JA Solar JAM6-72-330/SI is a 330.0 W STC (298.3 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.02% efficiency, 46.47 V Voc at 25 C, and 51.51 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 298.3 W
- Voc @ 25C
- 46.47 V
- Efficiency
- 17.02%
How Does JA Solar JAM6-72-330/SI Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM6-72-330/SI (Mono-c-Si) residential solar systems.
JA Solar JAM6-72-330/SI delivers 170.3 W/m2 (2.89 percentage points below 19.91% CEC median) and typical 90.4% PTC-to-STC thermal output (298.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft). At -4 F (-20 C), string voltage climbs to 52.95 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W (330.0 W).
Where Does JA Solar JAM6-72-330/SI Fall Across Listed CEC Models?
Comparison of JA Solar JAM6-72-330/SI (330.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM6-72-330/SI?
Relative ranking of JA Solar JAM6-72-330/SI across nameplate watts, 90.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM6-72-330/SI?
Summary of JA Solar JAM6-72-330/SI output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.02% Aperture Efficiency
Power density 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.51 V at -10 C (566.6 V string) and 52.95 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.4 m2 (522 sq ft) producing 7,458 W PTC; NEC 690.8 OCPD floor is 14.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.47 * (1 + (-0.31/100) * (-10 - 25)) = 51.51 V | OCPD = 1.56 * 9.13 = 14.24 A
Inputs from CEC Modules.csv for JA Solar JAM6-72-330/SI: Voc=46.47 V, beta_Voc=-0.31%/C, Isc=9.13 A, STC=330.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (566.6 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for JA Solar JAM6-72-330/SI?
Complete CEC test sheet for JA Solar JAM6-72-330/SI including Isc (9.13 A), Voc (46.47 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 298.3 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.47 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.93 V / 8.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.02% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM6-72-330/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM6-72-330/SI.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 396 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM6-72-330/SI series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM6-72-325/SI | 325.0 W | 293.6 W | 46.02 V | 37.49 V | 16.77% |
| JA Solar JAM6-72-330/SI | 330.0 W | 298.3 W | 46.47 V | 37.93 V | 17.02% |
| JA Solar JAM6-72-335/SI | 335.0 W | 303.0 W | 46.76 V | 38.24 V | 17.28% |
How Many JA Solar JAM6-72-330/SI Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM6-72-330/SI (46.47 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.95 V | 11 panels | 582.5 V | 18 panels |
| -10 C (14 F) | 51.51 V | 11 panels | 566.6 V | 19 panels |
| 0 C (32 F) | 50.07 V | 11 panels | 550.8 V | 19 panels |
| 25 C (77 F STC) | 46.47 V | 12 panels | 557.6 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-330/SI?
Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W (330.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330BW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| Centrosolar America EP72 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| GCL System Integration Technology Co Ltd GCL-M6/72330 GCL System Integration Technology Co Ltd |
330.0 W | Tie (0 W) | 46.2 V | 17.01% | 90.4% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-330/SI?
Evaluate JA Solar JAM6-72-330/SI (330.0 W STC, 46.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-330/SI reaches 52.95 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-330/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM6-72-330/SI 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM6-72-330/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM6-72-330/SI panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM6-72-330/SI cold Voc rises from 46.47 V to 51.51 V (beta_Voc -0.31%/C), capping a 600 V string at 11 panels (566.6 V).
How much roof area does an 8 kW array of JA Solar JAM6-72-330/SI need?
An 8 kW DC system uses 25 JA Solar JAM6-72-330/SI modules (8,250 W STC / 7,458 W PTC), covering roughly 522 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does JA Solar JAM6-72-330/SI compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W?
JA Solar JAM6-72-330/SI outputs 330.0 W STC (46.47 V Voc, rank #14,165 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)