Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B — CEC Solar Module Specifications

Manufacturer: Hanwha Qcells (Qidong) Co Ltd Registry: CEC Verified Engineering Specification

Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B is a 185.0 W STC (167.2 W PTC) Mono-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.49% efficiency, 45.3 V Voc at 25 C, and 50.44 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
185.0 W
PTC Wattage
167.2 W
Voc @ 25C
45.3 V
Efficiency
14.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Compare Against Peer CEC Listings?

How Hanwha Qcells (Qidong) Co Ltd Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B handles rooftop heat (167.2 W PTC), 8 kW sizing, and cold winter string voltage.

Hanwha Qcells (Qidong) Co Ltd builds the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (Mono-c-Si) as a compact residential or specialty off-grid module delivering 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). Compared against JA Solar JAM5-72-185 (185.0 W), this model holds typical 90.4% PTC-to-STC thermal output (167.2 W real-world rating). Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.16 A overcurrent floor served by a 15 A breaker.

Where Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Fall Across Listed CEC Models?

Where Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanwha Qcells (Qid: 185.0 W

What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Percentile placement of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B across power density (144.9 W/m2), thermal retention, and nameplate STC wattage.

Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Engineering BenchmarksPercentile comparison of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage185.0 WPTC/STC Retention90.4%Module Efficiency14.49%

What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B specifications.

Rank #21,185 / 21,677

185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,423

14.49% Aperture Efficiency

Power density 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.44 V at -10 C (554.8 V string) and 51.9 V at -20 C (11 max).

8 kW Reference Array

44 Panels = 8,140 W STC

Occupies 56.2 m2 (605 sq ft) producing 7,357 W PTC; NEC 690.8 OCPD floor is 8.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.3 * (1 + (-0.324/100) * (-10 - 25)) = 50.44 V | OCPD = 1.56 * 5.23 = 8.16 A

Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B: Voc=45.3 V, beta_Voc=-0.324%/C, Isc=5.23 A, STC=185.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (554.8 V); 44 panels for 8 kW (605 sq ft).

What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B.

Official California Energy Commission (NREL SAM) test parameters for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 185.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 167.2 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.1 V / 5.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.49% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 33 6.11 kW 454 sq ft $1,529 $2,586
8 kW Class 44 8.14 kW 605 sq ft $2,037 $3,445
10 kW Class 55 10.18 kW 756 sq ft $2,548 $4,308

Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?

All closely matched Hanwha Qcells (Qidong) Co Ltd wattages and cosmetic trims sharing the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B architecture.

Sibling CEC listings grouped into the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanwha Qcells (Qidong) Co Ltd SF160-24-M175B 175.0 W 158.0 W 44.8 V 36.0 V 13.71%
Hanwha Qcells (Qidong) Co Ltd SF160-24-M180B 180.0 W 162.6 W 45.0 V 36.0 V 14.1%
Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B 185.0 W 167.2 W 45.3 V 36.1 V 14.49%
Hanwha Qcells (Qidong) Co Ltd SF160-24-M190B 190.0 W 171.8 W 44.8 V 35.8 V 14.88%

How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.3V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.9 V 11 panels 570.9 V 19 panels
-10 C (14 F) 50.44 V 11 panels 554.8 V 19 panels
0 C (32 F) 48.97 V 12 panels 587.6 V 20 panels
25 C (77 F STC) 45.3 V 13 panels 588.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Alternative CEC solar modules from competing brands near Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W), including JA Solar JAM5-72-185.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
JA Solar JAM5-72-185
JA Solar
185.0 W Tie (0 W) 45.47 V 14.49% 89.9%
Hengdian Group DMEGC Magnetics Co Ltd DM185-M125-72
Hengdian Group DMEGC Magnetics Co Ltd
185.0 W Tie (0 W) 45.0 V 15.05% 88.3%
Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-185
Jinzhou Jinmao Photovoltaic Technology
185.0 W Tie (0 W) 44.47 V 14.49% 86.6%
AXITEC AC-190M/125-72S
AXITEC
190.0 W +5.0 W 45.23 V 14.88% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Evaluate Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B (185.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B reaches 51.9 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 44 panels for an 8 kW build require 605 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (605 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B 8 kW Residential Fit

Needs 44 modules (605 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare JA Solar JAM5-72-185.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 167.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B?

Multiplying Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B's 5.23 A short-circuit current by 1.56 equals 8.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.44 V cold Voc at 14 F and handles 5.23 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B at 11 panels on 600 V.

Is Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.