Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 is a 185.0 W STC (165.6 W PTC) Mono-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.49% efficiency, 45.3 V Voc at 25 C, and 50.5 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 185.0 W
- PTC Wattage
- 165.6 W
- Voc @ 25C
- 45.3 V
- Efficiency
- 14.49%
How Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hanwha Qcells (Qidong) Co Ltd and peers, Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 stands 225.0 W below the 410.0 W Mono-c-Si median and typical 89.5% PTC-to-STC thermal output (165.6 W real-world rating). Sizing 6 kW (33 panels) to 10 kW (55 panels) yields $1,529-$2,548/yr in baseline US bill offset. Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 Fall Across Listed CEC Models?
Distribution marker showing Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 (185.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Dataset percentiles tracking Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Benchmark highlights for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
185.0 W STC · Higher Than 2.1%
185.0 W STC (-200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.49% Aperture Efficiency
Power density 144.9 W/m2 (5.42 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.5 V at -10 C (555.5 V string) and 51.99 V at -20 C (11 max).
44 Panels = 8,140 W STC
Occupies 56.2 m2 (605 sq ft) producing 7,286 W PTC; NEC 690.8 OCPD floor is 8.16 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.3 * (1 + (-0.328/100) * (-10 - 25)) = 50.5 V | OCPD = 1.56 * 5.23 = 8.16 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185: Voc=45.3 V, beta_Voc=-0.328%/C, Isc=5.23 A, STC=185.0 W, Area=1.277 m2.
Result: 11 panels max on 600 V (555.5 V); 44 panels for 8 kW (605 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Official CEC datasheet figures for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 165.6 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.1 V / 5.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.328 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.49% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 33 | 6.11 kW | 454 sq ft | $1,529 | $2,586 |
| 8 kW Class | 44 | 8.14 kW | 605 sq ft | $2,037 | $3,445 |
| 10 kW Class | 55 | 10.18 kW | 756 sq ft | $2,548 | $4,308 |
Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?
Consolidated Hanwha Qcells (Qidong) Co Ltd wattage variants sharing the Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M175 | 175.0 W | 156.4 W | 44.8 V | 36.0 V | 13.71% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M180 | 180.0 W | 161.0 W | 45.0 V | 36.0 V | 14.1% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 | 185.0 W | 165.6 W | 45.3 V | 36.1 V | 14.49% |
| Hanwha Qcells (Qidong) Co Ltd SF160-24-M190 | 190.0 W | 170.2 W | 44.8 V | 35.8 V | 14.88% |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 (50.5 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.99 V | 11 panels | 571.9 V | 19 panels |
| -10 C (14 F) | 50.5 V | 11 panels | 555.5 V | 19 panels |
| 0 C (32 F) | 49.01 V | 12 panels | 588.1 V | 20 panels |
| 25 C (77 F STC) | 45.3 V | 13 panels | 588.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Competing CEC solar panels closest to Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 in nameplate wattage and Voc, starting with JA Solar JAM5-72-185.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM5-72-185 JA Solar |
185.0 W | Tie (0 W) | 45.47 V | 14.49% | 89.9% |
| Hengdian Group DMEGC Magnetics Co Ltd DM185-M125-72 Hengdian Group DMEGC Magnetics Co Ltd |
185.0 W | Tie (0 W) | 45.0 V | 15.05% | 88.3% |
| Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-185 Jinzhou Jinmao Photovoltaic Technology |
185.0 W | Tie (0 W) | 44.47 V | 14.49% | 86.6% |
| AXITEC AC-190M/125-72S AXITEC |
190.0 W | +5.0 W | 45.23 V | 14.88% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 (185.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 reaches 51.99 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 605 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (605 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 8 kW Residential Fit
Needs 44 modules (605 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare JA Solar JAM5-72-185.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 165.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd SF160-24-M185?
Multiplying Hanwha Qcells (Qidong) Co Ltd SF160-24-M185's 5.23 A short-circuit current by 1.56 equals 8.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.5 V cold Voc at 14 F and handles 5.23 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 at 11 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-M185 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)