HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ is a 600.0 W STC (560.1 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 21.74% efficiency, 54.2 V Voc at 25 C, and 58.87 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 560.1 W
- Voc @ 25C
- 54.2 V
- Efficiency
- 21.74%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ Compare Against Peer CEC Listings?
Solar engineering breakdown for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from HD HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ stands 190.0 W above the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,502-$2,553/yr in baseline US bill offset. Higher 54.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ Fall Across Listed CEC Models?
Distribution marker showing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ (600.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Dataset percentiles tracking HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Benchmark highlights for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.74% Aperture Efficiency
Power density 217.4 W/m2 (1.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.87 V at -10 C (588.7 V string) and 60.2 V at -20 C (9 max).
14 Panels = 8,400 W STC
Occupies 38.6 m2 (416 sq ft) producing 7,841 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 54.2 * (1 + (-0.246/100) * (-10 - 25)) = 58.87 V | OCPD = 1.56 * 13.71 = 21.39 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ: Voc=54.2 V, beta_Voc=-0.246%/C, Isc=13.71 A, STC=600.0 W, Area=2.76 m2.
Result: 10 panels max on 600 V (588.7 V); 14 panels for 8 kW (416 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Official CEC datasheet figures for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 560.1 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 54.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.2 V / 12.95 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.246 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.74% (2.76 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Bifacial glass-glass |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 297 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 416 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 505 sq ft | $2,553 | $4,317 |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ (58.87 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 60.2 V | 9 panels | 541.8 V | 16 panels |
| -10 C (14 F) | 58.87 V | 10 panels | 588.7 V | 16 panels |
| 0 C (32 F) | 57.53 V | 10 panels | 575.3 V | 17 panels |
| 25 C (77 F STC) | 54.2 V | 11 panels | 596.2 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Competing CEC solar panels closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ in nameplate wattage and Voc, starting with JA Solar JAM72D40-600/MB-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM72D40-600/MB-US JA Solar |
600.0 W | Tie (0 W) | 54.3 V | 23.81% | 95.1% |
| FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600 FS GREEN ENERGIES PRIVATE LIMITED |
600.0 W | Tie (0 W) | 53.7 V | 23.44% | 95.1% |
| AMPS Solar AMPS-600N-144SW AMPS Solar |
600.0 W | Tie (0 W) | 53.3 V | 23.44% | 95.0% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
600.0 W | Tie (0 W) | 53.05 V | 23.26% | 95.5% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ (600.0 W STC, 54.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ reaches 60.2 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 416 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ 8 kW Residential Fit
Needs 14 modules (416 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare JA Solar JAM72D40-600/MB-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 560.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ?
Multiplying HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 58.87 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ at 10 panels on 600 V.
Is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)