JA Solar JAM6-72-265 is a 265.0 W STC (237.3 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 13.57% efficiency, 44.6 V Voc at 25 C, and 49.6 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 265.0 W
- PTC Wattage
- 237.3 W
- Voc @ 25C
- 44.6 V
- Efficiency
- 13.57%
How Does JA Solar JAM6-72-265 Compare Against Peer CEC Listings?
Engineering position of JA Solar JAM6-72-265 (265.0 W STC) vs. Gintung Energy ASEC-265G6S across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, JA Solar JAM6-72-265 pairs typical 89.5% PTC-to-STC thermal output (237.3 W real-world rating) with 44.6 V nominal Voc. An 8 kW residential build (8,215 W DC, 7,356 W PTC) saves ~$2,055/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy ASEC-265G6S offers a 265.0 W alternative.
Where Does JA Solar JAM6-72-265 Fall Across Listed CEC Models?
Plots JA Solar JAM6-72-265 at 265.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM6-72-265?
Benchmarks JA Solar JAM6-72-265 on STC wattage, thermal PTC/STC retention, and 13.57 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAM6-72-265?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM6-72-265 by JA Solar.
265.0 W STC · Higher Than 11.7%
265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.57% Aperture Efficiency
Power density 135.8 W/m2 (6.34 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.6 V at -10 C (595.2 V string) and 51.02 V at -20 C (11 max).
31 Panels = 8,215 W STC
Occupies 60.5 m2 (651 sq ft) producing 7,356 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.6 * (1 + (-0.32/100) * (-10 - 25)) = 49.6 V | OCPD = 1.56 * 8.2 = 12.79 A
Inputs from CEC Modules.csv for JA Solar JAM6-72-265: Voc=44.6 V, beta_Voc=-0.32%/C, Isc=8.2 A, STC=265.0 W, Area=1.952 m2.
Result: 12 panels max on 600 V (595.2 V); 31 panels for 8 kW (651 sq ft).
What Are the Published CEC Specifications for JA Solar JAM6-72-265?
Laboratory test ratings recorded for JA Solar JAM6-72-265 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 237.3 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.33 V / 7.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.57% (1.952 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM6-72-265 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (651 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM6-72-265.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.09 kW | 483 sq ft | $1,524 | $2,577 |
| 8 kW Class | 31 | 8.21 kW | 651 sq ft | $2,055 | $3,475 |
| 10 kW Class | 38 | 10.07 kW | 798 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAM6-72-265 under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM6-72-255 | 255.0 W | 228.1 W | 44.5 V | 34.93 V | 13.06% |
| JA Solar JAM6-72-260 | 260.0 W | 232.7 W | 44.6 V | 35.14 V | 13.32% |
| JA Solar JAM6-72-265 | 265.0 W | 237.3 W | 44.6 V | 35.33 V | 13.57% |
| JA Solar JAM6-72-270 | 270.0 W | 241.9 W | 44.7 V | 35.33 V | 13.83% |
How Many JA Solar JAM6-72-265 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAM6-72-265 (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.02 V | 11 panels | 561.2 V | 19 panels |
| -10 C (14 F) | 49.6 V | 12 panels | 595.2 V | 20 panels |
| 0 C (32 F) | 48.17 V | 12 panels | 578.0 V | 20 panels |
| 25 C (77 F STC) | 44.6 V | 13 panels | 579.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-265?
Closest cross-brand CEC competitors to JA Solar JAM6-72-265 matched near 265.0 W STC and 44.6 V Voc, led by Gintung Energy ASEC-265G6S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-265G6S Gintung Energy |
265.0 W | Tie (0 W) | 44.12 V | 13.55% | 89.5% |
| CSI Solar Co Ltd CS6X-265P CSI Solar Co Ltd |
265.0 W | Tie (0 W) | 43.9 V | 14.31% | 88.8% |
| Advance Power API-M270 Advance Power |
270.0 W | +5.0 W | 44.64 V | 13.84% | 89.0% |
| Auxin Solar AXN6M612T270 Auxin Solar |
270.0 W | +5.0 W | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-265?
Evaluate JA Solar JAM6-72-265 (265.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-265 reaches 51.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (651 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-265 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM6-72-265 8 kW Residential Fit
Needs 31 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-265G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 237.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM6-72-265 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM6-72-265?
Multiplying JA Solar JAM6-72-265's 8.2 A short-circuit current by 1.56 equals 12.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAM6-72-265 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.6 V cold Voc at 14 F and handles 8.2 A Isc; string inverters cap JA Solar JAM6-72-265 at 12 panels on 600 V.
Is JA Solar JAM6-72-265 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM6-72-265 rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)