AXITEC AC-190M/125-72S is a 190.0 W STC (170.6 W PTC) Mono-c-Si solar module ranking #21,132 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.88% efficiency, 45.23 V Voc at 25 C, and 51.61 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 190.0 W
- PTC Wattage
- 170.6 W
- Voc @ 25C
- 45.23 V
- Efficiency
- 14.88%
How Does AXITEC AC-190M/125-72S Compare Against Peer CEC Listings?
How AXITEC AXITEC AC-190M/125-72S handles rooftop heat (170.6 W PTC), 8 kW sizing, and cold winter string voltage.
AXITEC builds the AXITEC AC-190M/125-72S (Mono-c-Si) as a compact residential or specialty off-grid module delivering 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). Compared against Suntech Power STP190S-24/Ad (190.0 W), this model holds typical 89.8% PTC-to-STC thermal output (170.6 W real-world rating). Mid-range 45.23 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.6 A overcurrent floor served by a 15 A breaker.
Where Does AXITEC AC-190M/125-72S Fall Across Listed CEC Models?
Where AXITEC AC-190M/125-72S (190.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-190M/125-72S?
Percentile placement of AXITEC AC-190M/125-72S across power density (148.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for AXITEC AC-190M/125-72S?
Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-190M/125-72S specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
190.0 W STC · Higher Than 2.3%
190.0 W STC (-195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.88% Aperture Efficiency
Power density 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.61 V at -10 C (567.7 V string) and 53.43 V at -20 C (11 max).
43 Panels = 8,170 W STC
Occupies 54.9 m2 (591 sq ft) producing 7,336 W PTC; NEC 690.8 OCPD floor is 8.6 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.23 * (1 + (-0.403/100) * (-10 - 25)) = 51.61 V | OCPD = 1.56 * 5.51 = 8.6 A
Inputs from CEC Modules.csv for AXITEC AC-190M/125-72S: Voc=45.23 V, beta_Voc=-0.403%/C, Isc=5.51 A, STC=190.0 W, Area=1.277 m2.
Result: 11 panels max on 600 V (567.7 V); 43 panels for 8 kW (591 sq ft).
What Are the Published CEC Specifications for AXITEC AC-190M/125-72S?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-190M/125-72S.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 190.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 170.6 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.23 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.5 V / 5.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.403 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.88% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-190M/125-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-190M/125-72S (190.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 32 | 6.08 kW | 440 sq ft | $1,522 | $2,573 |
| 8 kW Class | 43 | 8.17 kW | 591 sq ft | $2,045 | $3,458 |
| 10 kW Class | 53 | 10.07 kW | 729 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-190M/125-72S architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-190M/125-72S | 190.0 W | 170.6 W | 45.23 V | 36.5 V | 14.88% |
| AXITEC AC-195M/125-72S | 195.0 W | 175.2 W | 45.44 V | 36.94 V | 15.27% |
How Many AXITEC AC-190M/125-72S Modules Fit in a Cold-Weather String?
Maximum series module counts for AXITEC AC-190M/125-72S from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.43 V | 11 panels | 587.7 V | 18 panels |
| -10 C (14 F) | 51.61 V | 11 panels | 567.7 V | 19 panels |
| 0 C (32 F) | 49.79 V | 12 panels | 597.5 V | 20 panels |
| 25 C (77 F STC) | 45.23 V | 13 panels | 588.0 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-190M/125-72S?
Alternative CEC solar modules from competing brands near AXITEC AC-190M/125-72S (190.0 W), including Suntech Power STP190S-24/Ad.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Suntech Power STP190S-24/Ad Suntech Power |
190.0 W | Tie (0 W) | 45.2 V | 14.88% | 90.3% |
| Suntech Power STP190S-24/Adb Suntech Power |
190.0 W | Tie (0 W) | 45.2 V | 14.88% | 90.4% |
| Seraphim Solar System CoLtd SRP-190-5MB Seraphim Solar System CoLtd |
190.0 W | Tie (0 W) | 45.1 V | 14.88% | 90.3% |
| Trina Solar TSM-190DA01A Trina Solar |
190.0 W | Tie (0 W) | 45.1 V | 15.05% | 90.2% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-190M/125-72S?
Evaluate AXITEC AC-190M/125-72S (190.0 W STC, 45.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-190M/125-72S reaches 53.43 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 43 panels for an 8 kW build require 591 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (591 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-190M/125-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-190M/125-72S 8 kW Residential Fit
Needs 43 modules (591 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Suntech Power STP190S-24/Ad.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 170.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-190M/125-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-190M/125-72S?
Multiplying AXITEC AC-190M/125-72S's 5.51 A short-circuit current by 1.56 equals 8.6 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can AXITEC AC-190M/125-72S pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.61 V cold Voc at 14 F and handles 5.51 A Isc; string inverters cap AXITEC AC-190M/125-72S at 11 panels on 600 V.
Is AXITEC AC-190M/125-72S eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-190M/125-72S rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)