Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B is a 185.0 W STC (167.2 W PTC) Mono-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.49% efficiency, 45.3 V Voc at 25 C, and 50.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 185.0 W
- PTC Wattage
- 167.2 W
- Voc @ 25C
- 45.3 V
- Efficiency
- 14.49%
How Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Compare Against Peer CEC Listings?
How Hanwha Qcells (Qidong) Co Ltd Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B handles rooftop heat (167.2 W PTC), 8 kW sizing, and cold winter string voltage.
Hanwha Qcells (Qidong) Co Ltd builds the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (Mono-c-Si) as a compact residential or specialty off-grid module delivering 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). Compared against JA Solar JAM5-72-185 (185.0 W), this model holds typical 90.4% PTC-to-STC thermal output (167.2 W real-world rating). Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.16 A overcurrent floor served by a 15 A breaker.
Where Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Fall Across Listed CEC Models?
Where Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Percentile placement of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B across power density (144.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B specifications.
185.0 W STC · Higher Than 2.1%
185.0 W STC (-200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.49% Aperture Efficiency
Power density 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.44 V at -10 C (554.8 V string) and 51.9 V at -20 C (11 max).
44 Panels = 8,140 W STC
Occupies 56.2 m2 (605 sq ft) producing 7,357 W PTC; NEC 690.8 OCPD floor is 8.16 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.3 * (1 + (-0.324/100) * (-10 - 25)) = 50.44 V | OCPD = 1.56 * 5.23 = 8.16 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B: Voc=45.3 V, beta_Voc=-0.324%/C, Isc=5.23 A, STC=185.0 W, Area=1.277 m2.
Result: 11 panels max on 600 V (554.8 V); 44 panels for 8 kW (605 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 167.2 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.1 V / 5.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.49% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 33 | 6.11 kW | 454 sq ft | $1,529 | $2,586 |
| 8 kW Class | 44 | 8.14 kW | 605 sq ft | $2,037 | $3,445 |
| 10 kW Class | 55 | 10.18 kW | 756 sq ft | $2,548 | $4,308 |
Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?
All closely matched Hanwha Qcells (Qidong) Co Ltd wattages and cosmetic trims sharing the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M175B | 175.0 W | 158.0 W | 44.8 V | 36.0 V | 13.71% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M180B | 180.0 W | 162.6 W | 45.0 V | 36.0 V | 14.1% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B | 185.0 W | 167.2 W | 45.3 V | 36.1 V | 14.49% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M190B | 190.0 W | 171.8 W | 44.8 V | 35.8 V | 14.88% |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Modules Fit in a Cold-Weather String?
Maximum series module counts for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.9 V | 11 panels | 570.9 V | 19 panels |
| -10 C (14 F) | 50.44 V | 11 panels | 554.8 V | 19 panels |
| 0 C (32 F) | 48.97 V | 12 panels | 587.6 V | 20 panels |
| 25 C (77 F STC) | 45.3 V | 13 panels | 588.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Alternative CEC solar modules from competing brands near Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W), including JA Solar JAM5-72-185.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM5-72-185 JA Solar |
185.0 W | Tie (0 W) | 45.47 V | 14.49% | 89.9% |
| Hengdian Group DMEGC Magnetics Co Ltd DM185-M125-72 Hengdian Group DMEGC Magnetics Co Ltd |
185.0 W | Tie (0 W) | 45.0 V | 15.05% | 88.3% |
| Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-185 Jinzhou Jinmao Photovoltaic Technology |
185.0 W | Tie (0 W) | 44.47 V | 14.49% | 86.6% |
| AXITEC AC-190M/125-72S AXITEC |
190.0 W | +5.0 W | 45.23 V | 14.88% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B reaches 51.9 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 605 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (605 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B 8 kW Residential Fit
Needs 44 modules (605 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare JA Solar JAM5-72-185.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 167.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?
Multiplying Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B's 5.23 A short-circuit current by 1.56 equals 8.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.44 V cold Voc at 14 F and handles 5.23 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B at 11 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)