HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG is a 360.0 W STC (337.6 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.78% efficiency, 41.0 V Voc at 25 C, and 44.85 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 337.6 W
- Voc @ 25C
- 41.0 V
- Efficiency
- 19.78%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG Compare Against Peer CEC Listings?
How HD HYUNDAI ENERGY SOLUTIONS CO LTD HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG handles rooftop heat (337.6 W PTC), 8 kW sizing, and cold winter string voltage.
HD HYUNDAI ENERGY SOLUTIONS CO LTD builds the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG (Mono-c-Si) as a compact residential or specialty off-grid module delivering 197.8 W/m2 (0.13 percentage points below 19.91% CEC median). Compared against DualSun SAS DualSun 360M-120-00 (360.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Mid-range 41.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.47 A overcurrent floor served by a 20 A breaker.
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG Fall Across Listed CEC Models?
Where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Percentile placement of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG across power density (197.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Four critical engineering numbers homeowners and solar installers check first when reviewing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG specifications.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.78% Aperture Efficiency
Power density 197.8 W/m2 (0.13 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.85 V at -10 C (583.1 V string) and 45.94 V at -20 C (13 max).
23 Panels = 8,280 W STC
Occupies 41.9 m2 (451 sq ft) producing 7,765 W PTC; NEC 690.8 OCPD floor is 17.47 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.0 * (1 + (-0.268/100) * (-10 - 25)) = 44.85 V | OCPD = 1.56 * 11.2 = 17.47 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG: Voc=41.0 V, beta_Voc=-0.268%/C, Isc=11.2 A, STC=360.0 W, Area=1.82 m2.
Result: 13 panels max on 600 V (583.1 V); 23 panels for 8 kW (451 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 337.6 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.1 V / 10.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.78% (1.82 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG (360.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 333 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 451 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 549 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?
All closely matched HD HYUNDAI ENERGY SOLUTIONS CO LTD wattages and cosmetic trims sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350YG | 350.0 W | 328.0 W | 40.3 V | 33.6 V | 19.23% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355YG | 355.0 W | 332.8 W | 40.6 V | 33.9 V | 19.51% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG | 360.0 W | 337.6 W | 41.0 V | 34.1 V | 19.78% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365YG | 365.0 W | 342.4 W | 41.3 V | 34.3 V | 20.05% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370YG | 370.0 W | 347.2 W | 41.5 V | 34.6 V | 20.33% |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG Modules Fit in a Cold-Weather String?
Maximum series module counts for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.94 V | 13 panels | 597.2 V | 21 panels |
| -10 C (14 F) | 44.85 V | 13 panels | 583.1 V | 22 panels |
| 0 C (32 F) | 43.75 V | 13 panels | 568.8 V | 22 panels |
| 25 C (77 F STC) | 41.0 V | 14 panels | 574.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Alternative CEC solar modules from competing brands near HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG (360.0 W), including DualSun SAS DualSun 360M-120-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 360M-120-00 DualSun SAS |
360.0 W | Tie (0 W) | 40.9 V | 19.89% | 93.3% |
| DualSun SAS DualSun 360M-120-01 DualSun SAS |
360.0 W | Tie (0 W) | 40.9 V | 19.89% | 93.2% |
| CSI Solar Co Ltd CS3L-360P CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 40.6 V | 20.11% | 92.4% |
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG (360.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG reaches 45.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft).
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG 8 kW Residential Fit
Needs 23 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 360M-120-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG?
Multiplying HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG's 11.2 A short-circuit current by 1.56 equals 17.47 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.85 V cold Voc at 14 F and handles 11.2 A Isc; string inverters cap HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG at 13 panels on 600 V.
Is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)