25 C, and 42.03 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
207.3 W
Voc @ 25C
37.51 V
Efficiency
14.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-235/MP Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAP6-60-235/MP: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 235.0 W STC and 207.3 W PTC, JA Solar JAP6-60-235/MP sits -150.0 W vs all-CEC median (below all-CEC median; higher than 5.4% of peers) among 21,677 listed modules. Power density reaches 143.7 W/m2 (5.54 percentage points below 19.91% CEC median). Lower 37.51 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Advance Power API-M235 rates 235.0 W.

Where Does JA Solar JAP6-60-235/MP Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAP6-60-235/MP (235.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-235/MP (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 235.0 W

What Dataset Percentiles Define JA Solar JAP6-60-235/MP?

Dataset percentiles tracking JA Solar JAP6-60-235/MP power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAP6-60-235/MP Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-235/MP wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention88.2%Module Efficiency14.37%

What Do the Dataset Ranks Show for JA Solar JAP6-60-235/MP?

Benchmark highlights for JA Solar JAP6-60-235/MP covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,552

14.37% Aperture Efficiency

Power density 143.7 W/m2 (5.54 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.03 V at -10 C (588.4 V string) and 43.32 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.2 m2 (616 sq ft) producing 7,256 W PTC; NEC 690.8 OCPD floor is 13.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.51 * (1 + (-0.344/100) * (-10 - 25)) = 42.03 V | OCPD = 1.56 * 8.71 = 13.59 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-235/MP: Voc=37.51 V, beta_Voc=-0.344%/C, Isc=8.71 A, STC=235.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (588.4 V); 35 panels for 8 kW (616 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-235/MP?

Official CEC datasheet figures for JA Solar JAP6-60-235/MP (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-235/MP.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 207.3 W (88.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.51 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.42 V / 7.99 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.344 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.37% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-235/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAP6-60-235/MP modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 458 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 616 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 757 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAP6-60-235/MP mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the JA Solar JAP6-60-235/MP wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-225/MP 225.0 W 198.3 W 37.32 V 28.94 V 13.76%
JA Solar JAP6-60-230/MP 230.0 W 202.8 W 37.37 V 29.18 V 14.07%
JA Solar JAP6-60-235/MP 235.0 W 207.3 W 37.51 V 29.42 V 14.37%
JA Solar JAP6-60-240/MP 240.0 W 211.9 W 37.58 V 29.66 V 14.68%
JA Solar JAP6-60-245/MP 245.0 W 216.4 W 37.64 V 29.9 V 14.98%

How Many JA Solar JAP6-60-235/MP Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP6-60-235/MP (42.03 V at 14 F).

Computed from Voc=37.51V and beta_Voc=-0.344%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.32 V 13 panels 563.2 V 23 panels
-10 C (14 F) 42.03 V 14 panels 588.4 V 23 panels
0 C (32 F) 40.74 V 14 panels 570.4 V 24 panels
25 C (77 F STC) 37.51 V 15 panels 562.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-235/MP?

Competing CEC solar panels closest to JA Solar JAP6-60-235/MP in nameplate wattage and Voc, starting with Advance Power API-M235.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M235
Advance Power
235.0 W Tie (0 W) 37.5 V 14.35% 89.3%
Auxin Solar AXN6M610T235
Auxin Solar
235.0 W Tie (0 W) 37.5 V 14.35% 89.3%
APOS Energy AS235
APOS Energy
235.0 W Tie (0 W) 37.34 V 14.17% 89.7%
Gintech Energy GTE 235M
Gintech Energy
235.0 W Tie (0 W) 37.32 V 13.97% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-235/MP?

Evaluate JA Solar JAP6-60-235/MP (235.0 W STC, 37.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-235/MP reaches 43.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 616 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (616 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-235/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-235/MP 8 kW Residential Fit

Needs 35 modules (616 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-M235.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 207.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-235/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6-60-235/MP panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-60-235/MP cold Voc rises from 37.51 V to 42.03 V (beta_Voc -0.344%/C), capping a 600 V string at 14 panels (588.4 V).

How much roof area does an 8 kW array of JA Solar JAP6-60-235/MP need?

An 8 kW DC system uses 35 JA Solar JAP6-60-235/MP modules (8,225 W STC / 7,256 W PTC), covering roughly 616 sq ft and saving ~$2,057/yr at 18.54 c/kWh.

How does JA Solar JAP6-60-235/MP compare against Advance Power API-M235?

JA Solar JAP6-60-235/MP outputs 235.0 W STC (37.51 V Voc, rank #20,368 of 21,677), while Advance Power API-M235 delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.