Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM6-72-310/SI — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM6-72-310/SI is a 310.0 W STC (279.7 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.99% efficiency, 45.57 V Voc at 25 C, and 50.51 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
279.7 W
Voc @ 25C
45.57 V
Efficiency
15.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM6-72-310/SI Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM6-72-310/SI (310.0 W STC) vs. DEHUI SOLAR POWER INC DH-72P-310W across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, JA Solar JAM6-72-310/SI pairs typical 90.2% PTC-to-STC thermal output (279.7 W real-world rating) with 45.57 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,272 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer DEHUI SOLAR POWER INC DH-72P-310W offers a 310.0 W alternative.

Where Does JA Solar JAM6-72-310/SI Fall Across Listed CEC Models?

Plots JA Solar JAM6-72-310/SI at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM6-72-310/SI (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM6-72-3: 310.0 W

What Dataset Percentiles Define JA Solar JAM6-72-310/SI?

Benchmarks JA Solar JAM6-72-310/SI on STC wattage, thermal PTC/STC retention, and 15.99 aperture conversion efficiency against CEC peers.

JA Solar JAM6-72-310/SI Engineering BenchmarksPercentile comparison of JA Solar JAM6-72-310/SI wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.2%Module Efficiency15.99%

What Do the Dataset Ranks Show for JA Solar JAM6-72-310/SI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM6-72-310/SI by JA Solar.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,133

15.99% Aperture Efficiency

Power density 160.0 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.51 V at -10 C (555.6 V string) and 51.93 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,272 W PTC; NEC 690.8 OCPD floor is 13.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.57 * (1 + (-0.31/100) * (-10 - 25)) = 50.51 V | OCPD = 1.56 * 8.85 = 13.81 A

Inputs from CEC Modules.csv for JA Solar JAM6-72-310/SI: Voc=45.57 V, beta_Voc=-0.31%/C, Isc=8.85 A, STC=310.0 W, Area=1.938 m2.

Result: 11 panels max on 600 V (555.6 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for JA Solar JAM6-72-310/SI?

Laboratory test ratings recorded for JA Solar JAM6-72-310/SI (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-72-310/SI.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 279.7 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.57 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.04 V / 8.37 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.99% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM6-72-310/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (542 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM6-72-310/SI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 417 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 542 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 688 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM6-72-310/SI under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM6-72-310/SI wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM6-72-300/SI 300.0 W 266.6 W 46.1 V 37.13 V 15.48%
JA Solar JAM6-72-305/SI 305.0 W 275.1 W 45.41 V 36.93 V 15.73%
JA Solar JAM6-72-310/SI 310.0 W 279.7 W 45.57 V 37.04 V 15.99%
JA Solar JAM6-72-315/SI 315.0 W 284.3 W 45.73 V 37.15 V 16.25%
JA Solar JAM6-72-320/SI 320.0 W 289.0 W 45.86 V 37.35 V 16.51%

How Many JA Solar JAM6-72-310/SI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM6-72-310/SI (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.57V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.93 V 11 panels 571.2 V 19 panels
-10 C (14 F) 50.51 V 11 panels 555.6 V 19 panels
0 C (32 F) 49.1 V 12 panels 589.2 V 20 panels
25 C (77 F STC) 45.57 V 13 panels 592.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-310/SI?

Closest cross-brand CEC competitors to JA Solar JAM6-72-310/SI matched near 310.0 W STC and 45.57 V Voc, led by DEHUI SOLAR POWER INC DH-72P-310W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72P-310W
DEHUI SOLAR POWER INC
310.0 W Tie (0 W) 45.6 V 16.12% 90.5%
AXITEC AC-310M/156-72S
AXITEC
310.0 W Tie (0 W) 45.49 V 16.01% 90.2%
Centrosolar America DM72 310
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.94% 90.8%
Centrosolar America TP7 310xx
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.89% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-310/SI?

Evaluate JA Solar JAM6-72-310/SI (310.0 W STC, 45.57 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-310/SI reaches 51.93 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-310/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM6-72-310/SI 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-310W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-72-310/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM6-72-310/SI?

Multiplying JA Solar JAM6-72-310/SI's 8.85 A short-circuit current by 1.56 equals 13.81 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAM6-72-310/SI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.51 V cold Voc at 14 F and handles 8.85 A Isc; string inverters cap JA Solar JAM6-72-310/SI at 11 panels on 600 V.

Is JA Solar JAM6-72-310/SI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM6-72-310/SI rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.