JA Solar JAM54S31-405/MR is a 405.0 W STC (378.3 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.32% efficiency, 37.23 V Voc at 25 C, and 40.6 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 378.3 W
- Voc @ 25C
- 37.23 V
- Efficiency
- 21.32%
How Does JA Solar JAM54S31-405/MR Compare Against Peer CEC Listings?
Engineering position of JA Solar JAM54S31-405/MR (405.0 W STC) vs. CertainTeed CTM10405HC11-06 across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), JA Solar JAM54S31-405/MR operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Lower 37.23 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677), 20 panels occupy 409 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAM54S31-405/MR Fall Across Listed CEC Models?
Plots JA Solar JAM54S31-405/MR at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM54S31-405/MR?
Benchmarks JA Solar JAM54S31-405/MR on STC wattage, thermal PTC/STC retention, and 21.32 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAM54S31-405/MR?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM54S31-405/MR by JA Solar.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.32% Aperture Efficiency
Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.6 V at -10 C (568.4 V string) and 41.57 V at -20 C (14 max).
20 Panels = 8,100 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,566 W PTC; NEC 690.8 OCPD floor is 21.64 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.23 * (1 + (-0.259/100) * (-10 - 25)) = 40.6 V | OCPD = 1.56 * 13.87 = 21.64 A
Inputs from CEC Modules.csv for JA Solar JAM54S31-405/MR: Voc=37.23 V, beta_Voc=-0.259%/C, Isc=13.87 A, STC=405.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (568.4 V); 20 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for JA Solar JAM54S31-405/MR?
Laboratory test ratings recorded for JA Solar JAM54S31-405/MR (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 378.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.23 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.87 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.21 V / 12.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.32% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM54S31-405/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (409 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM54S31-405/MR.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 307 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 409 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 511 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAM54S31-405/MR under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM54S31-400/MR | 400.0 W | 373.5 W | 37.07 V | 31.01 V | 21.05% |
| JA Solar JAM54S31-405/MR | 405.0 W | 378.3 W | 37.23 V | 31.21 V | 21.32% |
How Many JA Solar JAM54S31-405/MR Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAM54S31-405/MR (beta_Voc -0.259%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.57 V | 14 panels | 582.0 V | 24 panels |
| -10 C (14 F) | 40.6 V | 14 panels | 568.4 V | 24 panels |
| 0 C (32 F) | 39.64 V | 15 panels | 594.6 V | 25 panels |
| 25 C (77 F STC) | 37.23 V | 16 panels | 595.7 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM54S31-405/MR?
Closest cross-brand CEC competitors to JA Solar JAM54S31-405/MR matched near 405.0 W STC and 37.23 V Voc, led by CertainTeed CTM10405HC11-06.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10405HC11-06 CertainTeed |
405.0 W | Tie (0 W) | 37.23 V | 20.77% | 93.8% |
| AMPS Solar AMPS-405P-54BB AMPS Solar |
405.0 W | Tie (0 W) | 37.25 V | 20.88% | 94.2% |
| Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
405.0 W | Tie (0 W) | 37.2 V | 20.77% | 93.8% |
| Convalt Manufacturing LLC CVLT405-108M-BB Convalt Manufacturing LLC |
405.0 W | Tie (0 W) | 37.36 V | 20.88% | 92.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM54S31-405/MR?
Evaluate JA Solar JAM54S31-405/MR (405.0 W STC, 37.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM54S31-405/MR reaches 41.57 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM54S31-405/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM54S31-405/MR 8 kW Residential Fit
Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10405HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM54S31-405/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM54S31-405/MR panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM54S31-405/MR cold Voc rises from 37.23 V to 40.6 V (beta_Voc -0.259%/C), capping a 600 V string at 14 panels (568.4 V).
How much roof area does an 8 kW array of JA Solar JAM54S31-405/MR need?
An 8 kW DC system uses 20 JA Solar JAM54S31-405/MR modules (8,100 W STC / 7,566 W PTC), covering roughly 409 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does JA Solar JAM54S31-405/MR compare against CertainTeed CTM10405HC11-06?
JA Solar JAM54S31-405/MR outputs 405.0 W STC (37.23 V Voc, rank #8,961 of 21,677), while CertainTeed CTM10405HC11-06 delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)