JA Solar JAM5-72-185 is a 185.0 W STC (166.4 W PTC) Mono-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.49% efficiency, 45.47 V Voc at 25 C, and 50.56 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 185.0 W
- PTC Wattage
- 166.4 W
- Voc @ 25C
- 45.47 V
- Efficiency
- 14.49%
How Does JA Solar JAM5-72-185 Compare Against Peer CEC Listings?
Engineering position of JA Solar JAM5-72-185 (185.0 W STC) vs. Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, JA Solar JAM5-72-185 pairs typical 89.9% PTC-to-STC thermal output (166.4 W real-world rating) with 45.47 V nominal Voc. An 8 kW residential build (8,140 W DC, 7,322 W PTC) saves ~$2,037/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 offers a 185.0 W alternative.
Where Does JA Solar JAM5-72-185 Fall Across Listed CEC Models?
Plots JA Solar JAM5-72-185 at 185.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM5-72-185?
Benchmarks JA Solar JAM5-72-185 on STC wattage, thermal PTC/STC retention, and 14.49 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAM5-72-185?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM5-72-185 by JA Solar.
185.0 W STC · Higher Than 2.1%
185.0 W STC (-200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.49% Aperture Efficiency
Power density 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.56 V at -10 C (556.2 V string) and 52.02 V at -20 C (11 max).
44 Panels = 8,140 W STC
Occupies 56.2 m2 (605 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 8.38 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.47 * (1 + (-0.32/100) * (-10 - 25)) = 50.56 V | OCPD = 1.56 * 5.37 = 8.38 A
Inputs from CEC Modules.csv for JA Solar JAM5-72-185: Voc=45.47 V, beta_Voc=-0.32%/C, Isc=5.37 A, STC=185.0 W, Area=1.277 m2.
Result: 11 panels max on 600 V (556.2 V); 44 panels for 8 kW (605 sq ft).
What Are the Published CEC Specifications for JA Solar JAM5-72-185?
Laboratory test ratings recorded for JA Solar JAM5-72-185 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 166.4 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.47 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.0 V / 5.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.49% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM5-72-185 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (605 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM5-72-185.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 33 | 6.11 kW | 454 sq ft | $1,529 | $2,586 |
| 8 kW Class | 44 | 8.14 kW | 605 sq ft | $2,037 | $3,445 |
| 10 kW Class | 55 | 10.18 kW | 756 sq ft | $2,548 | $4,308 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAM5-72-185 under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM5-72-175 | 175.0 W | 157.2 W | 45.13 V | 36.6 V | 13.71% |
| JA Solar JAM5-72-180 | 180.0 W | 161.8 W | 45.3 V | 36.8 V | 14.1% |
| JA Solar JAM5-72-185 | 185.0 W | 166.4 W | 45.47 V | 37.0 V | 14.49% |
| JA Solar JAM5-72-190 | 190.0 W | 171.0 W | 45.64 V | 37.2 V | 14.88% |
| JA Solar JAM5-72-195 | 195.0 W | 175.6 W | 45.81 V | 37.4 V | 15.27% |
How Many JA Solar JAM5-72-185 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAM5-72-185 (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.02 V | 11 panels | 572.2 V | 19 panels |
| -10 C (14 F) | 50.56 V | 11 panels | 556.2 V | 19 panels |
| 0 C (32 F) | 49.11 V | 12 panels | 589.3 V | 20 panels |
| 25 C (77 F STC) | 45.47 V | 13 panels | 591.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5-72-185?
Closest cross-brand CEC competitors to JA Solar JAM5-72-185 matched near 185.0 W STC and 45.47 V Voc, led by Hanwha Qcells (Qidong) Co Ltd SF160-24-M185.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 Hanwha Qcells (Qidong) Co Ltd |
185.0 W | Tie (0 W) | 45.3 V | 14.49% | 89.5% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Hanwha Qcells (Qidong) Co Ltd |
185.0 W | Tie (0 W) | 45.3 V | 14.49% | 90.4% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185L Hanwha Qcells (Qidong) Co Ltd |
185.0 W | Tie (0 W) | 45.3 V | 14.49% | 89.5% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185L-B Hanwha Qcells (Qidong) Co Ltd |
185.0 W | Tie (0 W) | 45.3 V | 14.49% | 90.4% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM5-72-185?
Evaluate JA Solar JAM5-72-185 (185.0 W STC, 45.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5-72-185 reaches 52.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 605 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (605 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM5-72-185 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM5-72-185 8 kW Residential Fit
Needs 44 modules (605 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF160-24-M185.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 166.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM5-72-185 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM5-72-185?
Multiplying JA Solar JAM5-72-185's 5.37 A short-circuit current by 1.56 equals 8.38 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAM5-72-185 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.56 V cold Voc at 14 F and handles 5.37 A Isc; string inverters cap JA Solar JAM5-72-185 at 11 panels on 600 V.
Is JA Solar JAM5-72-185 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM5-72-185 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)