Manufacturer: HD HYUNDAI ENERGY SOLUTIONS CO LTD Registry: CEC Verified Engineering Specification

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ is a 640.0 W STC (610.6 W PTC) Mono-c-Si solar module ranking #638 of 21,677 CEC listings (top 3.3%; higher than 96.7% of peers). It delivers 23.1% efficiency, 56.3 V Voc at 25 C, and 60.77 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
640.0 W
PTC Wattage
610.6 W
Voc @ 25C
56.3 V
Efficiency
23.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (Mono-c-Si) residential solar systems.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ delivers 231.0 W/m2 (3.19 percentage points above 19.91% CEC median) and strong 95.4% PTC-to-STC heat retention (#141 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 62.05 V per unit, capping 600 V circuits at 9 panels. Compare specs directly with Bluesun Solar CoLtd BSM640M10-78HNH (640.0 W).

Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Fall Across Listed CEC Models?

Comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (640.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (640.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHD HYUNDAI ENERGY : 640.0 W

What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Relative ranking of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ across nameplate watts, 95.4% PTC thermal ratio, and module aperture efficiency.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Engineering BenchmarksPercentile comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage640.0 WPTC/STC Retention95.4%Module Efficiency23.1%

What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Summary of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ output rank, 8 kW array size (13 panels), efficiency rating, and 600 V string limit.

Rank #638 / 21,677

Top 3.3% STC Output

640.0 W STC (+255.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #985

23.1% Aperture Efficiency

Power density 231.0 W/m2 (3.19 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.77 V at -10 C (546.9 V string) and 62.05 V at -20 C (9 max).

8 kW Reference Array

13 Panels = 8,320 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,938 W PTC; NEC 690.8 OCPD floor is 22.48 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.3 * (1 + (-0.227/100) * (-10 - 25)) = 60.77 V | OCPD = 1.56 * 14.41 = 22.48 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ: Voc=56.3 V, beta_Voc=-0.227%/C, Isc=14.41 A, STC=640.0 W, Area=2.77 m2.

Result: 9 panels max on 600 V (546.9 V); 13 panels for 8 kW (388 sq ft).

What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Complete CEC test sheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ including Isc (14.41 A), Voc (56.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 640.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 610.6 W (95.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 56.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.9 V / 13.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.227 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.1% (2.77 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.4 kW 298 sq ft $1,602 $2,709
8 kW Class 13 8.32 kW 388 sq ft $2,082 $3,521
10 kW Class 16 10.24 kW 477 sq ft $2,563 $4,334

Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HD HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ series guide.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T630NJ 630.0 W 600.9 W 55.9 V 46.5 V 22.74%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T635NJ 635.0 W 605.8 W 56.1 V 46.7 V 22.92%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ 640.0 W 610.6 W 56.3 V 46.9 V 23.1%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T645NJ 645.0 W 615.5 W 56.5 V 47.1 V 23.29%

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (56.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=56.3V and beta_Voc=-0.227%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 62.05 V 9 panels 558.4 V 16 panels
-10 C (14 F) 60.77 V 9 panels 546.9 V 16 panels
0 C (32 F) 59.5 V 10 panels 595.0 V 16 panels
25 C (77 F STC) 56.3 V 10 panels 563.0 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Four comparable CEC modules such as Bluesun Solar CoLtd BSM640M10-78HNH (640.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar CoLtd BSM640M10-78HNH
Bluesun Solar CoLtd
640.0 W Tie (0 W) 56.2 V 23.1% 95.2%
Hanersun Energy Co Ltd HN18N-78HT635W
Hanersun Energy Co Ltd
635.0 W -5.0 W 56.2 V 23.26% 95.0%
Hansol Technics Co Ltd HA635-AE-NNEA0
Hansol Technics Co Ltd
635.0 W -5.0 W 56.1 V 22.92% 95.4%
New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10
New East Solar Energy (Cambodia) CoLtd
635.0 W -5.0 W 56.1 V 22.92% 95.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (640.0 W STC, 56.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ reaches 62.05 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Bluesun Solar CoLtd BSM640M10-78HNH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 610.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ panels fit on a 600 V winter solar string?

At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ cold Voc rises from 56.3 V to 60.77 V (beta_Voc -0.227%/C), capping a 600 V string at 9 panels (546.9 V).

How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ need?

An 8 kW DC system uses 13 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ modules (8,320 W STC / 7,938 W PTC), covering roughly 388 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ compare against Bluesun Solar CoLtd BSM640M10-78HNH?

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ outputs 640.0 W STC (56.3 V Voc, rank #638 of 21,677), while Bluesun Solar CoLtd BSM640M10-78HNH delivers 640.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.