JA Solar JAP6-60-205 is a 205.0 W STC (182.6 W PTC) Multi-c-Si solar module ranking #20,980 of 21,677 CEC listings (below all-CEC median; higher than 3.0% of peers). It delivers 12.54% efficiency, 36.32 V Voc at 25 C, and 40.51 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 205.0 W
- PTC Wattage
- 182.6 W
- Voc @ 25C
- 36.32 V
- Efficiency
- 12.54%
How Does JA Solar JAP6-60-205 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-205 (Multi-c-Si) residential solar systems.
JA Solar JAP6-60-205 delivers 125.4 W/m2 (7.37 percentage points below 19.91% CEC median) and typical 89.1% PTC-to-STC thermal output (182.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (704 sq ft). At -4 F (-20 C), string voltage climbs to 41.71 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with CSI Solar Co Ltd CS6P-210PX (210.0 W).
Where Does JA Solar JAP6-60-205 Fall Across Listed CEC Models?
Comparison of JA Solar JAP6-60-205 (205.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define JA Solar JAP6-60-205?
Relative ranking of JA Solar JAP6-60-205 across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for JA Solar JAP6-60-205?
Summary of JA Solar JAP6-60-205 output rank, 8 kW array size (40 panels), efficiency rating, and 600 V string limit.
205.0 W STC · Higher Than 3.0%
205.0 W STC (-180.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
12.54% Aperture Efficiency
Power density 125.4 W/m2 (7.37 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.51 V at -10 C (567.1 V string) and 41.71 V at -20 C (14 max).
40 Panels = 8,200 W STC
Occupies 65.4 m2 (704 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 12.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.32 * (1 + (-0.33/100) * (-10 - 25)) = 40.51 V | OCPD = 1.56 * 7.89 = 12.31 A
Inputs from CEC Modules.csv for JA Solar JAP6-60-205: Voc=36.32 V, beta_Voc=-0.33%/C, Isc=7.89 A, STC=205.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (567.1 V); 40 panels for 8 kW (704 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-60-205?
Complete CEC test sheet for JA Solar JAP6-60-205 including Isc (7.89 A), Voc (36.32 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 205.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 182.6 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.32 V / 7.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.54% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-60-205 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-205.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 30 | 6.15 kW | 528 sq ft | $1,539 | $2,603 |
| 8 kW Class | 40 | 8.2 kW | 704 sq ft | $2,052 | $3,470 |
| 10 kW Class | 49 | 10.04 kW | 862 sq ft | $2,513 | $4,249 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-60-205 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6-60-200 | 200.0 W | 178.1 W | 36.15 V | 28.12 V | 12.23% |
| JA Solar JAP6-60-205 | 205.0 W | 182.6 W | 36.32 V | 28.32 V | 12.54% |
| JA Solar JAP6-60-210 | 210.0 W | 187.2 W | 36.49 V | 28.52 V | 12.84% |
How Many JA Solar JAP6-60-205 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAP6-60-205 (36.32 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.71 V | 14 panels | 583.9 V | 23 panels |
| -10 C (14 F) | 40.51 V | 14 panels | 567.1 V | 24 panels |
| 0 C (32 F) | 39.32 V | 15 panels | 589.8 V | 25 panels |
| 25 C (77 F STC) | 36.32 V | 16 panels | 581.1 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-205?
Four comparable CEC modules such as CSI Solar Co Ltd CS6P-210PX (210.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6P-210PX CSI Solar Co Ltd |
210.0 W | +5.0 W | 36.4 V | 13.06% | 91.6% |
| Hanwha Qcells (Qidong) Co Ltd SF220-30-M210 Hanwha Qcells (Qidong) Co Ltd |
210.0 W | +5.0 W | 36.4 V | 12.71% | 90.0% |
| CSI Solar Co Ltd CS6P-200P CSI Solar Co Ltd |
200.0 W | -5.0 W | 36.2 V | 12.43% | 91.5% |
| Grape Solar GS-P-200-CSPE Grape Solar |
200.0 W | -5.0 W | 36.2 V | 12.43% | 88.5% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-205?
Evaluate JA Solar JAP6-60-205 (205.0 W STC, 36.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-205 reaches 41.71 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 704 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (704 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-205 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-60-205 8 kW Residential Fit
Needs 40 modules (704 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6P-210PX.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 182.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-60-205 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAP6-60-205 panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAP6-60-205 cold Voc rises from 36.32 V to 40.51 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (567.1 V).
How much roof area does an 8 kW array of JA Solar JAP6-60-205 need?
An 8 kW DC system uses 40 JA Solar JAP6-60-205 modules (8,200 W STC / 7,304 W PTC), covering roughly 704 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does JA Solar JAP6-60-205 compare against CSI Solar Co Ltd CS6P-210PX?
JA Solar JAP6-60-205 outputs 205.0 W STC (36.32 V Voc, rank #20,980 of 21,677), while CSI Solar Co Ltd CS6P-210PX delivers 210.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)